2008, Number 6
<< Back Next >>
Rev Mex Oftalmol 2008; 82 (6)
Acortamiento del tubo de la válvula de Ahmed mediante técnica ab interno
Jiménez-Román J, Castañeda-Díez R, Velasco GG, Paczka ZJA
Language: Spanish
References: 11
Page: 366-368
PDF size: 78.38 Kb.
ABSTRACT
The Ahmed valve implant is a very important tool in difficult glaucoma patients and it is an alternative in patients who do not respond to a common treatment. In the other hand, there are complications related to the implant like choroidal detachment, hiphema, hipotony, encapsulated bleb and tube malposition. When the tube lengh is the cause of enthotelial touch, shortening the tube is the rule to avoid endothelial damage. We want to report a new technique to shortening the tube lengh, in patients with Ahmed valve implant.
REFERENCES
Hwang JH, Kee C. The effect of surface area expansion UIT pericardial membrane (preclude) in Ahmed glaucoma valve implant surgery. J Glaucoma 2004; 13:335-339.
Montañez SJ, Laso E, Suñer M, Amaya C. Ahmed drainage device implant. Our experience between 1995 and 2003. Arch Soc Esp Oftalmol 2005; 80(4):239-44.
Guangxian GT, Fanrong FM y cols. Glaucoma valve devices for refractory glaucoma following vitrectomy, Zhonghua Yan Ke Za Zhi 2002; 38(2):90-93.
Coleman AL, Hill R, Wilson MR y cols. Initial clinical experience with the Ahmed glaucoma valve implant. Am J Ophthalmol 1995; 120:123.
Gil F, Salinas E y cols. Manual de Terapéutica Médico-Quirúrgica. Ed Ixel, México. 2002
Zalloum JN, Ahuja RM, Shin D y cols. Assessment of corneal decompensation in eyes having undergone Molteno shunt procedures compared to eyes having undergone trabeculectomy. CLAO J 1999; 25:57.
Billson F, Thomas R, Grigg J. Resiting Molteno tubes. Ophthalmic Surg Lasers 1996; 27:801.
Allinson RW: Paralimbal compression suture for Molteno implants. Ophthalmol Surg 1991; 22:750.
Rapuano CJ, Schmidt CM, Cohen EJ y cols. Results of alloplastic tube shunt procedures before, during, or after penetrating keratoplasty. Cornea 1995; 14:26.
Al-Torbak AA, Edward DP y cols. Transcorneal tube erosion of an Ahmed valve implant in a child. Arch Ophthalmol 2001; 119(10):1558-9
Asrani S, Herndon L, Allingham RR. A newer technique for glaucoma tube trimming. Arch Ophthalmol. 2001; 21:1324-1326.