2021, Number 3
COVID-19 rapid test validation. Isla de la Juventud, Cuba
Language: Spanish
References: 23
Page: 105-114
PDF size: 473.92 Kb.
ABSTRACT
Having diagnostic methods that meet certain attributes is vital to guide health decisions, the current context warrants it. In order to validate the capacity of two rapid tests to detect antibodies due to SARS-CoV-2 infection in Isla de la Juventud, Cuba, from April to May 2020, a descriptive cross-sectional evaluation study was carried out. Rapid tests: Wondfo (SARS-CoV-2 antibody test) and Lungene covid-19 IgG/IgM, were compared to the real-time polymerase chain reaction test. Two homogeneous samples of 250 each were constructed, determining validation indicators. Sensitivity values of 6.6% and 8.3% respectively were obtained for each test, while the specificity was higher for Wondfo (95%). The positive predictive values were very low, the negative ones were adequate, higher in Lungene with 94.8%. Likelihood ratio values were classified as useless. In different scenarios in terms of symptomatic cases, sensitivity of 50% was reached in an interval of 1 to 7 days for Wondfo. The area under the ROC curve for Wondfo was 0.50 (95% CI = 0.46-0.55) and 0.46 for Lungene (95%CI = 0.38-0.55). The kappa index for Wondfo was 0.025 and 0.010 for Lungene. The rapid tests explored showed very low sensitivity, positive predictive value, and inadequate likelihood ratio. The global validity of the tests did not demonstrate a good diagnostic performance, marked by the value of the area under the ROC curve. The degree of agreement was poor.REFERENCES
Organización Mundial de la Salud Asamblea Mundial de la Salud, 70. Examen del Marco de Preparación para una Gripe Pandémica: informe de la Directora General. Ginebra: Organización Mundial de la Salud; 2017. Disponible en:https://apps.who.int/iris/bitstream/handle/10665/274775/A70_17sp.pdf?sequence=1&isAllowed=y.(Consultado en línea: 20 de mayo de 2020).
Mendoza JL, Beltrán N, Estrada VHN, Bolaños ER, Gómez CP, Rebolledo CE, et al. Declaración de consenso en medicina crítica para la atención multidisciplinaria del paciente con sospecha o confirmación diagnóstica de COVID-19. Acta Colomb de Cuid Intensivo. 2020; 20(4):287-333. doi: https://10.1016/j.acci.2020.04.003.
Organización Panamericana de la Salud/Organización Mundial de la Salud. Actualización epidemiológica: Enfermedad por Coronavirus (COVID-19). 14 de abril de 2021. Washington DC: OPS/OMS. Disponible en: https://www.who.int/docs/default-source/coronaviruse/situation-reports/20200615-covid-19-sitrep-147.pdf?sfvrsn=2497a6054.
Vizcaíno-Salazar GJ. Importancia del cálculo de la sensibilidad, la especificidad y otros parámetros estadísticos en el uso de las pruebas de diagnóstico clínico y de laboratorio. Medicina y Laboratorio. 2017; 23(7-8):365-86. Disponible en: http://docs.bvsalud.org/biblioref/2018/05/883697/importancia-calculo-sensibilidad-y-especifidad.pdf. (Consultado en línea: 15 de mayo de 2020).
Manterola C, Grande L, Otzen T, García N, Salazar P, Quiroz G. Confiabilidad, precisión o reproducibilidad de las mediciones. Métodos de valoración, utilidad y aplicaciones en la práctica clínica. Rev Chilena Infectol. 2018;35(6):680-8. Disponible en: https://scielo.conicyt.cl/pdf/rci/v35n6/0716-1018-rci-35-06-0680.pdf. (Consultado en línea: 25 de mayo de 2020).
Liu L, Liu W, Zheng Y, Jiang X, Kou G, Ding J, et al. A preliminary study on serological assay for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in 238 admitted hospital patients. Microb Infect. 2020;22(4-5):206-11. doi: https://10.1016/j.micinf.2020.05.008. (Consultado en línea: 15 de mayo de 2020).
Sociedad Española de Inmunología. Utilidad de la determinación de anticuerpos anti SARS-CoV-2, propuesta de implementación como prueba diagnóstica, pronóstica y de desarrollo de inmunidad protectora Versión 01/2. Abril 2020. Barcelona: Sociedad Española de Inmunología;2020. Disponible en: https://www.inmunologia.org/Upload/Documents/1/5/2/1520.pdf. (Consultado en línea: 20 de mayo de 2020).
Pérez-García F, Pérez-Tanoira R, Romanyk J, Arroyo T, Gómez-Herruz P, Cuadros-González J. Alltest rapid lateral flow immunoassays is reliable in diagnosing SARS-CoV-2 infection from 14 days after symptom onset: a prospective single-center study. J Clin Virol. 2020; 129: 104473. doi: https://10.1016/j.jcv.2020.104473. (Consultado en línea: 1 de junio de 2020).
Alcamí J, Coiras M, Diez F, Primo E, Bojo C, Pérez-Gómez B, et al. Informe técnico, anticuerpos neutralizantes frente a SARS-CoV-2. Madrid: Instituto de Salud Carlos III. 2020. Disponible en: https://www.conprueba.es/sites/default/files/informes/2020-07/anticuerpos neutralizantes frente a SARS-CoV-2.pdf.
Tamargo-Barbeito TO, Jiménez-Paneque RE, Hidalgo-Costa T, Mora-Díaz I, Peña-Casanovas A, Gutiérrez-Rojas AR. ¿Qué saber para optimizar el uso de medios diagnósticos en la clínica?. Rev Cubana Med. 2017;56(3):227-41. Disponible en: https://scielo.sld.cu/pdf/med/v56n3/med09317.pdf. (Consultado en línea: 1 de junio de 2020).
Organización Panamericana de la Salud/Organización Mundial de la Salud. Directrices de laboratorio para la detección y el diagnóstico de la infección con el virus COVID-19. Washington DC: OPS/OMS; 2020. Disponible en: https://www.paho.org/es/documentos/directrices-laboratorio-para-deteccion-diagnostico-infeccion-con-virus-covid-19.
World Health Organization. Advice on the use of point-of-care immunodiagnostic tests for COVID-19: scientific brief, 8 April 2020. Geneva: World Health Organization. 2020. Disponible en: https://www.who.int/news-room/commentaries/detail/advice-on-the-use-of-point-of-care-immunodiagnostic-tests-for-covid-19. (Consultado en línea: 1 de junio de 2020).