ABSTRACT
Background: Intraanesthetic monitoring of high-risk surgery requires the presence of a central catheter usually placed via subclavian puncture following anatomic reference points. This procedure is technically complex, is done blindly, and is not without complications. It has been reported that with the use of ultrasound guidance the puncture site in the vein can be easily identified and the catheter can be safely inserted for monitoring. The purpose of this study is to determine the reproducibility of ultrasound-guided subclavian puncture and report the advantages of the procedure.
Methods: We conducted a prospective study in patients undergoing surgery for cancer and who are candidates for intraanesthetic monitoring. The catheter was placed via an ultrasound-guided subclavian puncture with a high-resolution linear transducer (6-13 MHz color Doppler) minutes before surgery and with the patient under anesthesia. The transducer was placed in the subclavian region identifying the subclavian artery and subclavian vein. Puncture was at one side of the transducer, and identification was made of the trocar on the ultrasound screen guiding it towards the subclavian vein. We evaluated the number of attempts, success rate and complications.
Results: There were 16 patients. Puncture was successful on the first attempt in 14 (87.5%) punctures. In two punctures it was successful during the second attempt, and all had a central catheter in place. The average time of puncture was 5 min. There were no complications.
Conclusions: Ultrasound-guided subclavian puncture is an alternative to central catheter placement. Time involved is minimal and it ensures adequate placement. There were no complications in this series.
REFERENCES
McGee DC, Gould MK. Current concepts: preventing complications of central venous catheterization. N Engl J Med 2003;348:1123-1133.
Mermel LA, Farr BM, Sherertz RJ, Raad II, O´Grady N, Harris JS, et al. Guidelines for the management of intravascular catheter-related infections. Clin Infect Dis 2001;32:1249-1272.
Mansfield PF, Hohn DC, Fornage BD, Gregurich MA, Ota DM. Complications and failures of subclavian-vein catheterization. N Engl J Med 1994;331:1735-1738.
Sznajder JI, Zveibil FR, Bitterman H, Weiner P, Bursztein S. Central vein catheterization: Failure and complication rates by three percutaneous approaches. Arch Intern Med 1986;146:259-261.
Schummer W, Sakka SG, Hütmann E, Reinhart K, Schummer C. Ultrasound guidance for placement control of central venous catheterization. Survey of 802 anesthesia departments for 2007 in Germany. Anaesthesist 2009;58:677-685.
O´Grady NP, Alexander M, Dellinger EP, Gerberding JL, Heard SO, Maki DG, et al. Guidelines for the prevention of intravascular catheterrelated infections. Infect Control Hosp Epidemiol 2002;23:759-769.
Ullman JI, Stoelting RK. Internal jugular vein location with the ultrasound Doppler blood flow detector. Anesth Analg 1978;57:118.
Nickalls RW. A new percutaneous infraclavicular approach to the axillary vein. Anaesthesia 1987;42:151-154.
Taylor BL, Yellowlees I. Central venous cannulation using the infraclavicular axillary vein. Anesthesiology 1990;72:55-58.
Yeow KM, Kaufman JA, Rieumont MJ, Geller SC, Waltman AC. Axillary vein puncture over the second rib. AJR Am J Roentgenol 1998;170:924-926.
Martin C, Auffray JP, Saux P, Albanese J, Gouin F. The axillary vein: an alternative approach for percutaneous pulmonary artery catheterization. Chest 1986;90:694-697.
Sandhu NS, Capan LM. Ultrasound-guided infraclavicular brachial plexus block. Br J Anaesth 2002;89:254-259.
National Institute for Clinical Excellence. Guidance on the use of ultrasound locating devices for placing central venous catheters (Technology Appraisal Guidance-No. 49) London: NICE, 2002 Sept [Updated 2005 Aug; accessed 2009, Nov 09]. Available at http:www.nice.org.uk/nicemedia/pdf/Ultrasound_49_GUIDANCE.pdf
Hind D, Calvert N, McWilliams R, Davidson A, Paisley S, Beverley C, et al. Ultrasonic locating devices for central venous cannulation: metaanalysis. BMJ 2003;327:361-368.
Eerola R, Kaukinen L, Kaukinen S. Analysis of 13 800 subclavian vein catheterizations. Acta Anaesthesiol Scand 1985;29:193-197.
Vezzani A, Brusasco C, Palermo S, Launo C, Mergoni M, Corradi F. Ultrasound localization of central vein catheter and detection of postprocedural pneumothorax: An alternative to chest radiography. Crit Care Med 2010;38:533-538.
Atkinson P, Boyle A, Robinson S, Campbell-Hewson G. Should ultrasound guidance be used for central venous catheterisation in the emergency department? Emerg Med J 2005;22:158-164.