2013, Number 2
<< Back
Acta Ortop Mex 2013; 27 (2)
Reverse shoulder arthroplasty: complications and prevention
Campo-Aguirre R, San Román-Rodríguez E, Canales-Ibarra A, Campo-Aguirre V, Delgado-Gutiérrez PA, Garzón-Muvdi J
Language: Spanish
References: 48
Page: 128-132
PDF size: 66.58 Kb.
ABSTRACT
The total shoulder prosthesis in
reverse was designed as a treatment for patients
with arthropathy deficiency rotator cuff because
the conservative treatment failed. The indications
for its use have evolved; these include arthropathy
deficient rotator cuff, reconstruction humeral
head fractures, hemiarthroplasties revision and
reconstruction after tumor resection. Successful
placement depends on the patient having a function
adequately and good quality deltoid in the glenoid
bone and in the proximal humerus. Until a
few years ago data was no clear on the success of
this procedure, currently encouraging results have
been reported, however, they have had a high cost
due to the high rate of complications, which are divided
into specific and common to the prosthesis
shoulder surgeries. The primary objective of this
review is to assess the most common complications
of the prosthesis in reverse, how to treat them and
how we can avoid them.
REFERENCES
Grammont P, Trouilloud P, Laffay JP, Deries X: Etude et realisation d’une nouvelle prothese d’epaule. Rhumatologie 1987; 39(10): 407-18.
Boileau P, Watkinson DJ, Hatzidakis AM, Balg F: Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elbow Surg 2005; 14(1): 147S-61S.
Boileau P, Watkinson D, Hatzidakis AM, Hovorka I: Neer Award 2005: The Grammont reverse shoulder prosthesis: results in cuff tear arthritis, fracture sequelae and revision arthroplasty. J Shoulder Elbow Surg 2006; 15(5): 527-40.
Boulahia A, Edwards TB, Walch G, Baratta RV: Early results of a reverse design prosthesis in the treatment of arthritis of the shoulder in elderly patients with a large rotator cuff tear. Orthopedics 2002; 25(2): 129-33.
Cuff D, Pupello D, Virani N, Levy J, Frankle M: Reverse shoulder arthroplasty for the treatment of rotator cuff defi ciency. J Bone Joint Surg Am 2008; 90(6): 1244-51.
De Wilde L, Sys G, Julien Y, Van Ovost E, Poffyn B, Trouilloud P: The reversed Delta shoulder prosthesis in reconstruction of the proximal humerus after tumour resection. Acta Orthop Belg 2003; 69(6): 495-500.
De Wilde LF, Plasschaert FS, Audenaert EA, Verdonk RC: Functional recovery after a reverse prosthesis for reconstruction of the proximal humerus in tumor surgery. Clin Orthop Relat Res 2005; 430: 156-62.
Frankle M, Siegal S, Pupello D, Saleem A, Mighell M, Vasey M: The Reverse Shoulder Prosthesis for glenohumeral arthritis associated with severe rotator cuff defi ciency. A minimum two-year follow-up study of sixty patients. J Bone Joint Surg Am 2005; 87(8): 1697-705.
Gerber C, Pennington SD, Nyffeler RW: Reverse total shoulder arthroplasty. The Journal of the American Academy of Orthopaedic Surgeons 2009; 17(5): 284-95.
Guery J, Favard L, Sirveaux F, Oudet D, Mole D, Walch G: Reverse total shoulder arthroplasty. Survivorship analysis of eighty replacements followed for fi ve to ten years. J Bone Joint Surg Am 2006; 88(8): 1742-7.
Levy J, Frankle M, Mighell M, Pupello D: The use of the reverse shoulder prosthesis for the treatment of failed hemiarthroplasty for proximal humeral fracture. J Bone Joint Surg Am 2007; 89(2): 292-300.
Matsen FA III, Boileau P, Walch G, Gerber C, Bicknell RT: The reverse total shoulder arthroplasty. J Bone Joint Surg Am 2007; 89(3): 660-7.
Rittmeister M, Kerschbaumer F: Grammont reverse total shoulder arthroplasty in patients with rheumatoid arthritis and nonreconstructible rotator cuff lesions. J Shoulder Elbow Surg 2001; 10(1): 17-22.
Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Mole D: Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders. J Bone Joint Surg Br 2004; 86(3): 388-95.
