2002, Number S1
<< Back Next >>
Arch Cardiol Mex 2002; 72 (S1)
Three-chamber pacemakers (Ventricular resynchronization therapy)
Peña DMA
Language: Spanish
References: 9
Page: 163-166
PDF size: 51.63 Kb.
ABSTRACT
The medical treatment of patients with Congestive Heart Failure, functional class III-IV, has improved the quality of life, but have not reduced mortality. One group of these patients courses with intraventricular conduction delay and interventricular asynchrony, which worsens ventricular function. Resynchronization therapy is a novel alternative for the management of these individuals.
REFERENCES
Kelly TM, Cremo R, Nielsen C, Shabetai R: Prediction of outcome in late-stage Cardiomyopathy. Am Heart J 1990; 119: 1111-1121.
Xiao HB, Brecker SJ, Gibson D: Effects of abnormal activation on the time course of left ventricular pressure pulse in dilated cardiomyopathy. Br Heart J 1992, 68: 403-407.
Kass D, Chen CH, Curry C, Talbot M, Berger R: Improved left ventricular mechanics from acute VDD pacing in patients with dilated Cardiomyopathy and ventricular conduction delay. Circulation 1999; 99: 1567-1573.
Leclercq C, Cazeau S, LeBreton H, Ritter P, Mabo P, Gras D, et al: Acute hemodynamic effects of biventricular DDD pacing in patients with end-stage heart failure. J Am Coll Cardiol 1998; 32: 1825-1831.
Stellbrink C, Auricchio A, Butter C, Sack S, Vogt J, Böker D, et al: Pacing therapies in Congestive Heart Failure II Study. Am J Cardiol 2000; 86 (suppl): 138K-143K.
Abraham WT: On behalf of the multicenter in Sync randomized clinical evaluation (MIRACLE) investigators and coordinators, resynchronization rationale and design of a randomized clinical trial to assess the safety and efficacy of cardiac therapy in patients with advanced heart failure: The Multicenter InSync randomized clinical evaluation (MIRACLE). J Card Fail 2000, 6: 369-380.
Cazeau S, Leclercq C, Lavergne T, Walker S, Varma C, Linde C, et al: For the Multisite Stimulation in Cardiomyopathies (MUSTIC) Study Investigators. Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. N Engl J Med 2001; 344: 873-880.
Bristow MR, Feldman AM, Saxon LA: For the COMPANION steering committee and COMPANION clinical investigators. Heart failure management using implantable devices for ventricular resynchronization: Comparison of medical therapy, pacing and defibrillation in chronic heart failure (COMPANION) trial. J Card Fail 2000; 6: 276-285.
Daubert JC, Ritter P, LeBreton H, Gras D, Leclercq C, Lazarus A, et al: Permanent left ventricular pacing with transvenous leads inserted into the coronary veins. Pacing Clin Electrophysiol 1998; 21: 239-245.