ABSTRACT
Objective: We present the case of a patient who sustained a gunshot wound; the projectile was located in the knee and was arthroscopically removed.
Clinical case: A 31 year-old patient sustained a gunshot wound in the right thigh, right hand and left knee. X-rays revealed the presence of a projectile in the knee, thigh and hand. The projectile was arthroscopically removed.
Discussion: Traumas causing articular wounds of the knee are infrequent. Excluding the most frequent causes of articular wounds, a small percentage of them are due to gunshot wounds. There is consensus around arthroscopy as a technique useful to remove articular foreign bodies; it has advantages over open surgery. This procedure minimizes surgical morbidity, reduces the risk of septic arthritis, synovitis, arthropathy or systemic lead toxicity, and it also hastens the patient’s functional recovery. Knee arthroscopy allows physicians to provide a definitive treatment of these injuries, explore the joint, diagnose associated injuries and perform debridement and articular lavage.
Conclusion: Arthroscopy is an effective tool for the extraction of articular projectiles; it also allows diagnosing and treating associated lesions.
REFERENCES
Parisien JS, Esformes I: The role of arthroscopy in management of low-velocity gunshot wounds of the knee joint. Clin Orthop 1984; 185: 207-13.
Hurst JM, Rybczynski J, Wertheimer SJ: The physics, pathophysiology and management of high velocity gunshot wounds. J Foot Surg 1986; 25: 577-8.
Haspl M, Bojanic I, Pecina M: Arthroscopic retrieval of metal foreign bodies from the knee joint after war wounds. Injury 1996; 27: 177-9.
Lee G, Virkus W, Kapotas J: Arthroscopically assisted minimally invasive intraarticular bullet extraction: Technique, indications and results. Injury 2008; 64: 512-6.
Ganocy K, Lindsey RW: The management of civilian intraarticular gunshot wounds: treatment considerations and proporsal of a classification system. Injury 1998; 29(Suppl 1): SA1-6.
Díaz GC, Beltrán R: Lesiones causadas por proyectil de arma de fuego. Estudio epidemiológico en el Hospital Sharp de Mazatlán, Sinaloa. Acta Ortop Mex 2004; 18(2): 37-40.
Cho MS, Warme WJ: Arthroscopy treatment of a transarticular low- velocity gunshot wound using tractoscopy. Arthroscopy 2002; 18: 532-7.
Sansone V, Mora L, De Spirito D: Arthroscopy retrieval of an unusual foreign body of the knee. Arthroscopy 2002; 18: E6.
Fallon M, Warme W, Bone C: Intraarticular. Knee injection to identify capsular compromise in trauma. Presented at the 68th Annual Meeting of the American Academy of Orthopaedic Surgeons, San Francisco, CA, March 1, 2001.
Tornetta P, Hui RC: Intraarticular findings after gunshot wounds through the knee. J Orthop Trauma1997; 11: 422-4.
Snyder WH, Watkins WL, Whiddon LL, Bone GE: Civilian popliteal artery trauma: An eleven-year experience with 83 injuries. Surgery 1979; 85: 101-8.
Jerosch J: Acute joint infection-diagnosis and treatment. Orthopaede 2004; 33: 1309-18.
Leonard MH: The solution of lead by synovial fluid. Clin Orthop 1969; 64: 255-61.
De Martini J, Wilson A, Powell JS, Powell CS: Lead arthropathy and systemic lead poisoning from an intraarticular bullet. Am J Radiology 2001; 176: 1114.
Linden MA, Manton WI, Stewart M, Thal ER, Feil H. Lead poisoning from retained bullets. Ann Surg 1982; 195: 305-13.
McQuirter JL, Rothenberg SJ, Dinkins GA, Kondrashov V, Manalo M, Todd A. Change in blood lead concentration up to 1 year after a gunshot wound with a retained bullet. Am J Epidemiol 2004; 159: 683-92.