2004, Number s2
<< Back Next >>
Arch Cardiol Mex 2004; 74 (s2)
Rationale assessment of prosthetic heart valves dysfunction
Romero CA
Language: Spanish
References: 11
Page: 243-247
PDF size: 62.23 Kb.
ABSTRACT
The rationale evaluation of prosthetic valve disfunction begins when understanding that each model of prosthesis -produced in series- will work differently in each patient. It is certain that there are intrinsic factors in the manufacture of the prosthesis or its technical hemodynamic conditions, but the basic aspects of performance are unique in each certain patient. The morphologic and structural changes from each heart, as consequence of the valvular injuries displays individual variations that the surgeon has to solve, even thought they seems to have established patterns.
REFERENCES
Harken DE, Soroff HS, Taylor WJ, et al: Partial and complete prostheses in aortic insufficiency. J Thorac Cardiovasc Surg 1960; 40: 744-762.
Starr A, Edwards ML: Mitral replacement: clinical experience with a ball valve prosthesis. Ann Surg 1961; 154: 726.
Ross D, Jackson M, Davies J: The pulmonary autograft: a permanent aortic valve. Eur J Cardiothorac Surg 1992; 6: 113-116.
Vongpatanasin W, Hilis LD, Lange RA: Prosthetic heart valves. New Engl J Med 1996; 335: 407-16.
Jamieson WR, Burr LH, Anderson WN Jr, Chambers JB, Gams JP, Down CM; working group on Data Management of Society for Heart Valve Disease. Prosthesis-related complications: first-year annual rates. J Heart Valve Dis 2002; 6: 738-763.
Barbetseas J, Zoghbi WA: Evaluation of prosthetic valve function and associated complications. Cardiology Clinics 1998; 16: 505-30.
Romero Cárdenas A, Victoria Campos JL, Franco Zaragoza G, Roldán Gómez FJ, Espinola Zavaleta N, Vargas Barrón J: Diagnóstico Ecocardiográfico de la disfunción intermitente de prótesis de disco mitral. Arch Cardiol Mex 2001; 71: S3-80.
Romero Cárdenas A, Valdez O, Gutiérrez Fajardo P, Lamarche S, Espinola Zavaleta N, Rijlaarsdam M, Vargas Barrón J: Eco Doppler transtorácico y transesofágico en la detección de disfunción de prótesis mitral por insuficiencia. Arc Inst Cardiol Mex 1996; 66: 116-121.
Petraceck MR: Assessing options for the small aortic root. Heart Valve Dis 2002; 11 Suppl 1: S50-5.
Kaplan M, Kut MS, Demirtas MM, Cimen S, Ozler A: Prosthetic replacement of tricuspid valve: bioprosthetic or mechanical. Ann Thorac Surg 2002; 73: 467-73.
Crespo L, Espinola Zavaleta N, Romero Cárdenas A, Vargas Barrón J: La Ecocardiografía transesofágica en el estudio de las prótesis valvulares infectadas. Arch Inst Cardiol Mex 1998; 68: 315-321.