2020, Number 03
Infection risk factors after the permanent pacemaker implantation
Language: Spanish
References: 14
Page: 406-419
PDF size: 1148.51 Kb.
ABSTRACT
Introduction: The higher life expectancy in the general population has increased the prevalence of diseases of the heart conduction of electric system and, with it, the indication and implant of pacemaker.Objective: To identify the risk factors of infection after the permanent pacemaker implantation.
Methods: A cases and controls analytic study of 192 patients, to whom a permanent pacemaker was implanted between January, 2017 and December, 2019 was carried out in the Cardiology Service of Celia Sánchez Manduley Teaching Clinical Surgical Hospital from Granma. The study group was integrated by the 38 patients that presented infection after that procedure and every each patient of this group 2 were chosen that also received this device and had no infection that were part of the control group. The variables dependent on the patient, the device, the procedure and the exams were studied. The Fisher test and the chi-square test were used for qualitative variables, as corresponded and the Student t test for the quantitative variables. To determine the risk factors of infection a model of logistical regression was used.
Results: The male sex prevailed (60.5 %) and the mean age was of 76.1 years. As risk factors the use of antiagregants and anticoagulants, history of diabetes mellitus and glucemia figures higher than 8.0 mmol/L prevailed.
Conclusions: There are modifiable risk factors of infection, what constitutes a great challenge in medicine to influence on these factors to prevent lethal complications for life.
REFERENCES
Casola Crespo R, Casola Crespo E, Ramírez Lana LJ, Miranda Fragoso AE, Casola García SM, Casola Barreto EP. Alternativa de intervención en la infección de la bolsa del marcapaso permanente. AMC. 2016 [citado 29/10/2019];20(2):145–57. Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S1025-02552016000200007&lng=es
Femenía F, Arce M, Peñafort F, Arrieta M, Gutiérrez D. Complicaciones del implante de marcapaso definitivo: ¿Un evento operador dependiente? Análisis de 743 pacientes consecutivos. Arch Cardiol Méx. 2010 [citado 29/10/2019]; 80(2):95–9. Disponible en: http://www.scielo.org.mx/scielo.php?script=sci_arttext&pid=S1405-99402010000200006&lng=es
Silvestre García J, Aguado García JM, García Guerrero JJ. Infecciones en el sistema de marcapasos. Extracción de electrodos. Estimulación permanente por vía femoral. Rev Esp Cardiol Supl. 2007 [citado 29/10/2019];7(7):145–56. Disponible en: https://www.sciencedirect.com/science/article/abs/pii/S1131358707752664?via%3Dihub
Rosso F, Perafán Bautista PE, Carrillo Gómez DC, Ramos Amézquita MH, Cedano Rincón J. Infección relacionada con los dispositivos cardiovasculares. Rev Colombiana Cardiol. 2016 [citado 29/10/2019];23(6):508–13. Disponible en: https://www.elsevier.es/es-revista-revista-colombiana-cardiologia-203-articulo-infeccion-relacionada-con-dispositivos-cardiovasculares-S0120563316301383
Cueto López M de, Pozo León JL del, Álvarez de Luna FF, Marin Arriaza M. Diagnóstico microbiológico de las infecciones asociadas a dispositivos biomédicos. Enferm Infecc Microbiol Clin. 2016 [citado 21/10/2019]; 34(10):655–60. Disponible en: https://www.elsevier.es/es-revista-enfermedades-infecciosas-microbiologia-clinica-28-articulo-diagnostico-microbiologico-infecciones-asociadas-dispositivos-S0213005X15000877
Calderón Parra J, Sánchez Chica E, Asensio Vegas A, Fernández Lozano I, Toquero Ramos J, Castro Urda V, et al. Propuesta de una nueva calificación para determinar el riesgo de infección de dispositivos cardiacos implantables. Rev Española Cardiol. 2019 [citado 07/01/2020];72(10):806–12. Disponible en: https://www.revespcardiol.org/es-propuesta-una-nueva-calificacion-determinar-articulo-S0300893218304901
9 Argüello Hurtado M, Guevara Valdivia ME, Aranda Ayala ZL, Hernández Lara J. Factores asociados e implicados en la exteriorización de marcapasos definitivo, seguimiento a cinco años. Rev Med Inst Mex Seguro Soc. 2015 [citado 22/10/2019]; 53(Supl: 1):104–8. Disponible en: https://www.medigraphic.com/cgi-bin/new/resumen.cgi?IDARTICULO=62936
Fernández Hidalgo N. Prevención de las infecciones relacionadas con dispositivos intracardiacos. Hacia una racionalización de la práctica clínica. Rev Española Cardiol. 2019 [citado 07/01/2020];72(10):797–9. Disponible en: https://www.revespcardiol.org/es-prevencion-infecciones-relacionadas-con-dispositivos-articulo-S030089321930154X
Prutkin JM, Reynolds MR, Bao H, et al. Rates of and factors associated with infection in 200 909 Medicare implantable cardioverter-defibrillator implants: results from the National Cardiovascular Data Registry. Circulation. 2014 [citado 12/11/2019];130(13):1037–43. Disponible en: https://europepmc.org/article/med/25081281#impact
Hussein AA, Tarakji KG, Martin DO, Gadre A, Fraser T, Kim A, et al. Cardiac Implantable Electronic Device Infections Added Complexity and Suboptimal Out comes With Previously Abandoned Leads. JACC: clinical electrophysiology. 2017 [citado 12/11/2019];3(1):10–11. Disponible en: https://www.sciencedirect.com/science/article/pii/S2405500X16302535
Gutiérrez Carretero E, Arana Rueda E, Lomas Cabezas JM, Laviana Martínez F, Villa Gil–Ortega M, Acosta Martínez J, et al. Infecciones en dispositivos de estimulación cardiaca: diagnóstico y tratamiento en un centro de referencia. Rev Española Cardiol. 2017 [citado 12/11/2019];70(5):355–62. Disponible en: https://www.revespcardiol.org/es-infecciones-dispositivos-estimulacion-cardiaca-diagnostico-articulo-S0300893216304444?redirect=true