2002, Number 2
<< Back
Bioquimia 2002; 27 (2)
Ecuations to eliminate interference of hemolised, icteric and hiperglycemic sera in rutine determinations of chemical chemistry
Sánchez-Rodríguez MA, Colunga-Reyes R, Cedillo-Martínez MP
Language: Spanish
References: 29
Page: 46-52
PDF size: 179.92 Kb.
ABSTRACT
Background: Specimens hyperglycemic, icteric or with hemolysis can produce interference at time of analysis, because the methods used in clinical chemistry determinations are based on spectrophotometric techniques.
Objective: To quantify the interference in vitro produced by different concentrations of glucose, bilirubin and hemoglobinin the usual techniques to analyze the serum levels of urea, creatinine, uric acid and cholesterol by manual and analyzer system procedures.
Methods: We collected 300 mL of free hemolysis, bilirubin,and lipemia serum. We measured glucose, urea, creatinine, uricacid, cholesterol, hemoglobin and total bilirubin serum concentration by both procedures. We add IFCC recommendedconcentrations of hemoglobin, bilirubin, and glucose, and wegot the interference point for each component using correlationgraphics and lineal equations to correct.
Results: Bilirubin serum concentration when reaches 3.0 mg/dL (51.3µmol/L) produces interference, except for cholesterol measurement. Hemoglobin serum concentration when reaches 1.0 g/L (0.062 mmol/L) produces interference in uric acid, creatinine, and cholesterol measurements. Serum glucose does not produce any interference. The regression model for uric acidand bilirubin is not significant.
Conclusions: The hemolysed and icteric specimens cause interference in most of the measurements, mainly from manual procedures. The equations obtained could be used to calculatethe analytes without interference.
REFERENCES
Kroll HM, Ellin JR. Interference with clinical laboratory analyses. ClinChem 1994; 40: 1996-2005.
Carraro P, Servidio G, Plebani M. Hemolyzed specimens: a reason forrejection or a clinical challenge? [Letter] Clin Chem 2000; 46: 306-307.
Morán-Villatoro L. Calidad en el laboratorio clínico. En: Morán-VillatoroL. Obtención de muestras sanguíneas de calidad analítica. Mejoríacontinua de la etapa preanalítica. México: Médica Panamericana; 2001.p. 28-32.
Kaplan L, Pesce A. Interferencias en el análisis espectral. En Kaplan L,Pesce A. Química clínica, técnicas de laboratorio, fisiopatología,métodos de análisis, teoría, análisis y correlación. Buenos Aires:Médica Panamericana; 1988. p. 1163-1176.
Weber AJ, Zanten PA. Interferences in current methods for measurementsof creatinine. Clin Chem 1991; 37: 695-700.
Pickard AN. Recolección y manipuleo de las muestras del paciente. En:Kaplan L, Pesce A. Química clínica, técnicas de laboratorio,fisiopatología, métodos de análisis, teoría, análisis y correlación.Buenos Aires: Médica Panamericana; 1988. p. 50-55.
Yüsel D, Dalva K. Effect of in vitro hemolysis on 25 common biochemicaltests. Clin Chem 1992; 38: 575-577.
Glick RM, Ryder WK. Double trouble: hemolysis and stabilizedhemoglobins (so you think, you seeing red now?). Clin Chem 1993;39: 1761-1763.
9.IFCC. Drug effects in clinical chemistry. Part 2. Guidelines forevaluation of analytical interferences. J Clin Chem Clin Biochem1984; 22: 275-279.
Sauders BC, Trapp RG. Bioestadística médica. México: El Manual Moderno;1993. p. 62-64, 187-214.
Tietz N. Clinical Guide to Laboratory Tests. 2nd. Ed. New York: WBSaunders. 1990. p. 174.
Murray RL. Creatinine. En: Pesce- Kaplan Publisher. Laboratory Medicine:A Scientific and Managerial Infobase. V. 4.2. 2000.
Mora-Villalpando CJ. Influencia de la bilirrubina, la hemoglobina y laglucosa en la determinación de creatinina por el método de Jaffémanual y automatizado. Tesis para obtener el título de QuímicoFarmacéutico Biólogo. FES Zaragoza, UNAM. 1998.
Carl HS, Landt M, Steelman M y cols. The Kodak Ektachem 400 analyser:evaluated for automated enzymatic determination of plasma creatinine.Clin Chem 1983; 29: 1422-1425.
Knapp ML, Mayne PD. Development of an automated kinetic Jaffémethod designed to minimize bilirrubin interference in plasmacreatinine assays. Clin Chim Acta 1987; 68: 239-246.
Jones BA, Calam RR, Howanitz PJ. Chemistry specimen acceptability. ACollege of American Pathologists Q-Probes study of 453 laboratories.Arch Pathol Lab Med 1997; 121: 19-26.
Giorgio DJ. Sustancias nitrogenadas no proteicas. En: Henry JH,Cannon CD, Winkelman WJ. Química clínica. Principios y técnicas.Madrid: JIMS; 1980. p. 513-515, 531-537.
Guy MJ, Legg FE. Bilirubin interference in determinations of creatininewith the Hitachi 737 analyzer. Clin Chem 1990; 36: 1851-1852.
Sant VP, Kreutzer HJ. Artificial icteric plasmas: unreliable indicatorsfor interference with creatinine assay on Beckman CX3. Clin Chem1995; 41: 1773-1774.
Bowers DL, Wong TE. Kinetic serum creatinine assays. II. A criticalevaluation and review. Clin Chem 1980; 26: 555-561.
Osselaer CJ, Lievens MM. More on interference of bilirubin in creatininedetermination by Hitachi analyzers. Clin Chem 1991; 37: 1460-1461.
Ihara H, Nakamura H, Yoshida M, Wu TW. Effect of bilirubin covalentlyattached to albumin on measurement of serum creatinine. Clin Chem1992; 38: 321-322.
Fossati P, Prencipe L, Berti G. Use of 3,5-dichloro-2-hydroxybenzenesulfonic acid/4-aminophenazone chromogenic systemin direct enzymatic assay of uric acid in serum and urine. Clin Chem1980; 26: 227-231.
Schultz AL. Uric acid. En: Pesce- Kaplan Publisher. Laboratory Medicine:A Scientific and Managerial Infobase. V. 4.2. 2000.
Beyne P, Lettéron P, Hervé C, Roullet JB, Delacoux E. Bilirubin interferencewith determination of creatinine, lactate, phosphorus, and uric acidon Beckman Synchron CX7. [Letter] Clin Chem 1996; 42: 988-989.
Aoki Y, Ihara H, Nakamura H, Aoki T, Yoshida M. Effects of serumbilirubin on determination of uric acid by uricase-peroxidase coupledreaction. Clin Chem 1992; 38: 1350-1352.
Pesce A, Bodowria H. Interference with enzymatic measurement ofcholesterol in serum by use of five reagent kits. Clin Chem 1977; 23:757-760.
Lindbäck B, Bergman A. A new commercial method for the enzymaticdetermination of creatinine in serum and urine evaluated: comparisonwith a kinetic Jaffé method and isotope dilution-mass spectrometry.Clin Chem 1989; 35: 835-837.
Ryder KW, Glick MR. Erroneous laboratory results from hemolyzed,icteric, and lipemic specimens. [Letter] Clin Chem 1993; 39: 1