2020, Number 3
<< Back Next >>
Rev Cub Oftal 2020; 33 (3)
Development of intraocular lenses for phacoemulsification cataract surgery
Hernández RH, Hernández SJR, Ramos LM
Language: Spanish
References: 26
Page: 1-13
PDF size: 288.97 Kb.
ABSTRACT
Intraocular lens technology is in a process of permanent development, due to the increasing visual needs of patients undergoing cataract surgery. That is why we set out to do a search about the different lens models of lenses are offered, including the monofocal, bifocal, trifocal, toric trifocal and extended focus types. This new technology requires rigorous and accurate preoperative tests, so that surgical results respond to the concept of refractive crystalline lens surgery. We therefore conclude that future intraocular lens technology should be aimed at recovering functional vision. Each of the lens types has its own strengths and weaknesses, and so a universal solution does not exist. A report should be developed of advantages and disadvantages, so that work can be done on aspects requiring improvement, mainly the standardization of the improper focusing curve, the modulation transfer function and contrast sensitivity, as well as the implementation of actions to be performed jointly by patients, surgeons and manufacturers.
REFERENCES
Organización Mundial de la Salud. Prevention of blindness and visual impairment. OMS; 2011 [acceso: 05/01/2012]. Disponible en: http://www.who.int/blindness/
Auffarth G. Laboratory evaluation of the new CLAREON hydrophobic acrylic IOL material: biomaterial properties and capsular bag behavior. Portugal: Presentación en la Reunión Anual de la Sociedad Europea de Catarata y Cirugía Refractiva; 2017.
Werner L. Model eye and in vitro assessment of positive dysphotopsia or glare types photic phenomena: a comparison of a new material IOL to other monofocal intraocular lenses. Presentación en la Reunión Anual de la Sociedad Europea de Catarata y Cirugía Refractiva; 2017.
Mencucci R, Cennamo M, Venturi D, Vignapiano R, Favuzza E. Visual outcome, optical quality and patients' satisfaction with a new monofocal intraocular lens, enhanced for intermediate vision: preliminary results. J Cat Refract Surg. 2020;46(3):378-87.
Madrid-Costa D, Ruiz-Alcocer J, Ferrer-Blasco T, García LS, Montes-Mico R. Optical quality differences between three multifocal intraocular lenses: bifocal low add, bifocal moderate add and trifocal. J Refract Surg. 2013;29(11):749.
Pepose JS, Qazi MA, Davies J, Doane JF, Loden JC, Sivalingham V, et al. Visual performance of patients with bilateral vs. combination crystalens, ReZoom and ReSTOR - Intraocular lens implants. Am J Ophthalmol. 2007;144(3):347-57.
Knorz MC, Rincón JL, Suárez E, Alfonso JF, Fernández-Vega L, Titke C, et al. Subjective outcomes after bilateral implantation of an apodized diffractive +3,0 D multifocal ToricIOL in a prospective clinical study. J Refract Surg. 2013;29(11):762.
Lee S, Choi M, Xu ZW, Zhao ZY, Alexander E, Liu YA. Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens. Clin Ophthalmol. 2016;10:1031-8.
Law EM, Aggarwal RK, Kasaby H. Clinical outcomes with a new trifocal intraocular lens. Eur J Ophthalmol. 2014;24(4):501-8.
Weeber HA, Meijer ST, Piers PA. Extending the range of vision using diffractive intraocular lens technology. J Cat Refract Surg. 2015;41(12):2746-54.
Ferreira-Ríos I, Zúñiga-Posselt K, Serna-Ojeda JC, Chávez-Mondragón E. Objective and subjective results following implantation of the FineVision trifocal intraocular lens in Mexican patients. Int Ophthalmol. 2018;38(6):2617-22.
Carson D, Hill WE, Hong X, Karakelle M. Optical bench performance of AcrySof IQ ReSTOR, AT LISA tri, and FineVision intraocular lenses. Clin Ophthalmol. 2014;8:2105-13.
Pedrotti E, Bruni E, Bonacci E, Badalamenti R, Mastropasqua R, Marchini G. Comparative analysis of the clinical outcomes with a monofocal and an extended range of vision intraocular lens. J Refract Surg. 2016;32(7):436-42.
Domínguez-Vicent A, Esteve-Taboada JJ, Del Águila-Carrasco AJ, Ferrer Blasco T, Montes-Mico R. In vitro optical quality comparison between the Mini WELL Ready progressive multifocal and the TECNISSymfony. Graef Arch Clin Exper Ophthalmol. 2016;254(7):1387-97.
Támez Peña A, Nava García JA, Zaldívar Orta EL, Lozano Ramírez JF, Cadena Garza CL, Hernández Camarena JC, Valdez García JE. Efecto clínico de la rotación posoperatoria de los lentes intraoculares tóricos. Rev Mex Oftalmol. 2015;89(4):219-24. DOI: https://doi.org/10.1016/j.mexoft.2015.04.005
Castillo Cabrera J, Pucha Ortiz N, Pinos Velez E, Ipanque W, Chacón CL. Proposal for a tool for the calculation of toric intraocular lens using multivariate regression. Springer; 2019 [acceso: 18/08/2020]. Disponible en: https://link.springer.com/chapter/10.1007/978-3-030-32022-5_22
Esteve-Taboada J, Domínguez-Vicent A, Del Águila-Carrasco AJ, Ferrer-Blasco T, Montes-Mico R. Effect of large apertures on the optical quality of three multifocal lenses. J Refract Surg. 2015;31(10):666.
Clark KD. Toric intraocular lens outcomes with a new protocol for IOL selection and implant. J Fr Ophthalmol. 2018;41(2):145-51. DOI: https://doi.org/10.1016/j.jfo.2017.08.007
Hamdi IM. Subjective perception of Trifocal IOL performance, including Toricmodels. Clin Ophthalmol. 2019;13:1955-61.
Carreño E, Carreño EA, Carreño R, Carreño M, López V, Potvin R. Refractive and visual outcomes after bilateral implantation of a trifocal intraocular lens in a large population. Clin Ophthalmol. 2020;14:369-76.
Rementería-Capelo LA, García-Pérez JL, Contreras I, Blázquez V, Ruiz-Alcocer J. Automated refraction after trifocal and trifocal toric intraocular lens implantation. European Journal of Ophthalmology; 2020. DOI: https://journals.sagepub.com/doi/10.1177/1120672120914848
Albin R. Using ORA SYSTEM(r) technology with AnalyzOR(tm) technology to optimize refractive cataract outcomes: Normal to complex cases, simultaneous innovations. Alcon Medical Affairs; 2019 [acceso: 18/08/2020]. Disponible en: https://alconscience.com/wp-content/uploads/2019/06/
Cionni RJ. Modern preoperative intraocular lens calculation is better than intraoperative aberrometry for normal eyes Reply. J Cat Refr Surg. 2019;45(2):254.
Lipsky L, Barrett G. Comparison of toric intraocular lens alignment error with different toric markers. J Cat Refr Surg. 2019;45(11):1597-1601.
Ribeiro FJ, Ferreira TB, Relha C, Esteves C, Gaspar S. Predictability of different calculators in the minimization of postoperative astigmatism after implantation of a toric intraocular lens. Clin Ophthalmol. 2019;13:1649-56.
Jacob S. Nuevos lentes intraoculares. Franja ocular; 2018 [acceso: 18/08/2020]. Disponible en: https://www.franjaocular.com/index.php/catarata/782