2009, Number 1
<< Back
Rev Mex Ing Biomed 2009; 30 (1)
Status of elbow myoelectric prosthesis: CINVESTAV-IPN prosthesis
Ramírez-García A, Toledo C. Leija L, Muñoz R
Language: English
References: 14
Page: 66-73
PDF size: 168.69 Kb.
ABSTRACT
Advances of the prostheses had allowed people who lost an extremity to win back their normal life and live it with fewer limitations. Traditional commercial elbow prosthesis has at least two degrees of freedom: flexion-extension and humeral rotation; but the human arm has 22 degrees of freedom. Thus, it is important to realize that the prosthetics have a long way to go. Furthermore, the higher the amputation level, the greater the demands on the fitting technique. This work describes some elbow myoelectric prostheses of different characteristics, which have advantages and drawbacks. Also a current status of CINVESTAV-IPN prosthesis is described. The prosthesis is formed with a parallel mechanism of actuators. That allows an increase in the number of active degrees of freedom and therefore the range of motion. This enhancement let it carry out natural movements, which is a challenge in the evolution of prosthetics devices. Finally, a comparison of CINVESTAV-IPN prosthesis with others is discussed.
REFERENCES
http://www.aapmr.org/zdocs/assembly/handouts/M116.pdf, November 2008.
Marquardt E. The Heidelberg pneumatic arm prosthesis. J of Bone and Joint Surgery 1965; 43B(3): 425-434.
Ramírez A, Muñoz R, Leija L, Vera A. Sistema de entrenamiento muscular con retroalimentación visual. Bilingual Pan American Health Care Engineering (PAHCE) Conference and Clinical/Hospital Engineering Workshop. Jan 30 to Feb 3, 2006, Long Beach, Cal. USA. ISBN: 970-94677-0-0 pp.36-39.2006.
Ramírez-García A, Gutiérrez-Salgado JM, Muñoz-Guerrero R, Leija-Salas L. Classification of EMG Signal by Means of WNN for Myoelectric Control. Bilingual Pan American Health Care Engineering (PAHCE) Conference and Clinical/Hospital Engineering Workshop. Jan 28 to Feb 1, 2008. Long Beach, Ca, USA. ISBN: 978-1-60585-006-1. 87-90pp.
Díaz G. Propuesta de un control del movimiento de una prótesis trans-humeral de tres grados de libertad, con actuadores en paralelo. [Spanish] MSc Thesis, Sección Bioelectrónica, CINVESTAV-IPN, México, D.F., 2004.
Alvin C. Pike, CP, works for Otto Bock Orthopedic Industries in Minneapolis and is a past president of the American Academy of Orthotists and Prosthetists.
«Otto Bock Hand» www.ottobock.com, January 2009.
«The Utah Arm», www.utaharm.com, january 2009.
Instruction Manual, For prosthetists trained to fit the Utah Arm, Document No. 1910024 - Rev. B Feb 2006, © Motion Control, Inc.
«The Boston Elbow», Health Technology Case Study 29, November 1984, http://www.liberatingtech.com/products/LTI_Boston_Arm_Systems.asp, January 2009.
Congress of the USA: Office of Technology Assessment. Health Technology Case Study 29: The Boston Elbow. Washington, D. C. 1984.
Escudero AZ. Desarrollo de una prótesis con 4 grados de libertad activos para reemplazo por arriba del codo. [Spanish] PhD Thesis. CINVESTAV-IPN, Departamento de Ingeniería Eléctrica, Sección Bioelectrónica, México, D.F. Septiembre 2002.
Escudero AZ, Alvarez J, Leija L. Development and characterization of electromechanical muscles for driving trans-humeral myoelectric prostheses. Prosthetics and Orthotics International 2002; 26: 226-234.
Escudero AZ, Alvarez J, Leija L. Development of a parallel myoelectric prosthesis for above elbow replacement. 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society (EMBS/BMES) Conference. 23-26 Oct. 2002; 3: 2404-2405.