2014, Number 1
<< Back Next >>
Rev Cub Oftal 2014; 27 (1)
Keratometric study of hypermetropic patients with laser surgery by using Pentacam vs. Maloney method
Cárdenas DT, Vinardell PS, Capote CA, Pérez CEC, Cuan AY, Cruz ID
Language: Spanish
References: 36
Page: 100-109
PDF size: 112.09 Kb.
ABSTRACT
Objective: to compare the keratometries given by the Pentacam in hyperopic patients operated on with laser and those obtained through Maloney method in "Ramón Pando Ferrer" Cuban Institute of Ophthalmology from March to May of 2013.
Methods: a prospective study was conducted in 50 eyes from 27 hyperopic patients operated on with LASIK, in which average keratometry was estimated using Maloney method and then compared with those of Pentacam system; the used variables were total central keratometric value and
Equivalent K-reading Power of color maps, as well
as the true net power (total keratometic value at 3,0 mm) and the readings of equivalent keratometry at different diameter of HolladayReport programs. The average preoperative keratometries of the medical histories and those of the Pentacam system were also compared. The statistical analysis included paired T test, using a 95 % significance level.
Results: there were not significant statistical differences among the keratometries by Maloney method, the
Equivalent K-reading power and the readings of equivalent keratometries at different diameters, being that of 4,5 mm the more accurate. The rest of the measurements differed in a significant way. There were differences among the preoperative keratometries.
Conclusion: the Pentacam system provides corneal powers that did not statistically differ from those obtained by the Maloney method in hyperopic eyes with prior LASIK.
REFERENCES
Pérez EC, Cuan Y, Cárdenas T, Méndez AM, Rodríguez B. Aplicación del método de Maloney en el cálculo del lente intraocular después de cirugía refractiva corneal. Rev Cubana Oftalmol. 2010;23(Supl. 1):470-9.
Prado SA, Camas BJ, Sosa LS, Nava HN. Cómo evitar la sorpresa refractiva (Parte II). Cálculo del poder dióptrico de lentes intraoculares en casos especiales. Rev Mex Oftalmol. 2010;84(1):39-48.
Pakoslawski F, Ghilino O, Marotta H, Estavillo M, Argibay MC. Cálculo de lente intraocular luego de cirugía refractiva miópica: nuestro método. Resultados Preliminares. Buenos Aires: Arch Oftalmol. 2009;80(3):91-4.
Urrutia Breton IP, Matiz Moreno H, Morales Gómez ME. Resultados refractivos en pacientes operados de catarata con antecedente de cirugía refractiva corneal. Rev Mex Oftalmol. 2006;80(6):312-7.
Mesa JC, Martí T, Arruga J. Cálculo de la potencia de la lente intraocular en situaciones especiales. Ann Oftalmol. 2008;16(2):68-89.
Borasio E, Stevens E, Smith GT. Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: best formula. J Cataract Refract Surg. 2006;32(12):2004-14.
Mesa JC, Ruiz C. El cálculo de la lente intraocular tras cirugía fotorrefractiva corneal. Revisión de la literatura. Arch Soc Esp Oftalmol. 2009;84(6):283-92.
DeMill D, Hsu M, Moshirfar M. Surgery intraocular lens calculator for eyes with prior radial keratotomy. Clin Ophthalmol. 2011;5:12437.
Ortega JG, Freidell H, Kwitko S, Lu LW, Zacharias W, Sáchez JC. Cuál es la técnica de elección para el cálculo del LIO poscirugía refractiva. Noticiero ALACCSAR/ diciembre 2011. [citado enero 2013]. Disponible en: http://www.alaccsa-r.com
Mohammad AJ, Sepehr F, Parviz M. Intraocular Lens power calculation after corneal refractive surgery. J Ophthalmic Vis Res. 2012;7(1) 106.
Shammas HJ, Hoffer KJ, Shammas MC. Scheimpflug photography keratometry readings for routine intraocular lens power calculation. J Cataract Refract Surg. 2009;35(2):330-4.
Mesa J, Rouras A, Cabiró I, Amías V, Porta J, Solanas L. Intraocular lens power calculation after myopic excímer laser surgery with no previous data. J Emmetropia. 2011;2(2):97-102.
Savini G, Barboni P, Zanini M. Intraocular lens power calculation after myopic refractive surgery: theoretical comparison of different methods. Ophthalmology. 2006;113(8):127-82.
