ABSTRACT
Introduction: This multi-center study (Cabueñes Hospital and Santa Lucía University Hospital) assessed the results of a retrospective and ongoing series of 135 total hip arthroplasties (THA) in which a latest generation dual-mobility cup was implanted.
Material and methods: A total of 135 THAs performed between 2005 and 2008 were analyzed. Mean follow-up was 32 months. The causes of surgery were: coxarthrosis in 31.8% and hip fracture in 68.1%. Mean age was 82.1 years. All patients were seen at regular follow-up visits for clinical and radiological assessments.
Results: The follow-up lasted over 24 months in 121 THAs (14 patients died). In the most recent follow-up, in May 2011, 119 cups did not show any loosening. Complications were as follows: 2 postoperative dislocations; 4 DVTs; 3 infections; 5 periprosthetic fractures; 2 loosened cups, and one subsided stem. The mean preoperative Harris Hip Score (HHS) was 45, 83; the mean postoperative HHS was 80, 03. Only two of the 135 cups analyzed had radiographic modifications without clinical signs. Isolated cup survival at 12 months was 97.03% (87.3-99.2) with a 95% confidence interval; survival at 5 years was 96.7% (85.4-98.8).
Discussion: In our study, the new dual-mobility cup showed good results for the following indications: primary coxarthrosis and femur neck fractures.
Conclusion: The complication rate in our series was similar to the one reported in other series in the literature, except for dislocation. The latter was considerably less frequent (1.48%) in our series compared to the rates reported by the classical series, especially in patients with neuromuscular or cognitive problems (one third of patients).
REFERENCES
Charnley J: The low friction arthroplasty of the hip. Theory and practice. Berlin, Heidelberg: Springer Verlag; 1979.
Picault C, Michel CR, Vidil R: Prothèses totales de hanche de Charnley: 4,300 cas opérés de 1968 à 1979. Rev Chir Orthop. 1980; 66(2) : 57-67.
Hendlundh U, Ahnfelt L, Fredin H: Incidence of dislocation after total hip arthroplasty. Comparison of different registration methods in 408 cases. Acta Orthop Scand. 1992; 63: 403-6.
Callaghan JJ, Heitoff BE, Goetz DD, Sulivan PM, Pedersen DR, Johnston RC: Prevention of dislocation after hip arthroplasty: lessons from long-term follow-up. Clin Orthop. 2001; 393: 157-62.
Von Knock M, Berry DJ, Harmsen WS, Morrey BF: Late dislocation after total hip arthroplasty. J Bone Joint Surg. 2002; 84A: 1949-53.
Bozic KJ, Kurtz SM, Lau E, Ong K, Vail TP, Berry DJ: The epidemiology of revision THA in the United States. JBJS Am. 2009; 91: 128-33.
Newington DP, Bannister GC, Fordyce M: Primary total hip replacement in patients over 80 years of age. J Bone Joint Surg. 1990; 72B: 450-2.
Jolles BM, Zangger P, Leyvraz PF: Factors predisposing to dislocation after primary total hip: a multivariate analysis. J Arthroplasty. 2002; 17: 282-8.
Khan MA, Brakenbury P, Reynolds ISR: Dislocation following total hip arthroplasty. J Bone Joint Surg. 1981; 63B: 214-8.
Amstutz HC, Kody MH: Dislocation and subluxation. In: Amstutz HC. Ed hip arthroplasty. New York, Edimbourg, London, Melbourne, Tokyo: Churchil Livingston; 1991: 429-47.
Williams JF, Gottesman MJ, Mallory TH: Dislocations after total hip arthroplasty. Treatment with an above-knee hip spica cast. Clin Orthop. 1982; 171: 53-8.
Woo RY, Morrey BF: Dislocations after total hip arthroplasty. J Bone Joint Surg. 1982; 64A(9): 1295-306.
Courtois B, Variel R, Le Saout J, Kerboull B, Lefevre C: À propos de 87 luxations de prothèse totale de hanche. Int Orthop. 1985; 9(3): 189-93.
Fackler CD, Poss R: Dislocation in total hip arthroplasties. Clin Orthop. 1980; 151: 169-78.
