2002, Number 2
<< Back Next >>
Rev Mex Ing Biomed 2002; 23 (2)
Objective Method for the Evaluation of Visual Dynamic Acuity using Pupillary Responses
Zúñiga LA, Suaste GE
Language: Spanish
References: 11
Page: 109-115
PDF size: 76.63 Kb.
ABSTRACT
The purpose of this work is to evaluate objectively the visual acuity (VA), using optotypes in movement, of a subject with optic correction and without it making use of its pupillary response. To measure the VA, the conditions of luminance and contrast are settled down. Once the conditions of the study are controlled, an optotype in movement is introduced to the subject. The sinusoidal frequency of the optotype is varied starting from 0.1 Hz and gradually increasing, until the subject is not able to distinguish the character of the Snellen chart. The objective VA is obtained using the technique of video-oculography which can detect the pupillary changes by means of images processing. The results obtained by this method, that is, when reflex dilatation of the pupil coincides with the moment in which the subject stops to perceive the optotype, guarantees that this method can be considered as objective for the evaluation of the VA dynamics. In the same way, the results demonstrate that the visual system of an individual to detect, to recognize or to solve details of an image is different if the object or the image is in movement.
REFERENCES
Artigas JM, Capilla P, Pujol J, Felipe A. Óptica Fisiológica Psicofísica de la Visión. Edit. Interamericana Mc Graw-Hill, Madrid, 1995.
Zúñiga A, Suaste E. Sistema para evaluar la agudeza visual basado en patrones en movimiento. II Congreso Latinoamericano de Ingeniería Biomédica, Clave: 00171, La Habana, Cuba, del 23 al 25 de mayo de 2001.
Stark L. Neurological Control Systems, Studies in Bioengineering. Plenum Press, New York, 1968.
Moses RA. Adler´s Physiology of the eye, Clinical Application. C. V. Mosby Company, 1981.
Suaste E, Rivera P, Solis L. Fiber optics and video-oculography associated with pupillary responses and visual evoked potentials for objective perimetry. Journal of Clinical Engineering 1977: 308-315.
Clarke A, Teiwes W, Sherer H. Video-oculography, an alternative method for measurement of three dimensional eye movements. Freie Universitat Berlin, 1989.
Suaste E, Cajica C, Rivera P. Video–oculography for measurement of torsional nystagmus. Pro. of the 15th Ann. Int. Conf. IEEE-EMBS 1993; 15(1): 38-39.
Zubber BL, Semmlow JL, Stark L. Frequency characteristics of the saccadic eye movement. Biophysical Journal, 1968; 8: 1288-1298.
Burr DC. Human sensitivity to flicker and motion. Vision and visual dysfunction, Ed. J.R. Cronly-Dillon. MacMillan Press 1991; 5: 147-159.
Leigh RJ, Zee DS. Ocular Disorders. Vision and visual dysfunction, Ed. J.R. Cronly-Dillon. MacMillan Press 1991; 8: 297-319.