Savini G, Hoffer KJ, Zanini M. IOL Power Calculations after LASIK and PRK. Cataract Refractive Surgery Today Europe [Internet]. 2007 [citado 12 de diciembre de 2012]. Disponible en: http://www.bmctoday.net/crstodayeurope/2007/04/article.asp?f=0407_09.php
Puell MC. Introducción a la cirugía refractiva. Universidad Complutense de Madrid [Internet]. 2009 [citado junio de 2013]. Disponible en: http://eprints.ucm.es/16915/1/Introducci%C3%B3n_a_la_cirug%C3%ADa_refractiva _%5BModo_de_compatibilidad%5D.pdf
Hurtado E. Cirugía refractiva láser corneal LASIK vs. PRK en miopía baja, media y elevada. España: Universidad de Alicante [Internet]. 2011 [citado 20 de Junio de 2013]. Disponible en: http://hdl.handle.net/10045/19816
Mesa JC, Martí T, Arruga J. Cálculo del poder dióptrico de la lente intraocular (LIO) tras cirugía refractiva. Arch Soc Esp Oftalmol. 2005;80(12):699-703.
Feiz V, Mannis MJ, Garcia-Ferrer F, Kandavel G. Intraocular Lens power calculation after laser in situ Keratomileusis for myopia and hyperopia. A standardized approach. Cornea. 2001;20(8):792-7.
Argento C, Cosentino M, Badoza D. Intraocular lens power calculation after refractive surgery. J Cataract Refract Surg. 2003;29(7):1346-51.
Shammas HJ, Shammas MC. No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis. J Cataract Refract Surg. 2007;33(1):31-6.
Latkany AR, Chokshi AR, Speaker MG. Intraocular lens calculations after refractive surgery. J Cataract Refract Surg. Mar 2005;31(3):562-70.
Wang L, Booth MA, Koch DD. Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK. Ophthalmology. 2004;111(10):1825-31.
Mesa JC, Amías V, Cabiró I, Cotanda P, Porta J, Solanas L. Algoritmo de corrección de la queratometría tras cirugía refractiva corneal. Ann Oftalmol. 2009;17(3):137-43.
Hill WE. IOL Calculations after refractive surgery. Cataract and refractive surgery today. 2012:1-3.
Savini G, Carbonelli M, Barboni P, Hoffer KJ. Clinical relevance of radius of curvature error in corneal power measurements after excimer laser surgery. J Cataract Refract Surg. 2010;36(1):82-6.
Kawamorita T, Uozato H, Kamiya K, Leon Bax, Tsutsui K, Aizawa D, et al. Repeatability, reproducibility and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement. J Cataract Refract Surg. 2009;35(1):127-33.
Seitz B, Langenbucher A. Intraocular lens power calculation in eyes after corneal refractive surgery. J Refract Surg. 2000;16(3):349-61.
Srivannaboon S, Rakpanichmanee T, Cheng AC, Fam HB. Estimation of posterior corneal power for IOL calculation after myopic LASIK. J Refract Surg. 2008;24(9):946-51.
Holladay JT, Hill WE, Steinmueller A. Corneal power measurements using Scheimpflug imaging in eyes with prior corneal refractive surgery. J Cataract Refract Surg. 2009;25(10):862-8.
Morcillo R, Muñoz F, Durán S. La cámara Scheimpflug rotacional Pentacam. Actualizaciones Tecnológicas en Oftalmología. Studium Oftalmológico [Internet]. 2006 [citado noviembre 2012];24(4). Disponible en: http://www.oftalmo.com/studium/studium2006/stud06-4/06d-indice
Savini G, Barboni P, Profazio V, Zanini M, Hoffer KJ. Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery. J Cataract Refract Surg. 2008;34(5):809-13.
Viteri E. Uso del Pentacam para calcular el poder del LIO. High Lights of Ophthalmology [Internet]. 2008 [citado junio 2013];36(3). Disponible en: http://www.omnisrl.com.ar/descargas/uso_del_pentacam_por_ calcular_el_poder_del_lio_viteri_spanish.pdf
Cuan Y, Pérez E, Montero E, Santiesteban I, Ortega L, Cárdenas T. Utilidad del Pentacam para medir el poder corneal después de cirugía refractiva con excímer láser. Rev Cubana Oftalmol. 2010;23(Supl. 1):513-21.
Cárdenas T, Torres R, Corcho Y, Capote A, Cuan Y, Hernández I. Sistema Scheimpflug Pentacam vs. método de la historia clínica en hipermétropes con cirugía refractiva previa. Rev Cubana Oftalmol. 2013 [citado junio 2013];26(1). Disponible en: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/173
Jain R, Dilraj G, Grewal SPS. Repeatability of corneal parameters with Pentacam after laser in situ keratomileusis. Indian J Ophthalmol. 2007;55(5):341-7.
Kim SW, Kim EK, Cho BJ, Kim SW, Song KY, Kim TI. Use of the pentacam true net corneal power for intraocular lens calculation in eyes after refractive corneal surgery. J Refract Surg. 2009;25(3):285-9.