Dorr LD, Wolf AW, Chandler R, Conaty JP: Classification and treatment of dislocation of total hip arthroplasty. Clin Orthop. 1983; 173: 151-8.
Fontes D, Benoit J, Lortat-Jacob A, Didry R: La luxation des prothèses totales de hanche. Validation statistique d‘une modélisation, à propos de 52 cas. Rev Chir Orthop. 1991; 77(3): 163-70.
Wroblewski BM: Direction and rate of socket wear in Charnley low friction arthroplasty. J Bone Joint Surg. 1985; 67B : 757-61.
Gore DR, Murray MP, Sepic SB, Gardner GM: Anterolateral compared to psoterolateral approach in total hip arthroplasty. Differences in component positioning, hip strength, and hip position. Clin Orthop. 1982; 165: 180-7.
McGrory BJ, Morrey BF, Cahalan TD, An KN, Cabanela ME: Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty. J Bone Joint Surg. 1995; 77B: 865-9.
Lecuire F, Benareau I, Rubini J, Basso M: Luxation intraprothétique dans la cupule à double mobilité de Bousquet. Rev Chir Orthop. 2004; 90: 249-55.
Farizon F, Delavison R, Azoulai JJ, Bousquet G: Results with a cementless alumina coated cup with dual mobility. Int Orthop. 1998; 22: 219-24.
Aubriot JH, lesimple P, Leclercq S: Étude du cotyle non scellé de Bousquet dans cent prothèses totales de hanche hybrids. Recul moyen de 5 ans. Acta Orthop Belg. 1993; 59(suppl. 1): 261-71.
Phlippot R, Adam P, Farizon F, Fessy MH: Survie à dix ans d‘une cupule double mobilité non cimentée. Rev Chir Orthop. 2006; 81: 389-94.
Leclerc S, El Blidi S, Aubriot JH: Traitement de la luxation récidivante de prothèse totale de hanche par le cotyle de Bousquet. Rev Chir Orthop. 1995; 81: 389-94.
Beguin L, Adam P, Farizon F, Fessy MH: Total hip arthroplasy: treatment of chronic instability using a double-mobility cup. J Bone Joint Surg Br. 2002; 84(suppl. I): 52.
Merle-d‘Aubigné R: Cotation chiffrée de la fonction de hanche. Rev Chir Orthop Reparatrice Appar Mot. 1970; 56: 481-6.
Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969; 51(4): 737-55.
EuroQol Group: EurQol a new facility for the measurement of health-related quality of life. Health Policy. 1990; 16: 199-208.
Badia X, Roset M, Montserrat S, Herdman M, Segura A: La versión española del EuroQol: descripción y aplicaciones. Med Clin (Barc). 1999; 112(Supl. 1): 79-86.
Delee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop. 1976; 121: 20-32.
Gruen TA, McNeice GM, Amstzutz HC: Modes of failure of cemented stem-type femoral components. A radiographic analysis of loosening. Clin Orthop. 1979; 141: 17-27.
Brooker AF, Bowerman JW, Robinson RA, Rileyl H: Ectopic ossification following total hip replacement: incidence and a method of classification. J Bone Joint Surg Am. 1973; 55: 1629.
Azearate JR, De Pablos J, Cornejo F, Canadell J: Post-operative dislocation: a risk factor for periprosthetic ectopic ossifications after total hip replacement. Acta Orthop Belg. 1986; 52: 145-50.
Lettin AWF, Ware HS, Morris RW: Survivorship analysis and confidence intervals. J Bone Joint Surg Br. 1991; 73-B: 729-31.
Valdez S, Bouxin B: Cotilos con doble movilidad: principios, ventajas y resultados. Rev Asoc Argent Ortop Traumatol. 2008; 74: 102-10.
Adam P, Farizon F, Fessy MH: Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants. Revue Chir Orthop Reparatrice Appar Mot. 2005; 91(7): 627-36.
Wrobleski BM, Siney PD: Charnley low friction arthroplasty of the hip. Clin Orthop. 1993; 291: 191-201.
