2010, Number 2
<< Back Next >>
Rev Mex Ing Biomed 2010; 31 (2)
Single channel abdominal ECG algorithm for real-time maternal and fetal heart rate monitoring
Arias-Ortega R, Gaitán-González MJ
Language: English
References: 18
Page: 111-119
PDF size: 249.05 Kb.
ABSTRACT
From a single channel abdominal ECG, a maternal (MHR) and fetalheart rate (FHR) detection method is proposed. This method is based on sequential processing: detection and cancellation of maternal QRS complexes, followed by fetal QRS complexes detection, involving hardware suitable processing techniques. The algorithm was tested on a group of 25 different gestational age pregnant women signals; its performance was assessed using detections obtained by another single channel method and an expert physician. Concordance was evaluated by Cohen’s kappa coefficient and sensitivity comparison was done by repeated measures ANOVA for method and gestational age (p ‹ 0.05). Sensitivity behavior against fetal SNR was obtained as well as temporal coincidence of fetal and maternal complexes. Both methods presented similar high Cohen’s kappa coefficients, with detection success rates superior to 97% and 88% for maternal and fetal complexes respectively, but for 38 weeks of pregnancy the proposed method had lower maternal success rate than reference one (90%, p › 0.05). Proposed algorithm may be implemented in an independent platform and only requires operator supervision at the beginning of the process.
REFERENCES
Arduini D, Rizzo G, Romanini C. Computerized analysis of fetal heart rate. Journal of Perinatal Medicine 1994; 22(suppl): 22-27.
Kosasa TS, Abou-Sayp FK, Gaylyn LM, Hale RW. Evaluation of the cost effectiveness of home monitoring uterine contractions. Obstetrics and Gynecology 1990; 76: 71-75.
Symonds EM, Sahota D, Chang A. Fetal electrocardiography. Imperial College press 2001.
Kanjilal PP, Palit S, Saha G. Fetal ECG extraction from singlechannel maternal ECG using singular value decomposition. IEEE Trans Biomed Eng 1997; 44: 51-59.
Vrins F, Jutten C, Verleysen M. Sensor array and electrode selection for non-invasive fetal electrocardiogram extraction by independent component analysis. Lecture Notes in Computer Science 2004; 3195: 1017-1024.
Widrow B, Glover JR, McCool J, Kaunitz J, Williams CS, Hearn RH et al. Adaptive noise cancelling: principles and applications. Proceedings of the IEEE 1975; 63: 1692-1716.
Abboud S, Beker A. An improved detection algorithm in fetal electrocardiography. J Electrocardiol 1989; 22(Suppl.): 238- 42.
Zarzoso V, Nandi AK. Noninvasive fetal electrocardiogram extraction: Blind separation versus adaptive noise cancellation. IEEE Transactions on Biomedical Engineering 2001; 48: 12-18.
Ibrahimy MI, Firoz A, Mohd Ali MA, Edmond Z. Real-time signal processing for fetal heart rate monitoring. IEEE transactions on biomedical engineering 2003; 50: 258-62.
Martens SMM, Rabotti C, Mischi M, Sluijter RJ. A robust fetal ECG detection method for abdominal recordings. Physiological Measurement 2007; 28: 373-388.
Gaitán MJ, Carrasco S, González CR, Yañez SO. Detección de onda R por diferenciación estadística del complejo QRS. IV Simposio del Departamento de Ciencias de la Salud Univ. Autónoma Metropolitana Iztapalapa 1998.
Guyton AC, Hall JE. Textbook of Medical Physiology. Philadelphia, PA: Saunders 1996.
Rodríguez R. Algoritmo para la construcción en tiempo real del cardiotacograma materno y fetal a partir del ECG abdominal. Master’s thesis, Universidad Autónoma Metropolitana Iztapalapa 1997.
Goldberger AL, Amaral LAN, Glass L, Hausdorff JM, IvanovPCh, Mark RG et al. Physiobank, physiotoolkit, and physionet: Components of a new research resource for complex physiologic signals. Available: http://circ.ahajournals.org/cgi/ content/full/101/23/e215.
CohenJ. A coefficient of agreement for nominal scales. Educ Psychol Meas 1960; 20: 37-36.
Sargolzaei S, Faez K, Sargolzaei A. Signal processing based techniques for fetal electrocardiogram extraction, BioMedical Engineering and Informatics: New Development and the Future - Proceedings of the 1st International Conference on BioMedical Engineering and Informatics, BMEI 2008; 2: 492- 496.
Solum T, Ingermarsson I, Nygren A. The accuracy of abdominal ECG for fetal electronic monitoring. Journal of Perinatal Medicine 1980; 8(3): 142-149.
Matonia A, Kupka T, Jezewski J, Horoba K, Wrobel J, Gacek A. The influence of coincidence of fetal and maternal QRS complexes on fetal heart rate reliability. Medical and Biological Engineering and Computing 2006; 44(5): 393-403.