2020, Number 1
<< Back Next >>
Rev Cub Oftal 2020; 33 (1)
Removal of a penetrating corneal and intracameral foreign body
Mokey CMO, Yang T, Ponce TY, Espinosa GA, Valdés CG, Álvarez RMB
Language: Spanish
References: 10
Page: 1-
PDF size: 423.78 Kb.
ABSTRACT
56-year-old male patient attends consultation with left eye vision reduction, pain and
redness. The patient has a history of essential hypertension and eye trauma caused by a wood
splinter while chopping wood 37 years ago. The foreign body went in as far as the anterior
chamber and remained intracorneal, since at that time it could not be totally removed. A description is provided of the surgical technique used. Scant information was found about
surgical procedures to remove similar foreign bodies. Therefore, the technique herein described
should be useful to treat analogous cases.
REFERENCES
Loporchio D, Mukkamala L, Gorukanti K. Zarbin M, Langer P, Neelakshi B. Intraocular foreign bodies: A review. Surv Ophthalmol. 2016;61(5):582-59.
Elham R, Al-Tamimi. A peculiar case of Fireworks as an intraocular foreign body in the anterior chamber. Saudi J Ophthalmol. 2014;28:225-7.
Nader Beshayab L, Kemaya H, DunnabTengku A, Kamalde AK, Hoskinde S, Watsona F. The epidemiology of open globe injuries presenting to a tertiary referral eye hospital in Australia. Injury. 2017;48(7):1348-54.
Benito-Pascuala C, Narváez-Palazona M, Jódar-Márquez F. Sáenz-Francésa E. Cuerpos extraños intraoculares tras cirugía de catarata. Archivos de la Sociedad Española de Oftalmología 2018;93(12):598-605.
Steck RP, Grant A, Timothy AS, Gary L, Legault JC. Online case reports diffuse lamellar keratitis 14 years after laser in situ keratomileusis induced by an eyelash in the flap interface 2018;6,(4):69-70.
Argyrios Ch, Jong MO, Gabriele FR, Schutz JS. Occult globe rupture: diagnostic and treatment challenge. Surv Ophthalmol. 2018;63(I5):694-9.
Ang M, Baskaran M, Werkkmeister R, Chua J , Schmellerar L. Anterior Segment Optical Tomograph. Progr Ret Eye Res. 2018;66:132-56.
Bhatendu S. New classification of ocular foreign bodies. Chin J Traumatol. 2016;19(6):319- 21.
Serdarevic R. The ocular trauma score is a method for the pronostic assesment of visual acuity in patients with close injuries. Acta Inform Med. 2015;23(2):81-5.
Grant AJ. Intraocular foreign body trauma in operation iraqi freedom and operation enduring freedom: 2001 to 2011. Ophthalmology. 2018;125(11):1675-82.