2016, Number 2
<< Back Next >>
Rev Cub Oftal 2016; 29 (2)
Fundamental methods for calculation of intraocular lens after corneal refractive surgery
Cárdenas DT, Hernández LI, Guerra AM, Cruz ID, Cuan AY, Pérez CE
Language: Spanish
References: 62
Page: 271-284
PDF size: 142.95 Kb.
ABSTRACT
With the emergence and development of the corneal refractive surgery, the refractive
defects of millions of patients have been surgically corrected. As time goes by, the physiological opacification of the crystalline lens begins, thus reducing the visual
acuity of those patients whose corneal curvature has been modified. Should the
crystalline lens be modified and should the intraocular lens power be adequately
calculated to achieve emetropia, ophthalmology faces then a new challenge. The
intraocular lens calculation in patients with corneal refractive surgery is much more
complex since, in addition to extreme axial lengths, there are factors derived from the
previous surgery that alter predictability of the visual result, with the use of existing
intraocular lens calculation formulae. Several methods have been so far described,
which allow correctly determining the lens power to be implanted, depending on
available data. This was the main reason for making a review of different publications
to describe the main methods for intraocular lens calculation in these patients.
Infomed platform, mainly the virtual library of health, was used with all its searchers.
REFERENCES
Savini G, Barboni P, Zanini M. Correlation between attempted correction and keratometric refractive index of the cornea after myopic excímer laser surgery. J Refract Surg. 2007;23(5):461-6.
Alió JL. Laser refractive surgery: have we arrived? Br J Ophthalmol. 2012;96(9):1159.
Winkler C, Khoramnia R, Salgado J, Wullner C. First clinical results with a new 200 kHz femtosecond laser system. Br J Ophthalmol. 2012;96(9):788-92.
Reynolds MJ, Naroo SA, Moore T, Shah S. Excímer láser surface ablation - a review. Clin Experim Ophthalmol. 2010;38(2):168-82.
Reinstein DZ, Threlfall WB, Cook R, Cremonesi E, Sutton H, Archer T. Short term LASIK outcomes using the Technolas 217C excímer laser and Hansatome microkeratome in 46 708 eyes treated between 1998 and 2001. Br J Ophthalmol. 2012;96(9):1173-9.
Del Monte DW. Anatomy and physiology of the cornea. J Cataract Refract Surg. 2011;37(3):588-98.
Kawamorita T, Uozato H, Kamiya K, Leon Bax, Tsutsui K, Aizawa D, Shimizu K. Repeatability, reproducibility and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement. J Cataract Refract Surg. 2009;35(1):127-33.
Rosa N. Corneal morphological changes after myopic excimer laser refractive surgery. Cornea. 2011;30(2):130-5.
Rosa N. Analysis of photoastigmatic keratectomy with the cross-cylinder ablation. Ind J Ophthalmol. 2012;60(4):283-7.
Pérez EC. Métodos para determinar el poder de la lente intraocular después de cirugía refractiva corneal. Rev Cubana Oftalmol. 2013 [citado 12 de diciembre de 2013]. Disponible en: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/178/html
Rosa N, de Bernardo M, Lanza M. Axial eye length evaluation before and after hyperopic photorefractive keratectomy. J Refract Surg. 2013;29(80):200.
De Bernardo M, Rosa N. Diehl-Miller nomogram for intraocular lens power calculation. J Cat Refract Surg. 2013;39(11):1791.
Wang L, Shirayama M, Ma XJ, Kohnen T, Koch DD. Optimizing intraocular lens power calculations in eyes with axial lengths above 25,0 mm. J Cataract Refract Surg. 2011;37(11):2018-27.
Mesa JC, Martí T, Arruga J. Cálculo de la potencia de la lente intraocular en situaciones especiales. Ann Oftalmol. 2008;16(2):68-89.
Rosa N, Capaso L, Romano A. A new method of calculating intraocular lens power after photorefractive keratectomy. J Cataract Refract Surg. 2002;18(6):720-4.
Borasio E, Stevens E, Smith GT. Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula. J Cat Refract Surg. 2006;32(12):2004-14.
Masket S, Masket SE. Simple regressión formula for intraocular lens power adjustment in eyes requiring cataract surgery after excímer laser photoablation. J Cataract Refract Surg. 2006;32(3):430-4.
De Bernardo M, Capasso L, Rosa N. Algorithm for the estimation of the corneal power in eyes with previous myopic laser refractive surgery. Cornea. 2014;33(6):5.
