2021, Number 3
<< Back Next >>
Rev Mex Patol Clin Med Lab 2021; 68 (3)
Pre-analytical phase: ''The solution is in our hands''
Sánchez DJS, Monares ZE, Peniche MKG, Martínez REA, Martínez AFR, Terán SJM
Language: Spanish
References: 26
Page: 118-122
PDF size: 216.72 Kb.
ABSTRACT
The preanalytical phase of blood gas analysis is the stage in which the supplies are prepared, the sample is taken and transported for analysis (analytical phase) and interpretation (postanalytical phase). In the so-called "laboratory errors" a significant fraction occurs outside the laboratory. Of 100% of the errors that occur in laboratory studies, the preanalytical phase occupies 75%, the analytical 4% and the postanalytical 21%. The preanalytical phase is characterized by four steps: 1) preparation, 2) sample collection, 3) sample storage and 4) sample transport, each one prone to multiple errors, due to its "obviousness". The preanalytical phase is the most susceptible to errors, which translate into time and money for the institutions. But the most important thing is that these errors cause "discomfort", complications or wrong therapeutic actions in patients.
REFERENCES
Bloom BM, Grundlingh J, Bestwick JP, Harris T. The role of venous blood gas in the emergency department: a systematic review and meta-analysis. Eur J Emerg Med. 2014; 21 (2): 81-88.
Casagranda I. Point-of-care testing in critical care: the clinician's point of view. Clin Chem Lab Med. 2010; 48 (7): 931-934.
Plebani M, Laposata M, Lundberg GD. The brain-to-brain loop concept for laboratory testing 40 years after its introduction. Am J Clin Pathol. 2011; 136 (6): 829-833.
Baird G. Preanalytical considerations in blood gas analysis. Biochem Med (Zagreb). 2013; 23 (1): 19-27.
Cortés-Telles A, Gochicoa-Rangel LG, Pérez-Padilla R, Torre-Bouscoulet L. Gasometría arterial ambulatoria. Recomendaciones y procedimiento. Neumol Cir Torax. 2017; 76 (1): 44-50.
Guder WG. History of the preanalytical phase: a personal view. Biochem Med (Zagreb). 2014; 24 (1): 25-30.
Bonini P, Plebani M, Ceriotti F, Rubboli F. Errors in laboratory medicine. Clin Chem. 2002; 48 (5): 691-698.
Kumar A, Kushwah S, Sahay S. Effect of extra amount of heparin in syringe and its effect on arterial blood gas analysis. EJPMR. 2015; 2 (6): 290-293.
Green SF. The cost of poor blood specimen quality and errors in preanalytical processes. Clin Biochem. 2013; 46 (13-14): 1175-1179.
NCCLS. Procedures for the collection of diagnostic blood specimens by venipuncture; approved standard. 5th edition. USA: NCCLS; 2003.
Rodríguez-Fraga O, Navarro-Segarra X, Galán-Ortega A, Rodríguez-Cantalejo F, Gómez-Rioja R, Altimira-Queral L et al. Recomendaciones preanalíticas para la medición del equilibrio ácido-base y los gases en sangre. Recomendación (2018). Rev Lab Clin. 2019; 12 (4): e66-e74.
Sánchez JS, Martínez EA, Peniche KG, Monares E, Del Carpio L, Pérez OR et al. Equilibrio ácido base en el adulto mayor. Rev Nefrol Dial Traspl. 2019; 39 (3): 213-223.
Burnett RW, Covington AK, Fogh-Andersen N, Külpmann WR, Maas AH, Müller-Plathe O et al. International Federation of Clinical Chemistry (IFCC). Scientific Division. Committee on pH, blood gases and electrolytes. Approved IFCC recommendations on whole blood sampling, transport and storage for simultaneous determination of pH, blood gases and electrolytes. Eur J Clin Chem Clin Biochem. 1995; 33 (4): 247-253.
Kennedy C, Angermuller S, King R, Noviello S, Walker J, Warden J et al. A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples. J Emerg Nurs. 1996; 22 (6): 566-569.
WHO guidelines on drawing blood: Best practices in phlebotomy. Arterial blood sampling. Geneva, Switzerland: World Health Organization; 2010.
Lippi G, Salvagno GL, Montagnana M, Brocco G, Guidi GC. Influence of hemolysis on routine clinical chemistry testing. Clin Chem Lab Med. 2006; 44 (3): 311-316.
Fang L, Fang SH, Chung YH, Chien ST. Collecting factors related to the haemolysis of blood specimens. J Clin Nurs. 2008; 17 (17): 2343-2351.
Ogiso T, Iwaki M, Yamamoto M. Hemolysis induced by benzyl alcohol and effect of the alcohol on erythrocyte membrane. Chem Pharm Bull (Tokyo). 1983; 31 (7): 2404-2415.
Tamechika Y, Iwatani Y, Tohyama K, Ichihara K. Insufficient filling of vacuum tubes as a cause of microhemolysis and elevated serum lactate dehydrogenase levels. Use of a data-mining technique in evaluation of questionable laboratory test results. Clin Chem Lab Med. 2006; 44 (5): 657-661.
World Health Organization (WHO). Use of anticoagulants in diagnostic laboratory investigations. WHO/DIL/LAB/99.1-Rev.2. Geneva: WHO; 2002.
Clinical and Laboratory Standards Institute. Blood gas and pH analysis and related measurements; Approved Guideline. 2nd edition. CLSI document C46-A2. Pennsylvania, USA: Clinical and Laboratory Standards Institute Wayne; 2009.
Hedberg P, Majava A, Kiviluoma K, Ohtonen P. Potential preanalytical errors in whole-blood analysis: effect of syringe sample volume on blood gas, electrolyte and lactate values. Scand J Clin Lab Invest. 2009; 69 (5): 585-591.
Recomendaciones de la Sociedad Brasileña de Patología Clínica/Medicina Laboratorial para la extracción de sangre venosa. 2ª edición. Brasil: Editorial Manole Ltda; 2009.
Dukic L, Kopcinovic LM, Dorotic A, Barsic I. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Biochem Med (Zagreb). 2016; 26 (3): 318-336.
Schmidt C, Müller-Plathe O. Stability of pO2, pCO2 and pH in heparinized whole blood samples: influence of storage temperature with regard to leukocyte count and syringe material. Eur J Clin Chem Clin Biochem. 1992; 30 (11): 767-773.
Biswas CK, Ramos JM, Agroyannis B, Kerr DN. Blood gas analysis: effect of air bubbles in syringe and delay in estimation. Br Med J (Clin Res Ed). 1982; 284 (6320): 923-927.