ABSTRACT
Background: Scintigraphy is the reference method for the assessment of gastric emptying (GE), however breath analyses involving stable isotopes are nowadays considered good alternatives for this purpose, given their safety and non-invasiveness.
Aim: Correlate the mean time (t
1/2) of GE of solids assessed by scintigraphy versus the time obtained by breath test involving octanoic acid labelled with (
13C-OABT).
Methods: GE of solids was simultaneously measured by scintigraphy and by the
13C-PAO test after administration of meal test. It was content 240 ml of tea and an egg sandwich (380 Kcal) labelled with 0.5 mCi
99mTc-pertecnatat and 100 mg of
3C-octanoic acid.
Results: Ten healthy subjects were included, age 31 ± 3.9 yrs. A significative correlation of the t
1/2 of GE between scintigraphy and 13C-OABT with its conventional formula (r = 0.68, p = 0.0297) and “Mayo Clinic model” (r = 0.88, p = 0.0006) was found.
Conclusion: These results confirm the correlation between GE measurements with scintigraphy and
13C-OABT.
REFERENCES
Maurer AH, Parkman HP, Knight LC, Fisher RS. Scintigraphy. In: Schuster MM, Crowell MD, Koch KL (eds.). Schuster atlas of gastrointestinal motility in health and disease second edition. London; BC Decker; 2002, p. 171-84.
Ghoos YF, Maes BD, Geypens BJ, Mys G, Hiele MI, Rutgeerts PJ, Vantrapen G. Measurement of gastric emptying rate of solids by means of a carbon-labeled octanoic acid breath test. Gastroenterology 1993; 104: 1640-7.
Camilleri M, Hasler W, Parkman HP. Measurement of gastrointestinal motility in the GI laboratory. Gastroenterology 1998; 115: 747-62.
Bach AC, Babayan VK. Medium chain triglicerides: an update. Am J Clin Nutrition 1982; 36: 950-62.
Lacroix M, Mosora F, Pontus M. Glucose naturally labeled with carbon 13 used for metabolic studies in man. Science 1973; 181: 445-8.
Kim DY, Camilleri M. Stable isotope breath test and gastric emptying. In: Schuster MM, Crowell MD, Koch KL (eds.). Schuster atlas of gastrointestinal motility in health and disease second edition. London; BC Decker; 2002, p. 203-18.
Vantrappen G. Methods to Study Gastric Emptying. Dig Dis Sci 1994; 39: 91S-94S.
Maes BD, Hiele MI, Geypens BJ, Rutgeerts PJ, Ghoos YF, Vantrappen G. Pharmacological modulation of gastric emptying rate of solids as measured by the carbon labelled octanoic acid breath test: influence of erythromycin and propantheline. Gut 1994; 35: 333-77.
Gonlachanvit S, Chey WD, Goodman KJ, Parkman HP. Effect of meal size and test duration on gastric emptying and gastric myoelectrical activity as determined with simultaneous [13C]octanoate breath test and electrogastrography in normal subjects using a muffin meal. Dig Dis Sci 200; 46: 2643-50.
Ziegler D, Schadewaldt P, Pour Mirza A, Piolot R, Schommartz B, Reinhardt M, Vosberg H, Brosicke H, Gries FA. [13C]octanoic acid breath test for non-invasive assessment of gastric emptying in diabetic patients: validation and relationship to gastric symptoms and cardiovascular autonomic function. Diabetologia 1996; 39: 823-30.
Gonlachanvit S, Hsu CW, Boden GH, Knight LC, Maurer AH, Fisher RS, Parkman HP. Effect of altering gastric emptying on postprandial plasma glucose concentrations following a physiologic meal in type-II diabetic patients. Dig Dis Sci 2003; 48: 488-97.
Pozler O, Neumann D, Vorisek V, Bukac J, Bures J, Kokstein Z. Development of gastric emptying in premature infants. Use of the 13C-octanoic acid breath test. Nutrition 2003; 19: 593-6.
Choi MG, Camilleri M, Burton DD, Zinsmeister AR, Forstrom LA, Nair KS. [13C]octanoic acid breath test for gastric emptying of solids: accuracy, reproducibility, and comparison with scintigraphy. Gastroenterology 1997; 112: 1155-62.
Katz J. Determination of gluconeogenesis in vivo with 14C-labeled substrates. Am J Physiol 1985; 248: R391-R399.
Maes BD, Ghoos YF, Geypens BJ, Hiele MI, Rutgeerts PJ. Relation between gastric emptying rate and energy intake in children compared with adults. Gut 1995; 36: 183-8.
Delbende B, Perri F, Couturier O, Leodolter A, Mauger P, Bridgi B, Bizais Y, des Varannes SB, Andriulli A, Galmiche JP. 13C-octanoic acid breath test for gastric emptying measurement. Eur J Gastroenterol Hepatol 2000; 12: 85-91.
Barnett C, Snel A, Omari T, Davidson G, Haslam R, Butler R. Reproducibility of the 13C-octanoic acid breath test for assessment of gastric emptying in healthy preterm infants. J Pediatr Gastroenterol Nutr 1999; 29: 26-30.
Siegel J, Urbain J, Alder L, Charkes N, Maurer H, Krevsky B, et al. Biphasic nature of gastric emptying. Gut 1988; 29: 85-89.
Haycock Gb, Schuartz GJ, Wisotsky DH. Gastric metod for measuring body surface area: a heigth-weight formula vallidated in infants, children and adults. J Pediatr 1978;93:62-66.
Braden B, Adams S, Duan LP, et al. The [13C] acetate breath test accurately reflects gastric emptying of liquids in both liquid and semisolid test meals. Gastroenterol 1995; 108: 1048-55.
Choi MG, Camilleri M, Burton DD, Zinsmeister AR, Forstrom LA, Sreekumaran NK. Reproducibility and simplification of [13C]-octanoic acid breath test for gastric emptying of solids. Am J Gastroenterol 1998; 93: 92-8.
Lee JS, Camilleri M, Zinsmeister AR, Burton DD, Choi MG, Nair KS, Verlinden M. Toward office-based measurement of gastric emptying in symptomatic diabetics using 13C octanoic acid breath test. Am J Gastroenterol 2000; 95: 2751-61.