2016, Number 4
<< Back Next >>
Rev Cub Oftal 2016; 29 (4)
Keratometries taken with Pentacam and Maloney method in patients with cataract and previous corneal refractive surgery
Pérez CE, Cárdenas DT, Ojeda GA, Rodríguez SB, Veitía RZA, Méndez DEA
Language: Spanish
References: 29
Page: 632-644
PDF size: 107.33 Kb.
ABSTRACT
Objective: to compare the keratometries with Pentacam and with Maloney method in
patients with cataract, who had previously undergone refractive corneal surgery.
Methods: comparative, prospective, descriptive and longitudinal study of
keratometric values estimated with Pentacam camera and with Maloney's method in
patients with cataract and previous corneal refractive surgery. Forty one eyes were
distributed into two groups; twenty three were studied by Maloney method and 18 by
Pentacam. Database information was processed by was processed by version 11.0
SPSS software for Windows. The confidence interval was 95% and the error margin
below 0.05 %.
Results: myopic astigmatism (simple or compound) prevailed and it was found in
14 eyes (60.9 %) of Group 1 and in 16 eyes (89 %) of group 2. Most of the studied
eyes (37) had radiated keratotomy and just 4.3 in group 1 and one in group 2 had
myopic LASEK. The average keratometry with Maloney's method was 37.55 D
whereas the average value provided by the Pentacam (EKR at 4,0 mm) was 39.18 D,
with a significant average difference of 1.64 D (p= 0.019).
Conclusions: the keratometric values estimated by Maloney's method and the EKR at
4,0 mm from the Holladay Report of Pentacam show significant differences in patients
with previous radiated keratotomy.
REFERENCES
Prado SA, Nava NG. Cálculo del poder dióptrico de lentes intraoculares ¿Cómo evitar la sorpresa refractiva? Rev Mex Oftalmol. 2009;83(5):272-80.
Prado SA, Camas BJ, Sosa LS, Nava HN. Cómo evitar la sorpresa refractiva. Cálculo del poder dióptrico de lentes intraoculares en casos especiales. Rev Mex Oftalmol. 2010;84(1):39-48.
Pakoslawski F, Ghilino O, Marotta H, Estavillo M, Argibay MC. Cálculo de lente intraocular luego de cirugía refractiva miópica: nuestro método. Resultados Preliminares. Buenos Aires: Arca Oftalmol. 2009;80(3):91-4.
Urrutia Breton IP, Matiz Moreno H, Morales Gómez ME. Resultados refractivos en pacientes operados de catarata con antecedente de cirugía refractiva corneal. Rev Mex Oftalmol. 2006;80(6):312-7.
Latkany R, Chokshi A, Speader M, Abramson I, Solowitz B. Intraocular lens calculations after refractive surgery. J Cataract Refract Surgery. 2005;31(3):562-70.
Ortega JJ. Cálculo del lente Intraocular después de cirugía refractiva. En: Centurión V, editor. El Libro del Cristalino de las Américas. Brasil: Livraria Santos; 2007. p. 119-22.
Mesa JC, Martí T, Arruga J. Cálculo de la potencia de la lente intraocular en situaciones especiales. Ann d'Oftalmologia. 2008;16(2):68-89.
Mesa JC, Amías V, Cabiró I , Cotanda P, Porta J, Rodríguez F, et al. Algoritmo de corrección de la queratometría tras cirugía refractiva corneal. Ann d'Oftalmología. 2009;17(3):137-43.
Aramberri J. Cálculo de la lente intraocular tras cirugía refractiva corneal. En: Alió J, Rodríguez-Prats J, editor. Buscando la excelencia en la cirugía de la catarata. Barcelona: Editorial Glosa; 2006. p. 179-91.
Borasio E, Stevens E, Smith GT. Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula. J Cataract Refract Surg. 2006;32(12):2004-14.
Masket S, Masket SE. Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excímer laser photoablation. J Cataract Refract Surg. 2006;32(3):430-4.
Gimbel H, Sun R, Kaye GB. Refractive error in cataract surgery after previous refractive surgery. J Cataract Refract Surg. 2000;26(1):142-4.
