ABSTRACT
Optical coherence tomography is a non-contact optical device that provides magnified and detailed images of internal structures of ocular tissues with a noninvasive, high resolution exam for evaluation of the anterior segment and ocular surface. At the present time it has become a crucial tool in clinical practice. We review the fundamentals and clinical applications, considering the advantages and limitations, describing its role in the diagnosis, surgical planning and clinical evaluation of the anterior segment.
REFERENCES
Huang D, Swanson EA, Lin CP, Schuman JS, Stinson WG, Chang W, et al. Optical coherence tomography. Science 1991; 254: 1178-81.
Izatt JA, Hee MR, Swanson EA, et al. Micrometer scale resolution imaging of the anterior eye in vivo with optical coherence tomography. Arch Ophthalmol 1994; 112(12): 1584-9.
Van den Berg TJ, Spekreijse H. Near infrared light absorption in the human eye media. Vision Res 1997; 37(2): 249-53.
Huang D, Li Y, Radhakrishnan S. Optical coherence tomography of the anterior segment of the eye. Ophthalmol Clin North Am 2004; 17(1): 1-6.
Cortés DE, et al. Tomografía de coherencia óptica y segmento anterior. Panamericana; 2012. pp. 5-10.
The definition and classification of dry eye disease: report of the definition and classification subcommittee of the international dry eye WorkShop. The Ocular Surface 2007; 5(2): 75-92.
Czajkowski G, Kaluzny BJ, Laudencka A, Malukiewicz G, Kaluzny JJ. Tear meniscus measurement by spectral optical coherence tomography. Optometry and Vision Science 2012; 89(3): 336-42.
Bujak MC, Yiu S, Zhang X, Li Y, Huang D. Serial measurement of tear meniscus by FD-OCT after instillation of artificial tears in patients with dry eyes. Ophthalmic Surgery Lasers and Imaging 2011; 42(4): 308-13.
Li H, Leung CK, Wong L, et al. Comparative study of central thickness measurement with slit-lamp optical coherence tomography and Visante optical coherence tomography. Ophthalmology 2008; 115(5): 796-801.e2.
Goldsmith JA, Li Y, Chalita MR, Westphal V, Patil CA, Rollins AM, et al. Anterior chamber width measurement by high-speed optical coherence tomography. Ophthalmology 2005; 112: 238-44.
Doors M, Cals DW, Berendschot TT, de Brabander J, Hendrikse F, Webers CA, et al. Influence of anterior chamber morphometrics on endothelial cell changes after phakic intraocular lens implantation. J Cataract Refract Surg 2008; 34: 2110-8.
Guell JL, Morral M, Gris O, Gaytan J, Sisquella M, Manero F. Evaluation of Verisyse and Artiflex phakic intraocular lenses during accommodation using Visante optical coherence tomography. J Cataract Refract Surg 2007; 33: 1398-404.
Mohamed S, Lee GK, Rao SK, Wong AL, Cheng AC, Li EY, et al. Repeatability and reproducibility of pachymetric mapping with Visante anterior segment-optical coherence tomography. Invest Ophthalmol Vis Sci 2007; 48: 5499-504.
Li Y, Shekhar R, Huang D. Corneal pachymetry mapping with high speed optical coherence tomography. Ophthalmology 2006; 113: 792-9.
Kucumen RB, Dinc UA, Yeneral NM, Gorgun E, Alimgil ML. Immediate evaluation of the flaps created by femtosecond laser using anterior segment optical coherence tomography. Ophthalmic Surg Lasers Imaging 2009; 40: 2541-4.
Stahl JE, Durrie DS, Schwendeman FJ, Boghossian AJ. Anterior segment OCT analysis of thin IntraLase femtosecond flaps. J Refract Surg 2007; 23: 555-8.
Von Jagow B, Kohnen T. Corneal architecture of femto-second laser and microkeratome flaps imaged by anterior segment optical coherence tomography. J Cataract Refract Surg 2009; 35: 35-41.
Rosas C, Li Y, Huang D. High-resolution optical coherence tomography visualization of LASIK flap displacement. J Cataract Refract Surg 2009; 35: 1640-2.
Nguyen P, Chopra V. Applications of optical coherence tomography in cataract surgery. Curr Opin Ophthalmol 2013; 24: 47-52.
Dupont-Monod S, Labbe A, Fayol N, Chassignol A, Bourges JC, Baudoin C. In vivo architectural analysis of clear corneal incisions using anterior segment optical coherence tomography. J Cataract Refract Surg 2009; 35: 444-50.