Van Seymortier P, Stoffelen D, Fortems Y, Reynders P: The reverse shoulder prosthesis (Delta III) in acute shoulder fractures: technical considerations with respect to stability. Acta Orthop Belg 2006; 72(4): 474-7.
Vanhove B, Beugnies A: Grammont’s reverse shoulder prosthesis for rotator cuff arthropathy. A retrospective study of 32 cases. Acta Orthop Belg 2004; 70(3): 219-25.
Wall B, Nove-Josserand L, O’Connor DP, Edwards TB, Walch G: Reverse total shoulder arthroplasty: a review of results according to etiology. J Bone Joint Surg Am 2007; 89(7): 1476-85.
Werner CML, Steinmann PA, Gilbart M, Gerber C: Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis. J Bone Joint Surg Am 2005; 87(7): 1476-86.
Holcomb JO, Cuff D, Petersen SA, Pupello DR, Frankle MA: Revision reverse shoulder arthroplasty for glenoid baseplate failure after primary reverse shoulder arthroplasty. Journal of shoulder and elbow surgery/American Shoulder and Elbow Surgeons [et al] 2009; 18(5): 717-23.
De Wilde LF, Van Ovost E, Uyttendaele D, Verdonk R: Results of an inverted shoulder prosthesis after resection for tumor of the proximal humerus. Revue de chirurgie orthopedique et reparatrice de l’appareil moteur 2002; 88(4): 373-8.
Wall B, Walch G, Jouve F, Mottier F: The reverse shoulder prosthesis for revision of failed total shoulder arthroplasty. In: Walch G, Boileau P, Mole D, Favard L, Levigne C, Sirveaux F (eds). Reverse Shoulder Arthroplasty Clinical Results -- Complications -- Revision. Montpellier: Sauramps Medical; 2006: 231-42.
Valenti PH, Boutens D, Nerot C: Delta 3 reversed prosthesis for osteoarthritis with massive rotator cuff tear: long-term results (>5 years). In: Walch G, Boileau P, Mole D (eds). Shoulder Prosthesis: Two to Ten Year Follow-up. Montpellier: Sauramps Medical; 2001: 253-9.
Jacobs R, Debeer P, De Smet L: Treatment of rotator cuff arthropathy with a reversed Delta shoulder prosthesis. Acta Orthop Belg 2001; 67(4): 344-7.
Nove-Josserand L, Walch G, Wall B: Instability of the reverse prosthesis. In: Walch G, Boileau P, Mole D, Favard L, Levigne C, Sirveaux F (eds). Reverse Shoulder Arthroplasty Clinical Results -- Complications -- Revision. Montpellier: Sauramps Medical; 2006: 247-60.
Gutierrez S, Keller TS, Levy JC, Lee WE III, Luo ZP: Hierarchy of stability factors in reverse shoulder arthroplasty. Clin Orthop Relat Res 2008; 466(3): 670-6.
Nove-Josserand L, Walch G, Wall B: Instability of the reverse prosthesis. In: Walch G, Boileau P, Mole D, Favard L, Levigne C, Sirveaux F (eds). Reverse Shoulder Arthroplasty Clinical Results -- Complications -- Revision. Montpellier: Sauramps Medical; 2006: 47-260.
Wierks C, Skolasky RL, Ji JH, McFarland EG: Reverse total shoulder replacement. Intraoperative and early postoperative complications. Clin Orthop Relat Res 2009; 467: 225-34.
Nyffeler RW, Werner CML, Gerber C: Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elbow Surg 2005; 14(5): 524-8.
Gutierrez S, Greiwe RM, Frankle MA, Siegal S, Lee WE III: Biomechanical comparison of component position and hardware failure in the reverse shoulder prosthesis. J Shoulder Elbow Surg 2007; 16(3 Suppl): 9S-12S.
McFarland EG, Sanguanjit P, Tasaki A, Keyurapan E, Fishman EK, Fayad LM: The reverse shoulder prosthesis: a review of imaging features and complications. Skeletal Radiol 2006; 35(7): 488-96.
Gutierrez S, Levy JC, Frankle MA, Cuff D, Keller TS, Pupello DR, Lee WE III: Evaluation of abduction range of motion and avoidance of inferior scapular impingement in a reverse shoulder model. J Shoulder Elbow Surg 2008; 17(4): 608-15.
