2022, Number 2
Ultrasonographic imaging of the optic nerve-sheath complex in intracranial hypertension
Language: Spanish
References: 18
Page: 1-12
PDF size: 367.72 Kb.
ABSTRACT
Objective: To determine the relationship between the thickness of the optic nerve- sheath complex as measured by ultrasound and intracranial hypertension.Methods: A descriptive and longitudinal observational study was performed in 144 orbits of 72 patients with a clinical diagnosis of intracranial hypertension. Once clinical improvement was achieved, orbital ultrasound was performed at the beginning of the diagnosis, which allowed measuring the meningeal sheath, the optic nerve, the optic nerve-sheath complex and the height of the papilla.
Results: In all cases the initial thickness of the sheath was ≥ 3 mm, that of the optic nerve-sheath complex > 5 mm, and the height of the papilla > 0.8 mm, while that of the optic nerve did not exceed 3 mm. After reaching clinical improvement, a decrease in all these variables was demonstrated, with the exception of the optic nerve, whose diameter was almost unchanged. Some differences between the first and second ultrasound measurements were statistically significant.
Conclusion: Therefore, this procedure is ratified as part of the full neurological monitoring in patients with suspected or confirmed intracranial hypertension.
REFERENCES
Lee S, Jeon J, Lee H, Ho J, Seo M, Byoun H, et al1. . Optic nerve sheath diameter threshold by ocular ultrasonography for detection of increased intracranial pressure in Korean adult patients with brain lesions. Medicine (Baltimore) 2016 [acceso 21/05/2021];95(41):5061. Disponible en: Disponible en: https://pubmed.ncbi.nlm.nih.gov/27741121/ 1.
Sánchez-Torres C, Urías-Romo E, Martínez F. Diámetro de la vaina del nervio óptico y tomografía axial computada en traumatismo craneoencefálico como predictor de hipertensión intracraneal. Rev Med UAS 2017 [acceso 21/05/2021];7(4):222-30 Disponible en: http://dx.doi.org/10.28960/revmeduas.2007-8013.v7.n4.0052.
Sosa Remón A, Boch Rodríguez W, Jerez Álvarez AE, Remón Chávez CE, Álvarez Santisteban OJ. Anatomía ultrasonográfica del diámetro de la vaina del nervio óptico en el monitoreo de la presión intracraneal. Morfovirtual 2020 [acceso 21/05/2021];1-17. Disponible en: Disponible en: http://morfovirtual2020sld.cu 6.
Díaz-Águila HR, Cabrera-Domínguez A. Informe preliminar sobre el empleo de la ecografía de la vaina del nervio óptico para el diagnóstico de hipertensión intracraneana en pacientes con enfermedad cerebrovascular. Univ Méd Pinareña 2021 [acceso 28/05/2021];17(2):e678. Disponible en: Disponible en: https://file:///C:/Users/laurap/AppData/Local/Temp/678-2646-1-PB.pdf 7.
De Saz Saucedo P. Tesis doctoral. Precisión diagnóstica de la medición ecográfica del grosor de la vaina del nervio óptico en la hipertensión intracraneal idiopática. Facultad de Medicina de Albacete. Universidad de Castilla La Mancha. 2018 [acceso 28/05/2021]. Disponible en: Disponible en: https://1library.co/document/yjedl96q-precision-diagnostica-medicion-ecografica-optico-hipertension-intracraneal-idiopatica.html 8.
Ponce de León GM. Medición del diámetro de la vaina del nervio óptico con ultrasonido ocular y su correlación con hallazgos tomográficos de edema cerebral en pacientes con traumatismo craneoencefálico. JRICS. 2019 [acceso 28/05/2021];15(8)1-18. Disponible en: Disponible en: https://dialnet.unirioja.es/servlet/articulo?codigo=6779632 9.
Carrillo Esper R, Flores Rivera OI, Peña Pérez CA, Carrillo Córdova LD, Carrillo Córdova JR, Carrillo Córdova CA, et al10. . Evaluación ultrasonográfica del diámetro de la vaina del nervio óptico (DVNO) para la medición de la presión intracraneana (PIC): a propósito de un caso. Rev Mex Anest 2014[acceso 28/05/2021];150(2):165-70. Disponible en: Disponible en: https://dialnet.unirioja.es/servlet/articulo?codigo=4703010 10.
Del Saz Saucedo P, Redondo González O, Mateu Mateu A, Huertas Arroyo R, García Ruiz R, Botia Paniagua E. Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension. Journal of the Neurological Sciences 2016 [acceso 28/05/2021];361:122-27. Disponible en: Disponible en: https://pubmed.ncbi.nlm.nih.gov/26810528/ 11.
García Molina J. Utilidad diagnóstica de la ecografía de vaina de nervio óptico (EVNO), como método no invasivo para la detección de hipertensión intracraneal. Estudio prospectivo de 95 mediciones comparado con monitoreo invasivo en Chile. Rev Chil Neurocirugía 2019 [acceso 28/05/2021];45:38-44. Disponible en: https://doi.org/10.36593/rev.chil.neurocir.v45i1.912.
Islas Ávila RE, Coria Ladrón de Guevara LV, De Jesús Montelongo F, Reyes Pérez MM, Carmona Domínguez A, Suárez Suárez A. Medición del diámetro de la vaina del nervio óptico por ultrasonografía versus tomografía simple de cráneo en pacientes con trauma craneoencefálico. Med Crit. 2020 [acceso 28/05/2021];34(4):221-30. Disponible en: Disponible en: https://www.medigraphic.com/cgi-bin/new/resumen.cgi?IDARTICULO=95877 14.
Amini A, Kariman H, Arhami-Dolatabadi A, Hatamabadi HR, Derakhshanfar H, Mansouri B, et al15. . Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure. Am J Emerg Med 2013 [acceso 28/05/2021];31:236-39. Disponible en: Disponible en: https://pubmed.ncbi.nlm.nih.gov/22944553/ 15.
Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Ultrasonograpy of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med 2011 [acceso 28/05/2021];37(7):1059-68. Disponible en: Disponible en: https://pubmed.ncbi.nlm.nih.gov/21505900/ 16.
Bauerler J, Locner P, Kaps M, Nedelman M. Intra and interobserver reliability of sonographic assessment of de optic nerve sheath diameter in healthy adult. J Neuroimaging. 2012 [acceso 28/05/2021];22(1):42-5. Disponible en: Disponible en: https://www.scielo.br/scielo.php?pid=S003472802019000200122&script=sci_arttext&tlng=en 18.