ABSTRACT
Objective: To determine the frequency of expulsion of the intrauterine device TCu380A (IUD) inserted either immediately postpartum or after a delayed period. We aimed to identify the factors associated with expulsion.
Materials and Methods: A longitudinal and com-parative study was carried out in three Family Medicine Units of the
Instituto Mexicano del Seguro Social (IMSS) of Leon, Guanajuato. One hundred twenty-five women who had a vaginal delivery and who elected to have IUD inserted immediately after delivery participated in the study along with 125 women who elected to have the IUD inserted after a delayed period after delivery. Studied factors were parity, technique, and insertion by the doctors assigned to the service and medical personnel in training (pre or postdegree). A medical review was performed one month and three months after insertion of the IUD. Results were analyzed by chi-square and Student
t test.
Results: The expulsion rates of IUDs during immediate puerperium and also after a delayed period were 16 and 2.7%, respectively (
p ‹ 0.0004). There was no statistically significant association between expulsion of the IUD and the following factors that were taken into account: age, primipara, personnel who inserted the device, and the application technique. In immediate puerperium, 25.9% of women who had multiple deliveries expelled the IUD, and in those who delayed IUD insertion, it was 4% (
p = 0.03)
Conclusions: There is a greater risk of expulsion if the IUD is inserted immediately after delivery and it is associated with multiparity. The percen-tage of expulsion in immediate puerperium is similar to that reported in the literature.
REFERENCES
1. Lemarroy MI, Salas M. Causas de rechazo del dispositivo intrauterino. Ginecol Obstet Mex 1996; 64:43-44
2. Alvarado DA. Anticoncepción en México. Ginecol Obstet Mex 2002:70(5);227-235.
3. Palma Y, Rivera G. La planificación familiar en México. En: Langer A, Tolbert K, editores. Mujer: sexualidad y salud reproductiva en México. México: Edamex/Population Council; 1996. p. 153-177.
4. Tatum HJ, Saavedra BR, Ramos R, Van Kets H, Sivin I, Schmidt FH. Immediate postplacental insertion of Gyne-T 380 and Gyne-T 380 postpartum intra-uterine contraceptive devices: randomized study. Am J Obstet Gynecol 1996;175(5):1231-1234.
5. Morán MC, Fuentes G, Amado F, Higaredo H, Bailón R, Zárate A. La práctica de anticoncepción posparto en hospitales del Distrito Federal. Salud Publica Mex 1992;34(1):18-24.
6. De Cherney AH, Pernoll ML. Diagnóstico y tratamiento gineco-obstétricos. Séptima edición. México: El Manual Moderno; 1997. p. 241, 289.
7. Rowe PJ, Boccard S, Farley TMM, Peregoudov S. Long-term reversible contraception. Twelve years of experience with the TCu380A and TCu220C. Contraception 1997;56:341-352
8. Hernández VM, Becerril FL. Uso del DIU Tcu 380 modificado con filamentos de cromo en el postparto inmediato. Ginecol Obstet Mex 2000;68(2):70-76.
9. Ruiz P, Gómez-Sánchez JF, Pío I. Experiencia clínica con la aplicación del dispositivo intrauterino Tcu380A en el periodo postparto. Rev Colomb Obstet Ginecol. Disponible en: http://scielo-co.bvs.br/scielo.php? Script=sci_arttex&pid= S0034-74341998000100004 &Ing=es&nrm=iso. ISSN 0034-7434.
Mishell DR. Copper intrauterine contraceptive device event rates following insertion 4 to 8 weeks postpartum. Am J Obstet Gynecol 1982;143(1):29-35.
Lwanga SK, Lemeshow S. Determinación del tamaño de las muestras en los estudios sanitarios. Ginebra: Organización Mundial de la Salud; 1991. p. 25.
Secretaría de Salud. Norma oficial mexicana, NOM 005-SSA2-1993, de los servicios de planificación familiar.
Scott JR, DiSaia JP, Hammond BC, Spellacy NW. Tratado de obstetricia y ginecología de Danforth. Sexta edición. México: Nueva Editorial Inter-americana; 1999. p. 195.
Hernández-Leyva B, Trejo-y Pérez JA, Ducoig-Díaz L, Vázquez-Estrada P, Tomé-Sandoval P. Guía clínica para la atención prenatal. Rev Med IMSS 2003;41 (Supl):S59-S69.
Xu JX, Rivera R, Dunson TR, Zhuang lQ, Yang XL, Ma GT, Chi IC. A comparative study of two techniques used in immediate posplacenta insertion (IPPI) of the Cooper T-380A IUD in Shangai, people’s Republic of China. Cantraception 1996;54:33-38.
Grimes D, Shulz K, Van Vliet H, Stanwood N. Immediate post-partum insertion of intrauterine device: a Cochrane review. Human Reproduction 2002;17:549-554.
Cole LP, Edelman DA, Potts DM, Wheeler RG, Laufe LE. Postpartum insertion of modified intrauterine devices. J Repord Med 1984;29:677-682.