Choi CY, Youm DJ, Kim MJ, Tchah H. Changes in central corneal thickness of preserved corneas over time measured using anterior segment optical coherence tomography. Cornea 2000; 28: 536-40.
Wylegala E, Nowinska A. Usefulness of anterior segment optical coherence tomography in Descemet membrane detachment. Eur J Ophthalmol 2009; 19: 723-8.
Garcia JP Jr, de la Cruz J, Rosen RB, Buxton DF. Imaging implanted keratoprostheses with anterior segment optical coherence tomography and ultrasound biomicroscopy. Cornea 2008; 27: 180-8.
Wylegala E, Dobrowolski D, Nowinska A, Tarnawska D. Anterior segment optical coherence tomography in eye injuries. Graefes Arch Clin Exp Ophthalmol 2009; 247: 451-55.
Rabinowitz Y. Keratoconus. Surv Opthalmol 1998; 42: 297-319.
Li Y, Meisler D, Tang M, et al. Keratoconus diagnosis with optical coherence tomography pachymetry mapping. Ophthalmology 2008; 115(12): 2159-66.
Lai MM, Tang M, Andrade EM, Li Y, Khurana RN, Song JC, et al. Optical coherence tomography to assess intrastromal corneal ring segment depth in keratoconic eyes. J Cataract Refract Surg 2006; 32: 1860-5.
Wirbelauer C, Winkler J, Scholz C, Haberle H, Pham DT. Experimental imaging of intracorneal ring segments with optical coherence tomography. J Refract Surg 2003; 19: 367-71.
Vanathi M, Behera G, Vengayil S, Panda A, Khokhar S. Intracameral SF6 injection and anterior segment OCT-based documentation for acute hydrops management in pellucid marginal degeneration. Cont Lens Anterior Eye 2008; 31: 164-6.
Vajzovic L, Karp CL, Haft P, Abou M, Dubovy S, Hurmeric V, et al. Ultra high-resolution anterior segment optical coherence tomography in the evaluation of anterior corneal dystrophies and degenerations. Ophthalmology 2011; 118: 1291-6.
Abou M, Karp CL, Perez V, Hofmann R, Ventura R, Chang V, et al. Diagnosis and management of conjunctival and corneal intraepithelial neoplasia using ultra high-resolution optical coherence tomography. Ophthalmology 2011; 118: 1531-7.
Bianciotto C, Shields C, Guzman J, Romanelli-Gobbi M, Mazzuca D, Green R, et al. Assessment of anterior segment tumors with ultrasound biomicroscopy versus anterior segment optical coherence tomography in 200 cases. Ophthalmology 2011; 118: 1297-302.
Radhakrishnan S, See J, Smith SD, Nolan WP, Ce Z, Friedman DS, et al. Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography. Invest Ophthal Vis Sci 2007; 48: 3663-8.
Kim DY, Sung KR, Kang SY, Cho JW, Lee KS, Park SB, et al. Reproducibility of anterior chamber angle by anterior segment OCT. Acta Ophthalmol 2009 Nov 19. Retrieved online.
Radhakrishnan S, Huang D, Smith SD. Optical coherence tomography imaging of the anterior chamber angle. Ophthalmol Clin North Am 2005; 18(3): 375-81, vi.
Nolan NP, See JL, Chew PT, Friedman DS, Smith SD, Radhakrishnan S, et al. Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes. Ophthalmology 2007; 114: 33-9.
Sakata LM, Lavanya R, Friedman DS, Aung HT, Gao H, Kumar RS, et al. Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle. Ophthalmology 2008; 115: 769-74.
Dada T, Sihota R, Gadia R, Aggarwal A, Mandal S, Gupta V. Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment. J Cataract Refract Surg 2007; 33: 837-40.
Sarodia U, Sharkawi E, Hau S, Barton K. Visualization of aqueous shunt position and patency using anterior segment optical coherence tomography. Am J Ophthalmol 2007; 143: 1054-6.
Singh M, Chew PT, Friedman DS, Nolan WP, See JL, Smith SD, et al. Imaging of trabeculectomy blebs using anterior segment optical coherence tomography. Ophthalmology 2007; 114: 47-53.
Ciancaglini M, Carpineto P, Agnifili L, Nubile M, Lanzini M, Fasanella V, et al. Filtering bleb functionality: a clinical anterior segment optical coherence tomography and in vivo confocal microscopy study. J Glaucoma 2008; 17: 308-17.