Self-monitoring of blood glucose levels provides diabetic patients with a prompt method of measuring their blood glucose concentration, as opposed to conventional laboratory measurements. Frequent testing aids patients in the prevention and detection of hyper or hypoglycemia events. Only invasive and minimally invasive glucose sensors are currently commercially available. However, during the last couple of decades, work towards the development of a non-invasive glucose monitor has increased significantly among research groups with motivating results. Many techniques have been studied and implemented, each with their particular advantages and challenges. This paper presents a qualitative review of different technologies of non-invasive glucose sensors: spectroscopy-based methods, transdermal extraction-based methods, fluorescence, electromagnetic variations and polarimetry. This study identifies strengths and opportunities of currently available glucose monitoring techniques, as well as main characteristics and performance variables for an ideal non-invasive monitor. The most promising approaches towards the development of a truly non-invasive and clinically accurate glucose sensor are discussed.
REFERENCES
Ferrante AC, Wolf B. Current development in non-invasive glucose monitoring. Medical Engineering & Physics 2008; 30: 541-549.
Vesper HW, Myers GL. Approaches for improving glucose monitor measurements for self-monitoring of blood glucose: from measurement harmonization to external quality assessment programs. Journal of Diabetes Science and Technology 2007; 1(2): 2964-2967.
Thennadil SN, Rennert JL, Wenzel BJ, Hazen KH, Ruchti TL, Block MB. Comparison of glucose concentration in interstitial fluid, and capillary and venous blood during rapid changes in blood glucose levels. Diabetes Technology & Therapeutics, Sept. 2001.
Krogstad AL, Jansson PA, Gisslén P, Lönnroth P. Microdialysis methodology for the measurement of dermal interstitial fluid in humans. British Journal of Dermatology June 1996; 134(6):1005-1012.
Tonyushkina K, Nichols J. Glucose meters: a review of the technical challenges to obtaining accurate results. Journal of Diabetes Science and Technology July 2009; 3(4): 971-980.
Ellis DI, Goodacre R. Metabolic fingerprinting in disease diagnosis: biomedical applications of infrared and Raman spectroscopy. Analyst 2006; 131: 875-885.
Mendelson Y, Clermont AC, Peura RA, Lin B. Blood glucose measurement by multiple attenuated total reflection and infrared absorption spectroscopy. IEEE Transaction on Biomedical Engineering 1990; 37: 458-465.
Biomedical Photonics Handbook. 1st ed., Duke University, Durham, NC, 2003.
Yamakoshi Y, Ogawa M, Yamakoshi T, Satoh M, Nogawa M, Tanaka S, Tamura T, Rolfe P, Yamakoshi K. A new non-invasive method for measuring blood glucose using instantaneous differential near infrared spectrophotometry. 29th Annual International Conference of the IEEE, Lyon, France Aug, 2007: 2964-2967.
Ishizawa H, Muro A, Takano T, Honda K, Kanai H. Non-invasive blood glucose measurement based on ATR infrared spectroscopy. SICE Annual Conference 2008: 321-324.
Tenhunen J, KopolaH, Myllylä R. Non-invasive glucose measurement based on selective near infrared absorption; requirements on instrumentation and spectral range. Measurement 1998; 24: 173-177.
Ogawa M, Yamakoshi Y, Satoh M, Nogawa M, Yamakoshi T, Tanaka S, Rolfe P, Tamura T, Yamakoshi K. Support vector machines as multivariate calibration model for prediction of blood glucose concentration using a new non-invasive optical method named pulse glucometry. Proceedings of the 29th Annual International Conference of the IEEE EMBS 2007; 29: 4561-4563.
Ham FM, Cohen GM, Cho B. Glucose sensing using infrared absorption spectroscopy and a hybrid artificial neural network. Annual International Conference of the IEEE Engineering in Medicine and Biology Society 1991; 13: 1574-1576.
Losoya-Leal A, Camacho-Leon S, Martinez-Chapa S. Design of a CMOS-MEMS diffraction grating for near-infrared spectroscopy of biomolecules. Proceeding of the 7th IEEE Conference on Electronics, Robotics and Automotive Mechanics (CERMA), Cuernavaca, Mexico, Oct. 2010: 737-740.
Martinez-Torteya A, Dieck-Assad G, Martinez-Chapa S, Camacho-Leon S. Modeling and simulation of a CMOS-MEMS infrared thermopile; Simulation: Transactions of the Society for Modeling and Simulation International, England, 2011 (in review).
Handapangoda CC, Premaratne M, Paganin DM. Simulation of a device concept for noninvasive sensing of blood glucose levels. Third International Conference on Information and Automation for Sustainability, 2007; 3: 31-34.
Ergin A, Thomas GA. Non-invasive detection of glucose in porcine eyes. Proceedings of the IEEE 31st Annual Northeast Bioengineering Conference 2005; 31: 246-247.
Stewart DA, Yuen JM, Shah N, Lyandres O, Yonzon CR, Glucksberg MR, Wals JT, Van Duyne RP. In vivo glucose measurement by surface-enhanced Raman spectroscopy. Analytical Chemistry 2006; 78: 7211-7215.
Enejder AMK, Scecina TG, Oh J, Wei-Chuan MH, Sasic S, Horowitz GL, Feld MS. Raman spectroscopy for noninvasive glucose measurements. Journal of Biomedical Optics 2005; 10: 1-10.
Ergin A, Vilaboy J, Tchouassi A, Greene R, Thomas GA. Detection and analysis of glucose at metabolic concentration using Raman spectroscopy. Proceedings of the IEEE 29th Annual Bioengineering Conference 2003; 29: 337-338.