Rosa N, Capasso L, de Bernardo M, Lanza M. IOL power calculation after refractive surgery. Ophthalmology. 2011;118(11):2309-11.
Rosa N. Intraocular lens power calculation: a challenging case. Optometry & Vision Science. 2014;91:29-31.
Rosa N. Reliability of the IOLMaster in measuring corneal power changes after hyperopic photorefractive keratectomy. J Refract Surg. 2011;27(4):293-98.
Konstantopoulos A, Hossain P, Anderson DF. Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis? Br J Ophthalmol. 2007;91(4):551-7.
Ortega L. Modificaciones de la curvatura posterior corneal después de la cirugía refractiva láser. Rev Cubana Oftalmol. 2011;24(1):111-23.
Mesa JC, Porta J, Cbiró I, Amías V, Rouras A. Cálculo biométrico tras cirugía refractiva. Superficie ocular. Rev Laborat Thea. 2010;37(3):747-8.
Mesa JC, Ruiz CL. El cálculo de la lente intraocular tras cirugía foto-refractiva corneal. Revisión de la literatura. Arch Soc Esp Oftalmol. 2009;84(6):283-92.
Ortega JG, Freidell H, Kwitko S, Lu LW, Zacharias W, Sáchez JC. Cuál es la técnica de elección para el cálculo del LIO post-cirugía refractiva. Noticiero ALACCSAR/ Diciembre 2011 [citado 10 enero 2012]. Disponible en: http://www.alaccsa.com/noticiero_diciembre_11.htm
Aramberri J. Intraocular lens power calculation after corneal refractive surgery: double-K method. J Cataract Refract Surg. 2003;29(11):2063-8.
Prado A, Cama JT, Sosa SP, Nava NG. Cómo evitar la sorpresa refractiva. Cálculo del poder dióptrico de lentes intraoculares en casos especiales. Rev Mex Oftalmol. 2010;84(1):39-48.
Cuan Y, Pérez E, Montero E, Santiesteban I, Ortega L, Cárdenas T. Utilidad del Topógrafo Pentacam para medir el poder corneal después de cirugía refractiva con excímer láser. Rev Cubana Oftalmol. 2010;23(Sup. 1):513-21.
Cárdenas T, Torres R, Corcho Y, Capote A, Cuan Y, Hernández I. Sistema Scheimpflug Topógrafo Pentacam vs. método de la historia clínica en hipermétropes con cirugía refractiva previa. Rev Cubana Oftalmol. 2013 [citado junio 2013];26(1). Disponible en: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/173
Saiki M. Modified double-K method for intraocular lens power calculation after excimer laser corneal refractive surgery. J Cataract Refract Surg. 2013;39(4):556-62.
Aramberri J. Cálculo de la lente intraocular tras cirugía refractiva corneal. En: Alió J, Rodríguez-Prats J. Buscando la excelencia en la cirugía de la catarata. Barcelona, Editorial Glosa; 2006. p. 179-91.
Koch D, Wang L. Calculating IOL power in eyes that have had refractive surgery. J Cataract Refract Surgery. 2003;29(11):2039-42.
Hamed A, Wang L, Misra M, Koch C. A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis. Ophthalmology. 2002;109(4):651-8.
Savini G, Barboni P, Profazio V, Zanini M, Hoffer KJ. Corneal power measurements with the Topógrafo Pentacam Scheimpflug camera after myopic excímer laser surgery. J Cataract Refract Surg. 2008;34(5):809-13.
Jiménez G. Cálculo de lente intraocular en pacientes con cirugía refractiva previa. Rev Mex Oftalmol. 2007;81(3):134-7.
Domínguez M. Beneficios del sistema Scheimpflug en glaucoma. Rev Cubana Oftalmol. 2012 [citado 7 de noviembre de 2014]. Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864- 21762012000300011&lng=es&nrm=iso&tlng=es
Miranda I. Comparación de los valores del espesor corneal central según los equipos Lenstar, Galilei y Pentacam. Rev Cubana Oftalmol. 2012;25(1):65-71.
Hernández I. Cuantificación objetiva de la opacidad de la cápsula posterior mediante tomogramas Scheimpflug del Pentacam. Rev Cubana Oftalmol. 2011;24(2):208-19.
Tirado OM, Hernández A. Topógrafos de elevación en el diagnóstico del queratocono. Rev Cubana Oftalmol. 2011;24(2):364-73.
