2015, Number 2
<< Back Next >>
Rev Odont Mex 2015; 19 (2)
Curing depth of pit and fissure sealants with use of light emitting diode (LED) at different distances
Villarreal RA, Guerrero IJ, Yamamoto NA, Barceló SFH
Language: Spanish
References: 27
Page: 76-80
PDF size: 583.89 Kb.
ABSTRACT
In the process of caries prevention, placement of pit and fissure sealants is a low-priced, effective and safe procedure. Presently, clinical operators prefer LED lamps. In pediatric dentistry, certain complications might arise such as lack of patient cooperation and small oral opening. This could result in increase of distance between light source and sealant.
Objective: The purpose of the present study was to determine whether increase of distance between light source and pit and fissure sealant affected curing depth.
Material and methods: 90 samples of pit and fissure sealant Helioseal F
® were light-cured for 20 seconds with a Bluephase C5 LED lamp (Ivoclar Vivadent
®), 30 seconds with the light source at a distance of 0 mm, 30 seconds at 5 mm and 30 seconds at 10 mm. Non-polymerized material was removed with a spatula for resin (Suter Dental
®). The sample was measured in mm with an electronic Vernier caliper; obtained value was divided into two (ADA’s Norm 27). Results were assessed with ANOVA and Tukey tests.
Results: The group treated at 0 mm exhibited curing depth of 2.01 mm (SD 0.11). The group treated at 10 mm, with 1.62 mm (SD 0.08) showed the least amount of curing depth. Statistically significant differences were found in average values when comparing the three groups (p ‹ 0.05).
Conclusion: Distancing light source from sealants affects their curing depth.
REFERENCES
Pinkham J. Odontología pediátrica. 2a edición. México, D.F.: Ed. McGraw-Hill Interamericana; 1998: pp. 529-537.
Simoensen R. Pit and fi ssure sealant: review of the literature. Pediatr Dent. 2002; 24: 393-414.
Irinoda Y, Matsumura Y, Kito H, Nakano T, Toyama T, Nakagaki H et al. Effect of sealant viscosity on the penetration of resin into etched human enamel. Oper Dent. 2000; 25: 274-282.
Barberia E. Odontopediatría. 2a edición. Barcelona, España: Ed. Masson; 2001: pp. 190-191.
Deb S, Mallet R, Millar B. The effect of curing with plasma light on the shrinkage of dental restorative materials. J Oral Rehabil. 2003; 30: 723-728.
Gigo D, De Oliveira G, Carneiro C, Pereira J, De Lima M. Microhardness of resin-based materials polymerized with LED and halogen curing units. Braz Dent J. 2005; 16 (2): 98-102.
Knezevic A, Tarle Z, Meniga A, Sutalo J, Pichler G. Infl uence of light intensity from different curing units upon composite temperature rise. J Oral Rehabil. 2005; 32: 362-367.
Halvorson R, Erickson R, Davidson C. Polymerization effi ciency of curing lamps: a universal energy conversion relationship predictive of conversion of resin-based composite. Oper Dent. 2004; 29 (1): 105-111.
Yap A, Saw T, Cao T. Composite cure and pulp-cell cytotoxicity associated with LED curing lights. Oper Dent. 2004; 29 (1): 92-99.
Soh M, Yap A, Siow K. Comparative depths of cure among various curing light types and methods. Oper Dent. 2004; 29 (1): 9-15.
Yap A, Soh M. Curing effi cacy of a new generation high-power LED lamp. Oper Dent. 2005; 30 (6): 758-763.
Coelho M, Santos G, Nagem H, Mondelli R, El-Mowafy O. Effect of light curing method on volumetric polymerization shrinkage of resin composites. Oper Dent. 2004; 29 (2): 157-161.
Yap A, Soh M, Han V, Siow K. Infl uence of curing lights and modes on cross-link density of dental composites. Oper Dent. 2004; 29 (4): 410-415.
Neo B, Soh M, Teo J, Yap A. Effectiveness of composite cure associated with different light-curing regimes. Oper Dent. 2005; 30 (6): 671-675.
Tarle Z, Knezevic A, Demoli N, Meniga A, Unterbrink G, Ristic M et al. Comparison of composite curing parameters: effects of light source and curing mode on conversion, temperature rise and polymerization shrinkage. Oper Dent. 2006; 31 (2): 219-226.
Vandewalle K, Roberts H, Tiba A, Charlton D. Thermal emission and curing effi ciency of LED and halogen curing lights. Oper Dent. 2005; 30 (2): 257-264.
Mavropoulos A, Staudt C, Kiliaridis S, Krejci I. Light curing time reduction: in vitro evaluation of new intensive light-emitting diode curing units. Eur J Orthod. 2005; 27: 408-412.
Nomoto R, McCabe J, Hirano S. Comparison of halogen, plasma and LED curing units. Oper Dent. 2004; 29 (3): 287-294.
Soh M, Yap A, Yu T, Shen Z. Analysis of the degree of conversion of LED and halogen lights using micro-raman spectroscopy. Oper Dent. 2004; 29 (5): 571-577.
Bala O, Üctasli M, Tüz M. Barcoll hardness of different resin-based composites cured by halogen of light emitting diode (LED). Oper Dent. 2005; 30 (1): 69-74.
Santos G, Medeiros I, Fellows C, Muench A, Braga R. Composite depth of cure obtained with QTH and LED units assessed by microhardness and micro-raman spectroscopy. Oper Dent. 2007; 31 (1): 79-83.
Barnes D, Kihn P, Fraunhofer J, Elsabach A. Flow characteristics and sealing ability of fi ssure sealants. Oper Dent. 2000; 25: 306-310.
Hatibovik S, Braverman I. Microleakage of sealants after conventional, bur, and air-abrasion preparation of pits and fi ssures. Pediatr Dent. 1998; 20 (3): 173-176.
Millar B, Nicholson J. Effect of curing with anplasma light on the properties of polymerizable dental restorative materials. J Oral Rehabil. 2001; 28: 549-552.
Shortall A. How light source and product shade infl uence cure depth for a contemporary composite. J Oral Rehabil. 2005; 32: 906-911.
Silta T, Dunn W, Peters C. Effect of shorter polymerization times when using the latest generation of light-emitting diodes. Am J Orthod Dentofacial Orthop. 2005; 128: 744-748.
Staudt C, Marvopoulos A, Boullaguet S, Kiliaridis S, Krejci I. Light-curing time reduction with a new high-power halogen lamp. Am J Orthod Dentofacial Orthop. 2005; 128: 749-754