2005, Number 4
<< Back Next >>
Med Int Mex 2005; 21 (4)
Ambulatory blood pressure readings. Its clinical usefulness
Fonseca RS, Parra CJZ
Language: Spanish
References: 54
Page: 282-290
PDF size: 120.47 Kb.
ABSTRACT
Inherent inaccuracy of the auscultatory technique, mercury sphygmomanometers banned in some states and hospitals, and the development of electronic devices to measure blood pressure have all led to the creation of other measurement techniques for the diagnosis and follow-up of arterial hypertension. Blood pressure measurements with automatic devices allow the collection of multiple readings outside the office, that is, at home or at work. This method is known as ambulatory measurement, and it includes two techniques: self-measurement and 24-hour ambulatory readings. These two procedures provide more precise and accurate blood pressure readings and have shown better association with the presence and development of target organ damage, as well as prediction of cardiovascular mortality. For almost 10 years several international organisms have designed and published recommendations for their application in the clinical setting; main indications for ambulatory blood pressure monitoring are white coat hypertension and assessment of antihypertensive treatment. The most important features of both techniques are described in this paper, along with their usefulness in evaluating a patient with persistent high blood pressure readings, using the auscultatory method.
REFERENCES
Lewington S, Clarke R, Qizilbash N, Prospective Studies Collaboration. Age-specific relevance of usual blood pressure to vascular mortality: a meta-analysis of individual data for one million adults in 61 prospective studies. Lancet 2002;360:1903-13.
Pickering TG, Davidson K, Gerin W, Schwartz JE. Masked hypertension. Hypertension 2002;40:795-6.
Fonseca-Reyes S, Parra-Carrillo JZ. Diagnóstico de hipertensión arterial. Más allá de la medición convencional. Nefrol Mex 2001;21(4):199-206.
Bailey RH, Bauer JH. A review of common errors in the indirect measurement of blood pressure. Arch Intern Med 1993;153:2741-8.
Baker RH, Ende J. Confounders of auscultatory blood pressure measurement. J Gen Intern Med 1995;10:223-31.
Campbell N, McKay D. Accurate blood pressure measurement: Why does it matter? CMAJ 1999;161:277-8.
Mansoor G. A practical approach to persistent elevation of blood pressure in the hypertension clinic. Blood Press Monit 2003;8:97-100.
Parati G, Grzegorz B, Mancia G. Blood pressure measurement in research and in clinical practice: recent evidence. Curr Opin Nephrol Hypertens 2004;13:343-57.
Stergiou GS, Voutsa AV, Achimastos AD, Mountokalakis TD. Home self-monitoring of blood pressure: is fully automated oscillometric technique as good as conventional stethoscopic technique? Am J Hypertens 1997;10:428-33.
Campbell NR, Abbot D, Bass M, et al. Self-measurement of blood pressure: recommendations of the Canadian Coalition for High Blood Pressure Prevention and Control. Can J Cardiol 1995;11(Suppl H):5H-10H.
Anwar YA, Glacco S, McCabe EJ, et al. Evaluations of the efficacy of the Omron HEM 737 IntelliSense device for use on adults according to the recommendations of the Association for the Advancement of Medical Instrumentation. Blood Press Monit 1998;3:261-6.
Fonseca RS, Parra JZ, García de Alba JE. La medición auscultatoria de la presión arterial. Investigación en Salud 1999;3(1):188-96.
Yarows SA, Julius S, Pickering T. Home blood pressure monitoring. Arch Intern Med 2000;160:1251-7.
O’Brien E, Asmar R, Beilin L, et al. European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens 2003;21:821-48.
Fonseca-Reyes S, García de Alba-García J, Parra-Carrillo JZ, Paczka-Zapata JA. Effect of standard cuff on blood pressure readings in patients with obese arms. How frequent are arms of a “large circumference”? Blood Press Monit 2003;8:101-6.
European Society of Hypertension. URL: http//www.eshonline.org/newsletter/2002/ Newsletter_nr12.pdf
British Hypertension Society. URL: http://www.hyp.ac.uk/bhs/bp_monitors/ automatic.htm
O’Brien E. Waeber B, Parati G, Staessen G, Myers MG, on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring. Blood pressure measuring devices: recommendations of the European Society of Hypertension. BMJ 2001;322:531-6.
Pickering TG, Hall JE, Appel LJ, et al. Recommendations for blood pressure measurement in humans and experimental animals. Part 1: blood pressure measurement in humans. Hypertension 2005;45:142-61.
Mengden T, Hernandez-Medina RM, et al. Reliability of reporting self-measured blood pressure values by hypertensive patients. Am J Hypertens 1998;11:1413-7.
Chobanian AV, Bakris GL, Black HR, National High Blood Pressure Education Program Coordinating Committee. The Seventh Report of the Joint National Committee on Prevention, Detection, and Treatment of High Blood Pressure: the JNC 7 report. JAMA 2003;289(19):2560-72.
Rickerby J. The role of home blood pressure measurement in managing hypertension: an evidence-based review. J Hum Hypertens 2002;16:469-72.
Mengden T, Chamontin B, Pong Chau NG, et al. User procedure for self-measurement of blood pressure. First International Consensus Conference on Self Blood Pressure Measurement. Blood Press Monit 2000;5:111-29.
Sakuma M, Imai Y, Nagai K, et al. Reproducibility of home blood pressure measurements over a 1-year period. Am J Hypertens 1997;10:798-803.
Kjeldsen SE, Moan A, Petrin J, et al. Evaluation of self-measured home vs clinic intraarterial blood pressure. Blood Press 1993;2(1):28-34.