Jossinet J, Trillaud C. Technical improvement of a dual frequency EIT tomography for bioelectrical tissue characterization. Proceedings of the IEEE/EMBS 14th Annual International Conference 1992; 14: 1712.
Amaral C, Brischwein M, Wolf B. Multiparameter techniques for non-invasive measurement of blood glucose. Sensors and Actuators 2009; 140: 12-16.
Caduff A, Hirt E, Feldman Y, Ali, Heinemann L. First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system. Biosensors & Bioelectronics 2003; 19: 209-217.
Buchert JM. Thermal emission sprectroscopy as a tool for non-invasive blood glucose measurements. Proceedings of the SPIE, 2004; 5566: 100-111.
Malchoff CD, Shoukri K, Landau JI, Buchert JM. A novel noninvasive blood glucose monitor. Diabetes Care 2002; 25(12): 2268-2275.
Sieg A, Guy RH, Delgado-Charro MB. Electroosmosis in transdermal iontophoresis: implications for noninvasive and calibration-free glucose monitoring. Biophysical Journal 2004; 87(5): 3344-3350.
Singh P, Maibach HI. Iontophoresis in drug delivery: basic principles and applications. Critical Reviews in Therapeutic Drug Carrier Systems 1994; 11: 161-213.
Singh P, Maibach HI. Iontophoresis: an alternative to the use of carriers in cutaneous drug delivery. Advanced Drug Delivery Reviews 1996; 18(3): 379-394.
Ching CTS, Buisson Y, Connolly P. The effect of pulsed bipolar dc on the simultaneous extraction of glucose and lactate by reverse iontophoresis. Sensors and Actuators B: Chemical 2008; 129(2): 504-509.
US Food and Drug Administration. Glucowatch G2 biographer -P990026/S0008, Device Approvals and Clearances, 2009. [Online]. Available: http://www.fda.gov/MedicalDevices/ProductsandMedicalProcedures/DeviceApprovalsandClearances/Recently-ApprovedDevices/ucm083294.htm
Kim DW, Kim HS, Lee DH, Kim HC. Importance of skin resistance in the reverse iontophoresis-based noninvasive glucose monitoring system. Engineering in Medicine and Biology Society. IEMBS ‘04. 26th Annual International Conference of the IEEE, 2004; 1: 2434-2437.
Kost J, Mitragotri S, Gabbay, Pishko M, Langer R. Transdermal monitoring of glucose and other analytes using ultrasound. Nat Med 2000; 6: 347-350.
Parnjape M, Garra J, Brida S, Schneider T, White R, Currie J. A PDMS dermal patch for non-intrusive transdermal glucose sensing. Sensors and Actuators A 2003;104:195-204.
Coulman SA, Antsey A, Gateley C, Morrisey A, McLoughlin P, Allender C. Microneedle mediated delivery of nanoparticles into human skin. International Journal of Pharmaceutics 2009; 366: 190-200.
Moschou EA, Sharma BV, Deo SK, Daunert S. Fluorescence glucose detection: advances toward the ideal in vivo biosensor. Journal of Fluorescence 2004; 14(5): 535-547.
Pickupa JC, Hussain F, Evans ND, Rolinski OJ, Birch DJS. Fluorescence-based glucose sensors. Biosensors and Bioelectronics 2005; 20: 2555-2565.
Evans NC, Gnudi L, Rolinski OJ, Birch DJS, Pickup JC. Non-invasive glucose monitoring by NAD(P)H autofluorescence spectroscopy in fibroblasts and adipocytes: A model for skin glucose sensing. Diabetes Technology & Therapeutics 2003; 5(5): 807-816.
Bland E. Nano ink “Tatoo” could monitor diabetes, 2009; [Online]. Available: http://dsc.discovery.com/news/2009/02/12/diabetes-tattoo.html
Van Haeringen NJ. Clinical biochemistry of tears. Survey of Ophthalmology 1981; 26(2): 84-96.
Badugu R, Lakowicz JR, Geddes CD. A glucose sensing contact lens: A Non-invasive technique for continuous physiological glucose monitoring. Journal of Fluorescence 2003; 13(5): 371-374.
Badugu R, Lakowicz JR, Geddes CD. A glucose-sensing contact lens: from bench top to patient. Current Opinion in Biotechnology 2005; 16: 100-107.
Gourzi M, Rouane A, Guelaz R, Alavi MS, McHugh MB, Nadi M. Non-invasive glycaemia blood measurements by electromagnetic sensor: study in static and dynamic blood circulation. J Med Eng Technol 2005; 29: 22-26.
Gourzi M, Rouane A, McHugh MB, Guelaz R, Nadi M. New biosensor for non invasive glucose concentration measurement. Sensors, Proceedings of IEEE 2003; 2: 1343-1347.
Cameron BD, Coté GL. Polarimetric glucose sensing in aqueous humor utilizing digital closed-loop control. Engineering in Medicine and Biology Society. Bridging Disciplines for Biomedicine. Proceedings of the 18th Annual International Conference of the IEEE, 1996; 1: 204-205.
Boeckle S, Rovati L, Ansari RR. Polarimetric glucose sensing using the Brewster-reflection off the eye lens: theoretical analysis. Proceedings of SPIE 2002; 4624: 160-164.
Rawer R, Stork W, Kreiner CF. Non-invasive polarimetric measurement of glucose concentration in the anterior chamber of the eye. Graefe’s Archive for Clinical and Experimental Ophthalmology 2004; 242(12): 1017-1023.
Coté GL, Fox MD, Northrop RB. Noninvasive optical polarimetric glucose sensing using a true phase measurement technique. IEEE Transactions on Biomedical Engineering 1992; 39(7): 752-756.