Levigne C, Boileau P, Favard L, Garaud P, Mole D, Sirveaux F, Walch G: Scapular notching in reverse shoulder arthroplasty. J Shoulder Elbow Surg 2008; 17(6): 925-35.
Constant CR, Murley AHG: A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 1987; 214: 160-4.
Middernacht B, De Wilde L, Mole D, Favard L, Debeer P: Glenosphere disengagement: a potentially serious default in reverse shoulder surgery. Clin Orthop Relat Res 2008; 466(4): 892-8.
Simovitch RW, Zumstein MA, Lohri E, Helmy N, Gerber C: Predictors of scapular notching in patients managed with the Delta III reverse total shoulder replacement. J Bone Joint Surg Am 2007; 89(3): 588-600.
Burkhead WZ: Why I like the superior approach. In: Walch G, Boileau P, Mole D, Favard L, Levigne C, Sirveaux F (eds). Reverse Shoulder Arthroplasty Clinical Results -- Complications -- Revision. Montpellier: Sauramps Medical; 2006: 199.
Nyffeler RW, Werner CML, Gerber C: Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elbow Surg 2005; 14(5): 524-8.
Gutierrez S, Comiskey CA, IV, Luo ZP, Pupello DR, Frankle MA: Range of impingement-free abduction and adduction defi cit after reverse shoulder arthroplasty. Hierarchy of surgical and implant-designrelated factors. J Bone Joint Surg Am 2008; 90(12): 2606-15.
Gutierrez S, Greiwe RM, Frankle MA, Siegal S, Lee WE III: Biomechanical comparison of component position and hardware failure in the reverse shoulder prosthesis. J Shoulder Elbow Surg 2007; 16(3 Suppl): 9S-12S.
Krishnan SG: The deltopectoral approach for primary reverse prostheses - why I don’t like it! In: Walch G, Boileau P, Mole D, Favard L, Levigne C, Sirveaux F (eds). Reverse Shoulder Arthroplasty Clinical Results -- Complications -- Revision. Montpellier: Sauramps Medical; 2006: 207.
Burkhead WZ. Why I like the superior approach. In: Walch G, Boileau P, Mole D, Favard L, Levigne C, Sirveaux F (eds). Reverse Shoulder Arthroplasty Clinical Results -- Complications -- Revision. Montpellier: Sauramps Medical; 2006: 199.
Krishnan SG. The deltopectoral approach for primary reverse prostheses - why I don’t like it! In: Walch G, Boileau P, Mole D, Favard L, Levigne C, Sirveaux F (eds). Reverse Shoulder Arthroplasty Clinical Results -- Complications -- Revision. Montpellier: Sauramps Medical; 2006: 207.
De Wilde LF, Van Ovost E, Uyttendaele D, Verdonk R: Results of an inverted shoulder prosthesis after resection for tumor of the proximal humerus. Revue de chirurgie orthopedique et reparatrice de l’appareil moteur 2002; 88(4): 373-8.
Gutierrez S, Levy JC, Frankle MA, Cuff D, Keller TS, Pupello DR, Lee WE III: Evaluation of abduction range of motion and avoidance of inferior scapular impingement in a reverse shoulder model. J Shoulder Elbow Surg 2008; 17(4): 608-15.
Wall B, Walch G, Jouve F, Mottier F. The reverse shoulder prosthesis for revision of failed total shoulder arthroplasty. In: Walch G, Boileau P, Mole D, Favard L, Levigne C, Sirveaux F (eds). Reverse Shoulder Arthroplasty Clinical Results -- Complications -- Revision. Montpellier: Sauramps Medical; 2006: 231-42.
Gutierrez S, Comiskey CA IV, Luo ZP, Pupello DR, Frankle MA: Range of impingement-free abduction and adduction defi cit after reverse shoulder arthroplasty. Hierarchy of surgical and implant-designrelated factors. J Bone Joint Surg Am 2008; 90(12): 2606-15.
Simovitch RW, Zumstein MA, Lohri E, Helmy N, Gerber C: Predictors of scapular notching in patients managed with the Delta III reverse total shoulder replacement. J Bone Joint Surg Am 2007; 89(3): 588-600.
Cheung EV, Sperling JW, Cofi eld RH: Infection associated with hematoma formation after shoulder arthroplasty. Clin Orthop Relat Res 2008; 466(6): 1363-7.