2010, Number 4
<< Back Next >>
Acta Ortop Mex 2010; 24 (4)
Evaluation of the results of the treatment of Vancouver B1 periprosthetic fractures and proposed indications for the use of cortical allograft as part of the fixation
Font-Vizcarra L, Muñoz-Mahamud E, Fernández-Valencia JA, Gallart X, Prat S, Riba J
Language: Spanish
References: 23
Page: 215-219
PDF size: 346.28 Kb.
ABSTRACT
Currently there is limited information on the indications for the use of cortical allograft for the treatment of periprosthetic fractures on a stable stem. The purpose of this study was to retrospectively evaluate the treatment and the results obtained in this type of fractures and propose a series of criteria for the use of cortical allograft. Between 2003 and 2008 a total of 31 periprosthetic femur fractures were treated at our institution. Twelve of them were classified as B1: 6 were treated with a Dall-Miles (Stryker
®) system plate and 6 with the same plate supplemented with a structural cortical allograft over the medial cortex of the femur (DM and DM-Allo groups, respectively). An evaluation of the clinical and radiologic results was performed in the latest follow-up available. A patient in the DM-Allo group had rupture of a screw and 10° varization; the fracture healed despite this and the patient had a satisfactory clinical course. The Oxford Hip Score was 9 points lower in the DM group compared with the DM-Allo group, and the EQ-5D health scale was 0.10 better for the DM group. The DM-Allo group had a longer hospital stay and more transfusion-related requirements. We think that the patients with clinical or radiologic criteria of osteoporotic bone may benefit from the use of a cortical allograft to favor healing and increase the bone stock. However, those advantages should be weighed considering the higher risk of surgical-related morbidity associated with the surgical insult.
REFERENCES
Giannoudis PV, Kanakaris NK, Tsiridis E: Principles of internal fixation and selection of implants for periprosthetic femoral fractures. Injury 2007; 38: 669-87.
Tsiridis E, Krikler S, Giannoudis PV: Periprosthetic femoral fractures: current aspects of management. Injury 2007; 38: 649-50.
Duncan CP, Masri BA: Fractures of the femur after hip replacement. Instr Course Lect 1995; 44: 293-304.
Asociación Española de Bancos de Tejidos. Estándares de la Asociación Española de Bancos de Tejidos. Ed. 2008 http://www.aebt.org/ (accessed 15/01/08).
Hirna MYJ, Krusiusb T: Retesting of bone donors 2 months after donation guarantees sufficient safety of bone allografts Issue. Acta Orthopaedica 1998; 69: 566-9.
Dennis MG, Simon JA, Kummer FJ, Koval KJ, DiCesare PE: Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J Arthroplasty 2000; 15: 523-8.
Dawson J, Fitzpatrick R, Carr A, Murray D: Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg Br 1996; 78: 185-90.
Herdman M, Badia X, Berra S: EuroQol-5D: A simple alternative for measuring health-related quality of life in primary care. Aten Primaria 2001; 28: 425-30.
Badia X, Roset M, Montserrat S, Herdman M, Segura A: The spanish version of EuroQol: a description and its applications. European Quality of Life scale. Med Clin 1999; 112 Suppl 1: 79-85.
Old AB, McGrory BJ, White RR, Babikian GM: Fixation of Vancouver B1 peri-prosthetic fractures by broad metal plates without the application of strut allografts. J Bone Joint Surg Br 2006; 88(11): 1425-9.
Jensen JS, Barfod G, Hansen D, Larsen E, Linde F, Menck H, Olsen B: Femoral shaft fracture after hip arthroplasty. Acta Orthop Scand 1988; 59: 9-13.
Tower SS, Beals RK: Fractures of the femur after hip replacement: the Oregon experience. Orthop Clin North Am 1999; 30: 235-47.
Noorda RJ, Wuisman PI: Mennen plate fixation for the treatment of periprosthetic femoral fractures: a multicenter study of thirty-six fractures. J Bone Joint Surg Am 2002; 84(12): 2211-5.
De Ridder VA, de Lange S, Koomen AR, Heatley FW: Partridge osteosynthesis: a prospective clinical study on the use of nylon cerclage bands and plates in the treatment of periprosthetic femoral shaft fractures. J Orthop Trauma 2001; 15(1): 61-5.
Barden B, Ding Y, Fitzek JG, Loer F: Strut allografts for failed treatment of periprosthetic femoral fractures: good outcome in 13 patients. Acta Orthop Scand 2003; 74: 146-53.
Wang JW, Wang CJ: Periprosthetic fracture of the femur after hip arthroplasty: The clinical outcome using cortical strut allografts. J Orthop Surg 2000; 8: 27-31.
Tsiridis E, Haddad FS, Gie GA: Dall-Miles plates for periprosthetic femoral fractures. A critical review of 16 cases. Injury 2003; 34: 107-10.
Wilson D, Frei H, Masri BA, Oxland TR, Duncan CP: A biomechanical study comparing cortical onlay allograft struts and plates in the treatment of periprosthetic femoral fractures. Clin Biomech 2005; 20: 70-6.
Ricci WM, Bolhofner BR, Loftus T, Cox C, Mitchell S, Borrelli J, Jr: Indirect reduction and plate fixation, without grafting for periprosthetic femoral shaft fractures about a stable intramedullary implant. J Bone Joint Surg Am 2005; 87: 2240-45.
Sandhu R, Avramidis K, Johnson-Nurse C: Dall-Miles cable and plate fixation system in the treatment of periprosthetic femoral fractures: a review of 20 cases. J Orthop Surg (Hong Kong) 2005; 13(3): 259-66.
Chakravarthy J, Bansal R, Cooper J: Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: a report on 12 patients. Injury 2007; 38(6): 725-33.
Buttaro MA, Farfalli G, Paredes Núñez M, Comba F, Piccaluga F: Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone Joint Surg Am 2007; 89(9): 1964-9.
Bhattacharyya T, Chang D, Meigs JB, Estok DM, Malchau H: Mortality after periprosthetic fracture of the femur. J Bone Joint Surg Am 2007; 89(12): 2658-62.