2002, Number 4
<< Back Next >>
Arch Cardiol Mex 2002; 72 (4)
Mitral valvuloplasty. Comparison of the double balloon versus the single “Nucleus” balloon technique
Ángeles-Valdés J, Uruchurtu CE, Gómez CÁ
Language: Spanish
References: 32
Page: 290-296
PDF size: 159.95 Kb.
ABSTRACT
Mitral stenosis requires mechanical management once the area decreases to critical values. We began practicing mitral valvuloplasty in 1994 with the double balloon technique and, since 1996, we have been performing the procedure using a single balloon called “Nucleus”. We compare the immediate results of both techniques. We included 31 patients divided in two similar groups: group A (double balloon) of 15 patients, average Wilkins score of 7.13 ± .80, mitral valve area pre-valvuloplasty of .83 ± .25 cm
2 and transmitral gradient of 17.06 ± 7.6 mmHg; group B (Nucleus balloon) of 16 patients, Wilkins score of 7.6 ± .71, mitral valve area 1.05 ± .33 cm
2, transvalvular gradient of 14.26 ± 5.00 mmHg. Post-valvuloplasty valvular area increased in group A and group B, respectively, to 1.99 ± .49 cm
2 and 2.67 ± .63 cm
2 (p ‹ .001); gradient decreased to 5.55 ± 2.50 mmHg, and 2.95 ± 2.32 mmHg (p ‹ .001). Increase of mitral insufficiency of one grade was present on one patient of each group; one patient of group A had significant interatrial shunt after the procedure. The mitral valvuloplasty yields better results and is more practical when performed with the Nucleus balloon than with the double balloon.
REFERENCES
Feldman T: Rheumatic Heart disease. Curr Opin Cardiol 1996; 11(2): 126-30.
Pont K, Pretorius MM, Doubell AF, Reuter H: Valvular heart disease associated with systemic lupus erythematosus-the Tygerberg Hospital experience. Cardiovasc J S Afr 2000; 11(3): 138-143.
Amigo-Castañeda MC, Soto-López ME, Espínola-Zavaleta N, Romero-Cárdenas A, Vargas-Barrón J: Valvulopathy in primary antiphospholipid syndrome. Prospective echocardiography study. Gac Med Mex 2000; 136: 3-8.
Lucas G, Ribuilloy C. Epidemiology and etiology of acquired heart valve diseases in adults. Rev Prat 2000; 1; 50(15): 1642-5.
Carabello BA, Crawford FA: Therapy for mitral stenosis comes full circle. N Engl J Med 1994; 331: 1014-5
Inoue K, Owaki T, Kitamura F, Miyamoto N: Clinical application of transvenous mitral comissurotomy by a new balloon cateter. J Thorac Cardiovasc Surg 1984; 87(3): 394-402.
Palacios IF: Farewell to Surgical Mitral Commissurotomy for Many Patients. Circulation 1998; 97: 223-226.
Lung B, Garbarz E, Michaud P, Helous S, Farra B, Berdah P et al: Late results of percutaneous mitral commissurotomy in a series of 1,024 patients: analysis of late clinical deterioration: frequency, anatomical findings, and predictive factors. Circulation 1999; 99: 3272-3278.
Chen C, Cheng TO, for the Multicenter Study Group: Percutaneous balloon mitral valvuloplasty using Inoue technique: a multicenter study of 4,832 patients in China. Am Heart J 1995; 129: 1187–1204.
Martínez Reading J, Cordero Cabra JA, Romero Cárdenas A, Ban Hayashi E, Alvarado Gutiérrez G, Kuri Alfaro J: Valvuloplastía mitral percutánea con balón de Inoue. Experiencia inicial y seguimiento clínico a 3 años en el Instituto Nacional de Cardiología “Ignacio Chávez”. Arch Inst Cardiol Mex 1994; 64(6): 537-42.
Cribier A, Eltchaninoff H, Koning R, Rath PC, Arora R, Imam et al: Percutaneous Mechanical Mitral Commissurotomy UIT a Newly Designed Metallic Valvulotome: Immediate Results of the Initial Experience in 153 Patients. Circulation 1999; 99: 793-799.
Uruchurtu E, Sánchez A, Solís H, Hernández I, García F, Vázquez A et al: Resultados inmediatos de la valvuloplastía mitral percutánea con el balón “Nucleus”. Arch Inst Cardiol Mex 2000; 70: 486-491.
