Range of motion of the joint of the hand is necessary to do a quantitative functional evaluation. Mechanical goniometry is the typical procedure to measure finger joints, but this method has several problems; instrument, subjective examiner-dependent, tedious and high time consuming. In this paper, we present the design of a 2D-images prototype video-based movement analysis system to measure the joint of the hand and wrist in space including three perspectives. The instrumentation is centered on glove with markers, each placed on proximal and distal phalanges of the fingers and also the wrist. Hand images are acquired using three digital cameras, a card video and they are processed with Vision Builder. The GUI was designed in LabVIEW platform and its specifications get clinical requirements. The examiner may make quantitative, easy and trustworthy evaluation kinematic of the hand. He can take reliable values because they are between literature ranges. Then, he can do his treatment, surgical and rehabilitation decisions in an objective way. The video-based system to measure the hand’s joints represents a good tool to substitute the manual goniometer.
REFERENCES
Salinas-Tovar S, Hernández-Leyva BE, Marín-Cotoñieto IA, Santos-Celis R, Luna-Pizarro D, López-Rojas P. Workplace accident-related finger-fracture at the Mexican Institute of Social Security. Rev Med Inst Mex Seguro Soc 2007; 45(6): 557-564.
Gordon P. History and physical examination. Editor Elsevier Health Sciences. 2005: 192-195.
Buckup K. Pruebas clínicas para patología ósea, articular y muscular exploraciones, signos, síntomas. Editorial Elsevier España. 2007: 127-141.
Clarkson HM. Proceso evaluativo musculoesquelético. Editorial Paidotribo, 2003: 274-280.
Velázquez A, Merchan E, Hernández L, Urriolagotia G. Rango de movilidad y función descriptiva del dedo índice. Científica Instituto Politécnico Nacional 2007; 11(004): 177-188.
Norkin C, White J. Measurement of joint motion – a guide to goniometry. Editorial F.A Davis Company, USA. 2003: 137-163.
Taboadela C. Goniometría. Una herramienta para la evaluación de las incapacidades laborales. 1ª. Ed. Buenos Aires: Asociart ART, 2007.
Sutherland DH. The evolution of clinical gait analysis: Part II Kinematics. Gait & Posture 2002; 16: 159-179.
Gentner R, Classen J. Development and evaluation of a low-cost sensor glove for assessment of human finger movements in neurophysiological settings. Journal of Neuroscience Methods 2009; 178: 138-147.
Chiu HY, Su FC. The motion analysis system and the maximal area of fingertip motion. Journal of Hand Surgery 1996; 21(B): 604-608.
Chiu H, Su F, Wang, Hsu. The motion analysis system and goniometry of the finger joints. Journal of Hand Surgery 1998; 23: 788.
Rash G, Belliappa P, Wachowiak M, Somia N, Gupta A. A demonstration of the validity of a 3-D video motion analysis method for measuring finger flexion and extension. Journal of Biomechanics 1999; 32(12): 1337-1341.
Sheng-Pin Ho. Three-dimensional finger motion analysis system using videos from multiple cameras. MsD. Thesis, National Cheng Kung University, Department of Computer Science and Information Engineering, 2006.
Hienz H, Grobel K, Offner G. Real-time hand-arm motion analysis using a single video camera. Second IEEE International Conference on Automatic Face and Gesture Recognition 1996: 323.
NI Vision, NI Vision Builder for Automated Inspection Development Toolkit Tutorial. 2009.
Spitaleri CH. Using databases with LabView. LabVIEW User Group Meeting User Manual, 2007.