Pulmonary regurgitation is a complication of surgical correction of Tetralogy of Fallot. Right ventricle disfunction and dilation increase morbidity and mortality. The aim is to show the experience in two patients with the use of a new selfexpanding stented valve without use of cardiopulmonary bypass at Cardiocentro Pediátrico "William Soler".
REFERENCES
Gatzoulis MA, Balaji S. Wilber SA, Siu SC, Hokanson JS, Poili C, et al. Risk factors for arrhythmia and sudden death late after repair of tetralogy of Fallot: a multicenter study. Lancet. 2000 Sept 16: 356 (9234): 975-81
Oosterhof T; Straten A; Vliegen H; Meijboom F; van Dijk P; Spijkerboer A. Preoperative Thresholds for Pulmonary Valve Replacement in Patients with Corrected Tetralogy of Fallot Using Cardiovascular Magnetic Resonance; Circulation. 2007; 116: 545-551 Pediatric Cardiology
Knauth AL, Gauvreau K, Powell AJ, Landzberg MJ, Walsh EP, Lock J, del Nido P and Geva T. Ventricular size and function assessed by cardiac MRI predict major adverse clin-ical outcomes late after Tetralogy of Fallot repair Heart, Feb-ruary 1, 2008; 94(2): 211 - 216.
Schreiber C; Horer J; Vogt M; Frabz S. A new treatment op-tion for pulmonary valvar insufficiency: first experiences with implantation of a self-expanding stented valve without use of cardiopulmonary bypass. European Journal of Cardio-thoracic Surgery , 2007;31: 26—30
Park C; Lee C; Lee Y; Kim G, Kim J and Kim Y. Pulmonary valve repair late after right ventricular outflow tract recon-struction in children and adolescents. Interact Cardio-VascThoracSurg, June 1, 2010; 10(6): 906 – 909
Bonhoeffer P, BoudjemlineY, Saliba Z et al. Percutaneous replacement of pulmonary valve in a right-ventricle to pul-monary-artery prosthetic conduit with valve dysfunction. Lancet. 2000; 356: 1403-5
Khambadkone S, Coats L, Taylor A, Boudjemline Y, Derrick G, Tsang V, Cooper J, Muthurangu V, Hegde SR, Razavi RS, Pellerin D, Deanfield J, Bonhoeffer P. Percutaneous pulmo-nary valve implantation in humans: results in 59 consecutive patients. Circulation 2005;112:1189—97
Boudjemline Y, Schievano S, Bonnet C, Coats L, Agnoletti G, Khambadkone S, Bonnet D, Deanfield J, Sidi D, Bonhoef-fer P. Off-pump replacement of the pulmonary valve in large right ventricular outflow tracts: a hybrid approach. J Thorac Cardiovasc Surg 2005;129:831—7
Berdat PA, Carrel T. Off-pump pulmonary valve replacement with the new Shelhigh Injectable Stented Pulmonic Valve. J Thoraccardiovasc Surg. 2006; 131:1192-3
Berdat P, Carrel T, Switherland B. Off-pump pulmonary valve replacement with new Shelhigh Injectable Stented Pulmonic Valve. JThoracCardiovasc Surg. May, 2006 1192-1193
Qiang C; Turner M; Caputo M ; Stoica S; Marianeschi S and Parry A. Pulmonary valve implantation using self-expanding tissue valve without cardiopulmonary bypass reduces opera-tion time and blood product use. J Thorac Cardiovasc Surg. 2013 ;145(4):1040-5
Marianeschi SM, Santoro F, Ribera E, Cantena E, Vignati G, Ghiselli S, et al. Pulmonary valve implantation with the new Shelhigh Injectable Stented pulmonic valve. Ann Thorac Surg. 2008; 86: 1466-71