Al Zaibag M, Ribeiro PA, Al Kasab S, Al Fagih MR: Percutaneous double-balloon mitral valvotomy for rheumatic mitral-valve stenosis. Lancet 1986; 1: 757-61.
Gorlin R, Gorlin SG: Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. Am Heart J 1951; 41: 1-29.
Reyes VP, Raju BS, Wynne J, Stephenson LW, Raju R, Fromm BS et al: Percutaneous balloon valvuloplasty compared with open surgical commissurotomy for mitral stenosis. N Engl J Med 1994; 331: 961-7.
Wilkins GT, Weyman AE, Abascal VM, Block PC, Palacios IF: Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. Br Heart J 1988; 60: 299-308.
Hildick-Smith DJ, Taylor GJ, Shapiro LM: Inoue balloon mitral valvuloplasty: long-term clinical and echocardiographic follow-up of a predominantly unfavorable population. Eur Heart J 2000; 21(20): 1690-7.
Miltiadis N, Leon MD, Lari C. Harrell BS, Hector F, Simosa MD, Nasser A, Mahdi MD, Asad Z, Pathan MD, Julio Lopez-Cuellar MD et al: Comparison of immediate and long-term results of mitral balloon valvotomy with the double-balloon versus Inoue techniques. Am J Cardiol 1999; 83(9): 1356-63.
Block PC, Palacios IF, Jacobs ML, Fallon JT: Mechanism of percutaneous mitral valvotomy. Am J Cardiol 1987; 59: 178-179.
Reid CL, Mckay CR, Chandrarantina PAN, Kawanishi DT, Rahimtoola SH: Mechanisms of increase in mitral valve area and influence of anatomic feacturs in double-ballon, cateter ballon valvuloplasty in adults with rheumatic mitral stenosis: A Doppler and two-dimensional echocardographic study. Circulation 1987; 786: 628-636.
Fassbender D, Schmidt HK, Seggewiss H, Mannebach H, Bogunovic N: Diagnosis and differential therapy of mitral stenosis. Herz 1998; 23: 420-428.
Padial LR, Freitas N, Sagie A, Newell JB, Weyman AE, Levine RA, Palacios IF: Echocardiography can predict which patients will develop severe mitral regurgitation after percutaneous mitral valvulotomy. J Am Coll Cardiol 1996; 27(5): 1225-31.
Vahanian A, Michel PL, Cormier B. Percutaneous mitral Valvuloplasty. Rev Prat 1990; 40: 2413-8.
Tuzcu EM, Block PC, Palacios IF: Comparison of early versus late experience with percutaneous mitral balloon valvuloplasty. J Am Coll Cardiol 1991; 17: 1121-4.
Zanchetta M, Onorato E, Rigatelli G, Dimopoulos K, Pedon L, Zennaro M, Maiolino P: Use of Amplatzer septal occluder in a case of residual atrial septal defect causing bidirectional shunting after percutaneous Inoue mitral balloon valvuloplasty. J Invasive Cardiol 2001; 13(3): 223-6.
Kamalesh M, Burger AJ, Shubrooks SJ Jr: The use of transesophageal echocardiography to avoid left atrial thrombus during percutaneous mitral valvuloplasty. Cathet Cardiovasc Diagn 1993; 28(4): 320-2.
Joseph G, Chandy ST, Krishnaswami S, Ravikumar E, Korula RJ: Mechanisms of cardiac perforation leading to tamponade in balloon mitral valvuloplasty. Cathet Cardiovasc Diagn 1997; 42(2): 138-46.
Bharat D: Correspondence: Treatment of Mitral Stenosis. N Engl J Med 1995; 332(11): 748-750.
Mayer IV, Fischer A, Jakob M, Mandinov L, Hug R, Vassalli G, Hess OM: Reversal of increased diastolic stiffness in mitral stenosis after successful balloon valvuloplasty. J Heart Valve Dis 1999; 8: 47-56.
Sajja LR, Mannam GC: Role of closed mitral commissurotomy in mitral stenosis with severe pulmonary hypertension. J Heart Valve Dis 2001; 10(3): 288-93.
Mesan CV, Kapoor A, Sinha N, Kumar AS, Goel PK: Effect of Inoue balloon mitral valvotomy on severe pulmonary arterial hypertension in 315 patients with rheumatic mitral stenosis: immediate and long-term results. J Heart Valve Dis 2000; 9(5): 609-15.
Complications and mortality of percutaneous balloon mitral commissurotomy. A report from the National Heart, Lung, and Blood Institute Balloon Valvuloplasty Registry. Circulation 1992; 85: 2014-24.