2016, Number 1
<< Back Next >>
Rev cubana med 2016; 55 (1)
Influence of gauge needles on the effectiveness of the hemodialysis
Villatoro VJF, Rojas EJJ, Herrera VM, Semanat VD, Torres MR, Sat AF
Language: Spanish
References: 17
Page: 20-29
PDF size: 95.92 Kb.
ABSTRACT
Introduction: dialysis efficiency influences the survival of patients.
Objective: determine the effect of modifying the gauge needle puncture of
arteriovenous fistula on dialysis effectiveness.
Methods: an experimental study was conducted from March, 2011 to March, 2012
at Hermanos Ameijeiras Clinical and Surgical Hospital in Havana. The universe is
composed of hemodialysis patients with arteriovenous fistula, and the effect of
modifying the gauge needle puncture 16G and 15G was determined on the efficacy
of dialysis.
Results: There were no significant differences in the efficacy of conventional
hemodialysis, according to the method of calculation of Kt/V monocompartimental
and the percentage reduction of urea.
Conclusions: changing the size of the needle puncture does not affect the
effectiveness of conventional hemodialysis.
REFERENCES
Miranda V. Cuidados de las fístulas arteriovenosas. Intervenciones y actividades del profesional de enfermería. Dial Traspl. 2010;31(1):12-6.
Gallego E, Portolés JM, Llamas F, Serrano A, Tallón S, Andrés E, et al. Efecto del calibre de las agujas sobre la recirculación y la eficacia de la HD. Nefrología. 1997;16:322.
Martínez O, Rodríguez J, Ruiz B, Martín JA, Mérida E. Catéter-fístula: una nueva alternativa en la punción de accesos vasculares. Rev Soc Esp Enferm Nefrol. 2010;13(2):105-11.
Pastor A, Balaguer R, Pastor M. Una alternativa a la aguja de hemodiálisis. Libro de Comunicaciones del XXVI Congreso de la SEDEN. Zaragoza, 2001. p. 85-91.
Rodríguez JA, González E, Gutiérrez JM. Guía de acceso vascular para hemodiálisis. Nefrología. 2005;25(Supl 1):3-97.
Port FK, Ashby VB, Dhingra RK, Roys EC, Wolfe RA. Dialysis dose and body mass index are strongly associated with survival in hemodialysis patients. J Am Soc Nephrol. 2002;13:1061-6.
European Best Practice Guidelines for Haemodialysis. Nephrol Dial Transplant. 2002;17(Supl 7):17-21.
National Kidney Foundation. KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: Hemodialysis Adequacy, Peritoneal Dialysis Adequacy and Vascular Access. Am J Kidney Dis. 2006;48(Suppl 1):S1- S322.
Besarab A. Access monitoring is worthwhile and valuable. Blood Purif. 2006;24:77-89.
Roy-Chaudhury P, Arend L, Zhang J, Krishnamoorthy M, Wang Y, Banerjee R, et al. Neointimal hyperplasia in early arteriovenous fistula failure. Am J Kidney Dis. 2007;50:782-90.
Jarriz A, Bardales E, Pulido A, Albalate M. Efecto del calibre de la aguja sobre la eficacia de la hemodiálisis. Rev Soc Esp Enferm Nefrol. 2006;9(2):128-31.
Alcaraz F, Abril D, Granados I, Mañé N, Real J, Yuste E, et al. Una actuación de enfermería: intentar aliviar el dolor en las punciones de hemodiálisis. Rev Soc Esp Enferm Nefrol. 2005;8(3):231-6.
Fernández R, Cañadas GA, Fernández R, Cañadas GR. Efecto de la posición del bisel de la aguja en el acceso a la fístula arteriovenosa interna. Rev Soc Esp Enferm Nefrol. 2008;11(4):254-8.
Wizemann V, Wabel P, Chamney P, Zaluska W, Moissl U, Rode C, et al. The mortality risk of overhydration in haemodialysis patients. Nephrol Dial Transplant. 2009;24(5):1574-9.
Goodkin DA, Bragg-Gresham JL, Koenig KG, Wolfe RA, Akiba T, Andreucci VE, et al. Association of comorbid conditions and mortality in hemodialysis patients in Europe, Japan, and the United States: the Dialysis Outcomes and Practice Patterns Study (DOPPS). J Am Soc Nephrol. 2003;14(12):3270-7.
Górriz JL, Otero A. Impacto socio sanitario de la enfermedad renal crónica avanzada. Nefrología. 2008(Supl 3):7-15.
Maduell F. Dosis de hemodiálisis: condición sine qua non de diálisis adecuada. Nefrologia. 1999;19(Supl 4):51-3.