2012, Number 3
<< Back Next >>
Rev Mex Enf Cardiol 2012; 20 (3)
Nursing interventions to the patient assisted with intraaortic counterpulsation balloon
Teniza-Noguez D, Bautista-Domínguez A, González-Flores NE, Ortiz-Alfaro AE
Language: Spanish
References: 15
Page: 117-123
PDF size: 111.84 Kb.
ABSTRACT
The nurse who provides care to the patient with intra aortic balloon pump, also known as BIAC, requires a profile according to the complexity of the care provided, i.e. must possess the knowledge, skills and abilities allowing safe and effective interventions in situations requiring immediate and timely conduct, without neglecting the human aspect in exchange for a skilled technical and ethical care; perennial challenge in the patient’s cardiovascular recovery and intensive care units. Faced with this panorama, this article details the care interventions for the patient receiving intra aortic balloon pump assistance, to guide practitioners in their daily practice.
REFERENCES
Lauga A, Perel C, D’Ortencio OA. Balón de contrapulsación intraaótico. Rev Insuf Cardiaca. 2008; (3)4: 184-195.
Sociedad Argentina de Cardiología. Consenso de asistencia circulatoria mecánica. Rev. Arg. de Cardiología. 2003; 71(6): 37-51.
Buisán F, Herrero E, Ruiz N, Páez M. Manual de cuidados críticos postquirúrgicos. Pautas de actuación clínica. Madrid: Editorial Arán; 2006.
Van de Wert F, Bax J, Betrium A, Blomstrom-Lundquvist C, Crea F, Falk V et al. Guía de práctica clínica sobre el manejo de infarto agudo de miocardio en pacientes con elevación persistente del segmento ST. Rev Esp Cardiol. 2009; 62(3): 1–47.
González CO, Maldonado RN, Mena AE, García LS, Guevara GN, Aldrete VJ. Manual de Contrapulsación Intraórtica. 2 ed. México: Manual Moderno; 2002.
Nicolás JM, Ruiz J, Jiménez X, Net A. Enfermero crítico y emergencias. España: Elsevier; 2011.
Barbeito A, Mark BJ. Monitorización de la presión arterial y la presión venosa central. Anesthesiology Clin N Am. 2006; 24: 717-735.
Dueñas CC, Mendoza FR, Álvarez GM, Ortiz RG. Perfusión tisular en el paciente crítico. Acta colombiana de cuidado intensivo. 2012; 12(2): 11-127.
Cerón DUW. Monitoreo hemodinámico avanzado en el enfermo en estado crítico. México: Editorial Prado; 2006.
Orlando Health. Fundamentals of hemodynamic monitoring. Self-learning packet [Internet]. Florida: Orlando Health, Education & Development; 2011 [access 9 January 2013]. Available: http://www.orlandohealth.com/MediaBank/Docs/SLP/FundHemMon.pdf
Boyle M, Butcher R. Hemodynamic monitoring learning package [Internet]. Agency for Clinical Innovation; 1998 [citado 9 ene 2013]. Disponible en: http://intensivecare.hsnet.nsw.gov.au/five/doc/education_packages/pow/POW_SDL_Haemodynamic.pdf
Hernández ES, González CO, García G, Arriaga GJ. Balón intraaórtico de contrapulsación (BIAC). Efectos hemodinámicos e indicaciones. Med Sur. 2007; 14 (2): 64-70.
Beth RM, Cottrell D. Nursing care of patients receiving: intra-aortic balloon counterpulsation. Crit Care Nurse. 2005; 25(5): 40-49.
Mendoza CA, Manzo CAH. Síndrome compartimental en extremidades. Conceptos actuales. Cir Gen. 2003; 25: 342-348.
Pérez GA, Baranda TFM. Manual de urgencias cardiovasculares. Balón intraaórtico de contrapulsación. 4 ed. México: McGgraw-Hill; 2012.