Wang L, Booth M, Koch D. Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK. Ophthalmology. 2004;111(10):1825-31.
Jain R, Dilraj G, Grewal SPS. Repeatability of corneal parameters with Pentacam after laser in situ keratomileusis. Indian J Ophthalmol. 2007;55(5):341-7.
Konstantopoulos A, Hossain P, Anderson DF. Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis? Br J Ophthalmol. 2007;91(4):551-7.
Savini G, Hoffer KJ, Zanini M. IOL Power calculations after LASIK and PRK. Catar Refract Surg Tod Eur. 2007 [citado 10 de noviembre de 2011]. Disponible en: http://bmctoday.net/crstodayeurope/2007/04/
Savini G, Barboni P, Zanini M. Intraocular lens power calculation after myopic refractive surgery: theoretical comparison of different methods. Ophthalmology. 2006;113(8):1271-82.
Mesa J, Rouras A, Cabiró I, Amías V, Porta J, Solanas L. Intraocular lens power calculation after myopic excímer laser surgery with no previous data. J Emmetropia; 2011;2(2):97-102.
Cárdenas T, Ravelo W, Capote A, Pérez EC, Cuan Y, Hernández I. Poder corneal poscirugía fotoablativa en miopes. Sistema Scheimpflug topógrafo Pentacam vs. método de Maloney. Rev Cubana Oftalmol. 2014 [citado 8 de octubre de 2016];27(1). Disponible en: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/229/html
Cárdenas T, Vinardell S, Capote A, Pérez EC, Cuan Y, Cruz D. Estudio queratométrico por topógrafo Pentacam en hipermétropes con cirugía láser vs. método de Maloney. Rev Cubana Oftalmol. 2014 [citado 8 de octubre de 2016]. Disponible en: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/230/html
Duane's Ophthalmology [CD-ROM]. Version 2.0. New York: Multimedia; 2002.
López HJ, López VM, Otero PA, Belmonte UM, López VJ, Montoro DJ. Repercusión de la intervención de cataratas en la capacidad funcional del anciano. Arch Soc Esp Oftalmol. 2005 [citado 20 de septiembre de 2009];79(5). Disponible en: http://www.scielo.isciii.es/scielo.php
Arce GC, López Moreno G. Cálculo del lente intraocular después de cirugía refractiva. Rev Col Oftalmol. 2007;40(1):205-46.
Pérez EC, Cuan Y, Cárdenas T, Méndez AM, Rodríguez B. Aplicación del método de Maloney en el cálculo del lente intraocular después de cirugía refractiva corneal. Rev Cubana Oftalmol. 2010;23(Supl. 1):470-9.
Cuan Aguilar Y, Pérez Candelaria E, Montero Díaz E, Santiesteban García I, Ortega Díaz L, Cárdenas Díaz T. Utilidad del Pentacam para medir el poder corneal después de cirugía refractiva con excímer láser. Rev Cubana Oftalmol. 2010;23(Supl. 1):513-21.
Savini G, Barboni P, Profazio V, Zanini M, Hoffer KJ. Corneal power measurements with the pentacam scheimpflug camera after myopic excimer laser surgery. J Cataract Refract Surg. 2008;34(4):809-13.
Viteri E. Uso del topógrafo Pentacam para calcular el poder de la LIO. High Lights Ohthalmol. 2008 [citado 20 de junio de 2013];36(3). Disponible en: http://www.omnisrl.com.ar/descargas/uso_del_topógrafo Pentacam_por_calcular_el_poder_del_lio_viteri_spanish.pdf
Mesa J, Marti T, Arruga J. Cálculo del poder dióptrico de la lente intraocular tras cirugía refractiva. Arch Soc Esp Oftalmol. 2005 [citado 13 de diciembre de 2011];80(12):699-703. Disponible en: http://scielo.isciii.es/scielo.php?pid=S0365- 66912005001200004&script=sci_arttext&tlng=es
Mesa JC, Porta J, Cbiró I, Amías V, Rouras A. Cálculo biométrico tras cirugía refractiva. Superficie ocular. Rev Laborat Thea. 2010;37(3):747-8.