Fonseca-Reyes S, Parra-Carrillo JZ, García de Alba-García JE. Utilidad de automedición de presión arterial para identificar la hipertensión arterial. Validación con monitoreo ambulatorio. III Latin-American Congress of Hypertension. Caracas, Venezuela. Arch Venez Farmacol Terap 2000;1:42.
Zaruke KB, Feagan BG, Mahon JL, Feldman RD. A randomized study comparing a patient-directed hypertension management strategy with usual office-based care. Am J Hypertens 1997;10:58-67.
Appel LJ, Stason WB. Ambulatory blood pressure monitoring and blood pressure self-measurement in the diagnosis and management of hypertension. Ann Intern Med 1993;118:867-82.
Abe H, Yokouchi M, Nagata Sl. Relation of office and home blood pressure to left ventricular hypertrophy and performance in patients with hypertension. High Blood Press 1992;1:279-85.
Julius S, Mejía A, Jones K. “White coat” versus “sustained” borderline hypertension in Tecumseh, Michigan. Hypertension 1990;16:617-23.
Bobrie G, Chatellier G, Genes N, et al. Cardiovascular prognosis of “masked hypertension” detected by blood pressure self-measurement in elderly treated hypertensive patients. JAMA 2004;291:1342-9.
Tsuji I, Imai Y, Nagai K, et al. Proposal of reference values for home blood pressure measurement: prognostic criteria based on a prospective observation of the general population in Ohasama, Japan. Am J Hypertens 1997;10:409-18.
White WB. Ambulatory blood pressure monitoring in clinical practice. N Engl J Med 2003;348:2377-8.
Bur A, Herkner H, Vicek M, et al. Classification of blood pressure levels by ambulatory blood pressure monitoring in a hypertensive population. Hypertension 2002;40:817-22.
Clement DL, De Buyzere M, De Bacquer D, et al. Prognostic value of ambulatory blood-pressure recording in patients with treated hypertension. N Engl J Med 2003;348:2407-15.
White WB. Clinical utility of ambulatory blood pressure: perspectives for national insurance coverage. Blood Press Monit 2002;7:27-31.
Myers MG, Haynes RB, Rabkin SW. Canadian hypertension society guidelines for ambulatory blood pressure monitoring. Am J Hypertens 1999;12:1149-57.
McGrath BP, on behalf of the National Blood Pressure Advisory Committee of the National Heart Foundation of Australia. Ambulatory blood pressure monitoring. MJA 2002;176:588-92.
Mancia G, Parati G. Ambulatory blood pressure monitoring and organ damage. Hypertension 2000;36(5):894-900.
Kario K, Pickering TG, Umeda Y. Morning surge in blood pressure as a predictor of silent and clinical cerebrovascular disease in elderly hypertensives: a prospective study. Circulation 2003;107:1401-6.
Ohkubo T, Imai Y, Tsuji I, et al. Relation between nocturnal decline in blood pressure and mortality. The Ohasama Study. Am J Hypertens 1997;10:1201-7.
Kario K, Shimada K, Pickering TG. Abnormal nocturnal blood pressure falls in elderly hypertension: clinical significance and determinants. J Cardiovasc Pharmacol 2003;41(Suppl 1):S61-S66.
Palatini P. Limitations of ambulatory blood pressure monitoring. Blood Press Monit 2001;6:221-4
Stegiou GS, Efstathiou SP, Skeva II. Comparison of the smoothness index, the trough:peak ratio and the morning:evening ratio in assessing the features of the antihypertensive drug effect. J Hypertens 2003;21:913-20.
Fonseca-Reyes S, Parra-Carrillo JZ, Chávez-Michel J. Hipertensión de la bata blanca. Su significado en el ambiente clínico. Med Intern Mex 1999;15(6):264-8.
Fonseca-Reyes S, Parra-Carrillo J, García de Alba-García J, González-Alvarez J. Hypertension diagnosis by clinic blood pressure and by ambulatory monitoring in primary care facility. Am J Hypertens 2001;14(4) part 2:40.
Pickering TG. Future developments in ambulatory blood pressure monitoring and self-blood pressure monitoring in clinical practice. Blood Press Monit 2002;7:21-25.
Fonseca-Reyes S. Comparación del modelo de automedición con el convencional para confirmar o excluir hipertensión arterial estadio 1 con validación por monitoreo ambulatorio en un primer nivel de atención médica. [Tesis recepcional]. Guadalajara: Universidad de Guadalajara, 1999.
Bidlingmeyer I, Burnier M, Bidlingmeyer M, et al. Isolated office hypertension: a prehypertensive state? J Hypertens 1996;14(3):327-32.
Fonseca-Reyes S, Parra-Carrillo J, García de Alba, García JE. Evolution of blood pressure in white coat hypertension patients evaluated with ambulatory monitoring. [Abstract] American Society of Hypertension, Eighteenth Annual Scientific Meeting. Am J Hypertens 2003;16(5):48A.
Fagard RH, Staessen JA, Thijs L. Response to antihypertensive therapy in older patients with sustained and nonsustained systolic hypertension: Systolic Hypertension in Europe (Syst-Eur) Trial Investigators. Circulation 2000;102:1139-44.
Kazuomi K, Pickering T. White-coat hypertension or white-coat hypertension syndrome: which is accompanied by target organ damage? Arch Intern Med 2000;160(22):3497-8.
Fonseca-Reyes S, Zúñiga-Sedano G, Parra-Carrillo JZ. Estudio comparativo de la disfunción diastólica y masa ventricular en pacientes con hipertensión arterial e hipertensión de la bata blanca. IX Congreso Nacional de Cardiología. Puerto Vallarta Jalisco. (Abstract) Rev Mex Cardiol 2000;11(3):17-18.
Palatini P. Too much of a good thing? A critique of overemphasis on the use of ambulatory blood pressure monitoring in clinical practice. J Hypertens 2002;20:1917-23.