2008, Number 1
<< Back Next >>
Cir Cir 2008; 76 (1)
Refractive state in patients undergoing cataract phacoemulsification in unusual situations
Ruiz-Morfín I, Bustos-Zepeda M, Díaz-Jiménez JO, Fuente-Torres MA
Language: Spanish
References: 29
Page: 5-12
PDF size: 92.61 Kb.
ABSTRACT
Background: We undertook this study to determine the refractive state in patients who underwent non-complicated phacoemulsification in unusual situations.
Methods: This was a clinical, open, transversal, prospective and comparative study. Patients had the following conditions: congenital cataracts, hyperopic, myopic, and emetrophic with previous corneal transplantation or vitreous cavity filled with silicone oil.
Results: Thirty six eyes were included in our study vs. control group (52 emetrophic eyes). There was no statistical significance in spherical equivalent 6 weeks postoperatively, with 59% of patients within ±1 D, 73% ±2 D and 28% ± 2 D.
Conclusions: Refractive state was favorable with an average of 0.96 D ± 6.27.
REFERENCES
Gilbert C. La importancia de la atención ocular primaria. Rev Salud Ocular Comun 2006;1:1:3-4.
2. Thylefors B. Una iniciativa global para la eliminación de la ceguera evitable. Rev Salud Ocular Comun 2006;1:1:7-9.
3. Hill W, Fraizer S. Mediciones complejas de la longitud axial y cálculos extraordinarios del poder de los cristalinos intraoculares. Focal Points 2003;2:9:1-20.
4. Eleftheriadis H. IOL master biometry: refractive results of 100 consecutive cases. Br J Ophthalmol 2003;87:960-963.
5. Hamilton D, Hardten D. Cataract surgery in patients with prior refractive surgery. Curr Opin Ophthalmol 2003;14:44-53.
6. Mesa J, Marti T, Arruga J. Cálculo del poder dióptrico de la lente intraocular (lio) tras cirugía refractiva. Arch Soc Española Oftalmol 2005;12:355-361.
7. Feiza V, Mannisb M. Intraocular lens power after corneal refractive surgery. Curr Opin Ophthalmol 2004;15:4:342-349.
8. Seitz B, Langenbucher A. Intraocular lens calculations status after corneal refractive surgery. Curr Opin Ophthalmol 2000;11:35-46.
9. Pérez-Silguero D, Pérez-Silguero MA, Pérez-Hernández F. Cálculo de lente intraocular en casos complicados: el método Silguero. Arch Soc Esp Oftalmol 2005;10:453-461.
10. Ahmadieh H, Javadi M. Intra-ocular lens implantation in children. Curr Opin Ophthalmol 2001;12:30-34.
11. Scout K, Hofmeister E. Intraocular lens power calculation for children. In: Pediatric Cataract Surgery. Philadelphia: Lippincott Williams & Wilkins; 2005. pp. 30-37.
12. Tromans C, Haigh P, Biswas S, Lloyd C. Accuracy of intraocular lens power calculation in paediatric cataract surgery. Br J Ophthalmol 2001;85:939-941.
13. Charlton J. Cataract surgery and lens implantation. Curr Opin Ophthalmol 2000;11:1-2.
14. Langenbucher A, Haigis W, Seitz B. Difficult lens power calculations. Curr Opin Ophthalmol 2004;15:1-9.
15. Vetrugno M, Cardascia N, Cardia L. Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant. Br J Ophthalmol 2000;84:113-116.
16. Findl O. Biometry and intraocular lens power calculation. Curr Opin Ophthalmol 2005;15:61-64.
17. Elder J. Predicting the refractive outcome after cataract surgery: the comparison of different hilos and SRK-II v SRK-T. Br J Ophthalmol 2002;86:620-622.
18. Colette S, Tsang M, Chong G. Intraocular lens power calculation formulas in Chinese eyes with high axial miopia. J Cataratct Refract Surg 2003;29:1358-1364.
19. Kaiser-Lomparte, Chávez M, Morales G. Resultados refractivos poscirugía de catarata en pacientes miopes. Rev Mex Oftalmol 2006;80:297-300.
20. Hug T. Use of the aphakic refraction in intraocular lens (IOL) power calculations for secondary IOLs in pediatric patients. J Pediatr Ophthalmol Strabismus 2004;41:209-211.
21. Lopez G. Estudo refracional em crianzas pseudifácicas. Arq Bras Oftalmol 2005;68:373-375.
22. Acevedo-González, Ordaz-Favila, Juárez-Echenique. Opacificación de la cápsula posterior con lentes intraoculares plegables en cirugía de catarata pediátrica. Rev Mex Oftalmol 2006;80:246-253.
23. Eleftheriadis H. Sciscio A, Ismail A, Hull CC, Liu C. Primary polipseudophakia for cataract surgery in hypermetropic eyes: refractive results and long term stability of the implants within the capsular bag. Br J Opthalmol 2001;85;11:1198-1202.
24. Ghoraba H, El-Dorghamy AA, Atia AF, Yassin AA. The problems of biometry in combined silicone oil removal and cataract extraction: a clinical trial. Retina 2002;22:589-596.
25. Habibabadi H, Hashemi H, Jalali K. Refractive outcome of silicone oil removal and intraocular lens implantation using laser interferometry. Retina 2005;25:162-166.
26. Takei K, Sekine Y, Okamoto F, Hommura S. Measurement of axial length of eyes with incomplete filling of silicone in the vitreous cavity using x ray computed tomography. Br J Ophthalmol 2002;87:47-50.
27. Andrean S, Reilly C, Mannis M. Intraocular lens calculation in a patient with previous penetrating keratoplasty and lasik. Cornea 2005;24:629:631.
28. Urrutia B, Matiz M, Morales G, Chávez M. Resultados refractivos en pacientes operados de catarata con antecedente de cirugía refractiva corneal. Rev Mex Oftalmol 2006;80:312-317.
29. Argento C, Cosentino M, Badoza D. Intraocular lens power calculation after refractive surgery. J Cataract Refract Surg 2003;29:1346-1351.