Shammas HJ, Hoffer KJ, Shammas MC. Scheimpflug photography keratometry readings for routine intraocular lens power calculation. J Cataract Refract Surg. 2009;35(2):330-4.
Cárdenas T, Ravelo W, Capote A, Pérez EC, Cuan Y, Hernández I. Poder corneal poscirugía fotoablativa en miopes. Sistema Scheimpflug Topógrafo Pentacam vs. Método de Maloney. Rev Cubana Oftalmol. 2014 [citado marzo 2014];27(1). Disponible en: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/229/html
Cárdenas T, Vinardell S, Capote A, Pérez EC, Cuan Y, Cruz D. Estudio queratométrico por Topógrafo Pentacam en hipermetrópes con cirugía láser vs. Método de Maloney. Rev Cubana Oftalmol. 2014 [citado marzo 2014];27(1). Disponible en: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/230/html
Speicher C, Seitz J. Cataract surgery in patients with prior refractive surgery. Curr opin Ophthalmol. 2003;14(1):44-53.
Feiz V, Moshirfar M, Mannis M, Reilly C, Garcia-Ferrer F. Nomogram-based intraocular lens power adjustment after myopic photokeratectomy and Lasik. Ophtahlmology. 2005;112(8):1381-7.
Saiki M. A new central-peripheral corneal curvature method for intraocular lens power calculation after excimer laser refractive surgery. Act Ophthalmol. 2013;91(2):e133-9.
Shammas H, Shamas M, Garabet A, Kim J, Shammas A, LaBree L. Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. Am J Ophthalmol. 2003;136(3):426-32.
Jarade EF, Abinader FC, Tabbara KF. Intraocular lens power calculation following LASIK. Invest ophthalmol vis sci. 2002;43:41-3.
Latkany R, Chokshi A, Speader M, Abramson I, Solowitz B. Intraocular lens calculations after refractive surgery. J Cat Refrac Surg. 2005;31(3):562-70.
Camellin M, Calossi A. A new formula for intraocular lens power calculation after refractive corneal surgery. J Refract Surg. 2006;22(2):187-99.
Haigis W. Corneal power alter refractive surgery for myopa: contact lens method. J Cataract Refract Surgery 2003;29(7):1397-411.
Koch DD, Liu JF, Hyde LL, Rock RL, Emery JM. Refractive complications of cataract surgery after radial keratotomy. Am J Ophthalmol. 1989;108(6):676-82.
Pérez EC, Aguilar Y, Cárdenas T, Menéndez AM, Rodríguez B. Aplicación del método de Maloney en el cálculo de la lente intraocular después de cirugía refractiva corneal. Rev Cubana Oftalmol. 2010;23(Suppl.1):470-9.
Ferrara G, Cennamo G, Marotta G. New formula to calculate IOL power. J Cataract Refract Surg. 2004;20(5):465-71.
Mackool RJ, Wilson K, Mackool R. Intraocular lens power calculation after laser in situ keratomieleusis: apahakic refraction technique. J Cataract Refract Surg. 2006;32(3):435-7.
Ianchulev T, Salz J, Hoffer K, Albini T, Hsu H, Labree L. Intraoperatory optical biometry for intraocular lens power estimation without axial length and keratometry measurements. J Cataract Refract Surg. 2005;31(8):1530-6.
Ianchulev T. Intraoperative refractive biometry for predicting intraocular lens power calculation after prior myopic refractive surgery. Ophthalmology. 2014;121(1):56-60.
Savini G, Bedei A, Barboni P, Ducoli P, Hoffer KJ. Intraocular lens power calculation by Ray-Tracing after myopic excimer laser surgery. Am J Ophthalmol. 2014;157(1):150-3.
Hoffmann P, Wahl J, Preussner PR. Accuracy of intraocular lens calculation with ray tracing. J Refract Surg. 2012;28(9):650-5.
Minami K. Ray-tracing intraocular lens power calculation using anterior segment optical coherence tomography measurements. J Cataract Refract Surg. 2012;38(10):1758-63.
Savini G, Calossi A, Camellin M, Carones F, Fantozzi M, Hoffer KJ. Corneal ray tracing versus simulated keratometry for estimating corneal power changes after excimer laser surgery. J Cataract Refract Surg. 2014;40(7):1109-15.
Saiki M. Ray tracing software for intraocular lens power calculation after corneal excímer laser surgery. Jpn J Ophthalmol. 2014;58(3):276-81.