Fessy MH, Adam P, Farizon F, Beguin: Surface analysis of 50 explanted constrained doublemobility polyethylene cups. J Bone Joint Surg (Br). 2001; 83B: 59.
Shrader WM, Parvizi J, Lewallen DG: The use of a constrained acetabular component to treat instability after total hip arthroplasty. J Bone Joint Surg Am. 2003; 85A: 2179-83.
Forest B, Camillieri JP, Fessy MH, Adam P, Farizon F, Philippot R: Arthroplasties totales de hanche à double mobilité: étude expérimentale des contraintes à l’interface os-cupule. Rev Chir Orthop Reparatrice Appar Mot. 2007; 93(7): 50-1.
Adam P, Philippot R, Dargai F, Coumert S, Farizon F, Fessy MH: Double mobilité et luxation intra prothétique. Rev Chir Orthop. 2005; 91(6): 185-9.
Noyer D: La troisieme articulation des PTH a double mobilite. A propos de 77 revisions. Lyon, Francia: Journées Lyonnaises de chirurgie de la hanche; 2003: 209-10.
Philippot R, Farizonn F, Fessy MH, Camilleri JP, Boyer B, Derhi G, et al: Etude d’une série de 438 cupules non cimentées à double mobilité. Survival of dual mobility socket with a mean 17 years follow-up. Rev Chir Orthop Reparatrice Appar Mot. 2008; 94(1): 43-8.
Asselinau A, Beithoon Z, Molina V: Prevention of dislocation of total hip arthroplasty: the dual mobility cup. Interactive Surgery. 2007; 2(3): 160-4.
Fiquet A, Noyer D: “Polarsystem” dual mobility hip prosthesis and “minimally invasive surgery” MIS. Interactive Surgery. 2006; 1(4): 51.
Woolson ST, Rahimtoola ZO: Risk factors for dislocation during the first 3 months after primary total hip replacement. J Arthroplasty. 1999; 14: 662-8.
Tarasevicius S, Jermolajevas V, Tarasevicius R, Zegunis V, Smailys A, Kalesinskas RJ: Total hip replacement for the treatment of femoral neck fractures. Long-term results. Medicina (Kaunas). 2005; 41: 465-9.
Levy RN, Levy CM, Snyder J, Digiovanni J: Outcome and long-term results following total hip replacement in elderly patients. Clin Orthop Relat Res. 1995; (316): 25-30.
Kavanagh BF, Ilstrup DM, Fitzgerald RH Jr: Revision total hip arthroplasty. J Bone Joint Surg Am. 1985; 67A: 517-26.
Parvizi J, Sullivan T, Duffy G, Cabalena M: Fifteen-tear clinical survivor ship of Harris-Galante total hip arthroplasty. J Arthroplasty. 2004; 19: 672-5.
Delaunay C, Kapandji AJ: Acetabular screw rings and surface treatments. A series of 115 consecutive primary acetabular arthroplasties with the Karl Zweymüller threaded cup with a 5.8 years average follow-up. Rev Chir Orthop. 1999; 84: 759-62.
Lautridou C, Lebel B, Burdin G, Galaud B, Hulet C, Vielpeau C: La cupule à double mobilité dans l’arthroplastie totale de hanche primitive. Résultats à 15 ans de recul minimum, à propos de 437 hanches. Rev Chir Orthop. 2007; 93: 52.
Vielpeau C, Lebel B, Ardouin L, Burdin G, Lautridou C: The dual mobility socket concept: experience with 668 cases. International Orthopaedics. 2009; 35(2): 225-30.
Yun AG, Padgett D, Pellicci P, Dorr LD: Constrained acetabular liners: mechanisms of failure. J Arthroplasty. 2005; 20: 536-41.
Philippot R, Camilleri J, Boyer B, Adam P, Farizon F: The use of a dualarticulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. International. Orthopaedics. 2009; 33: 927-93.
Murcia A, Azorín LM, Blanco A, Ferrer H, Gallart X, García-Cimbrelo E, et al: Luxación recidivante de prótesis total de cadera. Rev Ortp Traumatol. 2006; 50: 454-67.