Table 4: Diagnostic test evaluation for the diagnosis of transudate vs exudate by ultrasound. |
|||
|
Light’s criteria |
Total n (%) |
|
Transudate n (%) |
Exudate n (%) |
||
Ultrasound Transudate Exudate Total |
13 (81.2) 3 (18.7) 16 (100.0) |
2 (20.0) 8 (80.0) 10 (100.0) |
15 (57.7) 11 (42.3) 26 (100.0) |
Diagnostic test evaluation Sensitivity Specificity PPV NPV LR + LR - Accuracy |
81.25% 80.00% 86.66% 72.73% 4.06 0.23 80.77 |
||
PPV = positive predictive value. NPV = negative predictive value. LR = likelihood ratio. |