Recent developments in oxygen monitoring
Barker SJ
Language: English
References: 21
Page: 65-69
PDF size: 63.04 Kb.
Text Extraction
In this lecture we review recent advances in the monitoring of patient oxygenation. The transport of oxygen from the atmosphere to the mitochondrion will be discussed, and monitors that function at each of four stages of the transport process will be described. These four stages include respired gas, arterial blood, tissue, and venous blood. Respired gas monitors will be mentioned only briefly. Recent developments in pulse oximetry will be reviewed in detail. Continuous intraarterial blood-gas sensors will be contrasted with other arterial oxygen monitors. We will also cover tissue oxygen monitoring and mixed-venous oximetry.
REFERENCES
Barker SJ, Tremper KK, Hyatt J, Heitzmann H. Comparison of three oxygen monitors in detecting endobronchial intubation. J Clin Monitoring 1988;4:240-43.
Barker SJ, Tremper KK. The effect of carbon monoxide inhalation on pulse oximetry and transcutaneous PO2. Anesthesiology 1987;66:677-79.
Barker SJ, et al. Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry. Anesthesiology 1989;70:112-17.
Sidi A, Rush WR, Paulus DA, et al. Effect of fluorescein, indocyanine green, and methylene blue on the measurement of oxygen saturation by pulse oximetry. Anesthesiology 1986;65(3A):A132.
Scheller MS, Unger RJ, Kelner MJ. Effects of intravenously administered dyes on pulse oximetry readings. Anesthesiology 1986;65:550-52.
Lawson D, Norley I, Korbon G, Loeb R, Ellis J. Blood flow limits and pulse oximeter signal detection. Anesthesiology 1987;67:599-603.
Narang VPS. Utility of the pulse oximeter during cardiopulmonary resuscitation. Anesthesiology 1986;65:239-40.
Eisele JH, Downs D. Ambient light affects pulse oximeters. Anesthesiology 1987;67:864-65.
Barker SJ. Motion-Resistant pulse oximetry: A comparison of new and old models. Anesth Analg 2002;95:967-72.
Bohnhorst B, Peter C, Poets CF. Pulse oximeters’ reliability in detecting hypoxia and bradycardia: Comparison between a conventional and two new generation oximeters. Crit Care Med 2000;28(5):1565-1568.
Durbin CG, Rostow SK. More reliable oximetry reduces the frequency of arterial blood gas analyses and hastens weaning after cardiac surgery: A prospective, randomized trial of the clinical impact of a new technology. Crit Care Med 2002;30:1735-1740.
Kim JM, Arakawa K, Benson KT, et al. Pulse oximetry and circulatory kinetics associated with pulse volume amplitude measured by photoelectric plethysmography. Anesth Analg 1986;65:133-39.
Barker SJ, Hyatt J, Shah NK, Kao YJ. The effect of sensor malpositioning on pulse oximeter accuracy during hypoxemia. Anesthesiology 1993;79:248-54.
Rithalia SVS, Bennett PJ, Tinker J. The performance characteristics of an intraarterial oxygen electrode. Intensive Care Med 1981;7:305-7.
Lubbers DW, Opitz N. Die pCO2/pO2-optode: eine neue pCO2 bzw. pO2-Messonde zur Messung des pCO2 oder PO2 von Gasen and Flussigkeiten. Z Naturforsch 1975;30:532-33.
Barker SJ, Tremper KK, Hyatt J, et al. Continuous fiberoptic arterial oxygen tension measurements in dogs. J Clin Monitoring 1987;39(1):48-52.
Barker SJ, Tremper KK, Heitzmann HA, et al. A clinical study of fiberoptic arterial oxygen tension. Crit Care Med 1987;15:403-8.
Barker SJ, Hyatt J. Continuous measurement of intraarterial pHa, PaCO2 and PaO2 in the operating room. Anesth Analg 1991;73:43-48.
Tremper KK, Waxman K, Shoemaker WC. Effects of hypoxia and shock on transcutaneous PO2 values in dogs. Crit Care Med 1979;7:526-31.
Row MI, Weinberg G. Transcutaneous oxygen monitoring in shock and resuscitation. J Pediatr Surg 1979;17:773-78.
Gettinger A, DeTraglia MC, Glass DD. In vivo comparison of two mixed venous saturation catheters. Anesthesiology 1987;66(3): 373-75.