2019, Number 3
Pneumonia associated with artificial mechanical ventilation
Language: Spanish
References: 17
Page: 1-13
PDF size: 388.23 Kb.
ABSTRACT
Introduction: Pneumonia associated with artificial mechanical ventilation is considered one of the main causes of morbidity and mortality in the intensive care unit.Objective: To determine the clinical-epidemiological behavior of pneumonia associated with artificial mechanical ventilation in an intensive care unit.
Methods: An epidemiological, descriptive and longitudinal investigation was carried out with 168 patients carrying the disease, who were treated in the Intensive Care Unit at Doctor León Cuervo Rubio Provincial Surgical Teaching Hospital in Pinar del Río, from July 2017 to July 2018. The variables analyzed were age, sex, type of pneumonia, previous antibiotic therapy, germs and status at discharge. For the analysis of the variables, the absolute and relative frequencies (percentages) were used.
Results: Pneumonia associated with artificial mechanical ventilation prevailed in 90 females (53.57%) and in the age of 70 and over in 109 (64.88%). Late pneumonia was more frequent in 114 (67.86%) and the predominant risk factor was age over 65 years in 138 (82.14%). Pseudomonas aeruginosa was the most frequent germ isolated in the culture of respiratory secretions in 54 (32.14%). The majority of patients (110) were dead at discharge (65.48%).
Conclusions: In the intensive care unit, pneumonia associated with artificial mechanical ventilation is a disease with a high incidence and mortality in 70- year old female patients, and older.
REFERENCES
Rodríguez Álvarez L, Lamos Duarte A. Prevalencia y factores de riesgo de la neumonía asociada a la asistencia respiratoria mecánica en una unidad de cuidados intensivos adultos, Cúcuta, Colombia. Revista Investig Salud Univ Boyacá. 2017;4(2):248-66. Disponible en: https://doi.org/10.24267/23897325.256
Peñasco Y, Duerto J, González Castro A, Domínguez MJ, Rodríguez Borregán JC. Neumonía asociada a ventilación mecánica por Chryseo bacterium indologenes. Med Inten [Internet]. 2016 [citado: 20/01/2017];40(1):66-7. Disponible en: https://www.clinicalkey.es/service/content/pdf/watermarked/1-s2.0- S0210569115000236.pdf?locale=es
Durán Rodríguez R, Rubio Méndez AM, Cobas Sánchez A, Rodríguez Paján N, Castillo Pérez Y. Comportamiento de neumonía asociada a ventilación mecánica en cuidados intensivos de adultos. Rev. Inf. Cient. 2017 [citado: 28/09/2018];96(4):[aprox. 10 p.]. Disponible en: http://www.revinfcientifica.sld.cu/index.php/ric/article/view/1182
Centro Nacional de Excelencia Tecnológica en Salud. Prevención, diagnóstico y tratamiento de la neumonía asociada a ventilación mecánica. México: Secretaría de Salud; 2013 [citado: 07/02/2017]. Disponible en: http://www.cenetec.salud.gob.mx/descargas/gpc/CatalogoMaestro/IMSS_624_13_NEUM_VENTIL_MECANICA/624GER.pdf
Delgado-Fernández R I, Hernández-Ruiz A, Yanes-Oviedo C, Puig-Miranda J, Bandera- Ramírez M, Sánchez-Govea M. Factores de riesgo de neumonía nosocomial en pacientes con ictus ingresados en una terapia polivalente. Revista Cubana de Medicina Intensiva y Emergencias. 2018 [citado: 12/1/2018];17(2). Disponible en: http://www.revmie.sld.cu/index.php/mie/article/view/320Delgado
León Chahua C, Oscanoa Espinoza T, Chávez Gutiérrez C, Chávez Gutiérrez J. Características epidemiológicas de la neumonía intrahospitalaria en un servicio de medicina interna del Hospital Guillermo Almenara Irigoyen de Lima, Perú. Horiz. Med. 2016 Jul [citado: 21/05/2019];16(3):43-9. Disponible en: http://www.scielo.org.pe/scielo.php?script=sci_arttext&pid=S1727-558X2016000300007&lng=es
Rebellón Sánchez D, Parra Morales T, Quintero Guerrero K, Méndez Fandiño R. Perspectiva sobre el perfil microbiológico de las neumonías asociadas a ventilación mecánica en hospitales de alta complejidad en Latinoamérica. Horiz. Med. 2015 Abr [citado: 30/09/2019];15(2):56-65. Disponible en: http://www.scielo.org.pe/scielo.php?script=sci_arttext&pid=S1727-558X2015000200009&lng=es.
Gómez Carcassés L, Pérez Hernández L, Pujol Enseñat Y, Piña Loyola Carmen. Caracterización de pacientes con neumonía por Acinetobacter baumannii asociada a la ventilación mecánica en las Unidades de Cuidados Progresivos. Medisur. 2016 Ago [citado: 30/09/2019];14(4):389-403. Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S1727-897X2016000400007&lng=es