ABSTRACT
Distal radius fractures are very common in medical
practice. In our service, we may not have the most
widely used devices for fixation of these fractures at
a given moment. For this reason, we must consider
all possible combinations within our power to correct
them since most of the time, it is impossible to
maintain a fracture reduction using a single
technique. We present the case of a 24-year-old
female patient treated at the "Dr. Gustavo Aldereguía
Lima" University General Hospital in Cienfuegos due
to a displaced fracture of the left distal radius
caused by impaction. It was successfully stabilized
by internal fixation with plates, screws and the
RALCA
® external mini-fixator.
REFERENCES
Fernández DL. Fracture of the distal radius: operative treatment. Instr Course Lect. 1993 ; 42: 73-88.
Truffin Rodríguez Y, Gámez Arregoitía R, Gómez Gil l, Requeiro Morejón J. Fijación externa de la fracturas inestables del extremo distal del radio. Presentación de un caso. Medisur [revista en Internet]. 2014 [ cited 9 Ene 2015 ] ; 12 (6): [aprox. 7p]. Available from: http://scielo.sld.cu/scielo.php?script=sci_arttext& pid=S1727-897X2014000600011.
Rahman O, Khan MQ, Rasheed MA, Ahmad S. Treatment of unstable intraarticular fracture of disal radius: POP casting with external fixation. J Pak Med Assoc. 2012 ; 62 (4): 358-62.
Elizondo Elizondo H, Cárdenas Estrada E, Mendoza Mendoza J, Vilchez Cavazos F, Mendoza Lemus O, Acostal-Olivo C. Evaluación del paciente con fractura de radio distal tratado con fijación percútanea. Acta Ortopédica Mexicana. 2010 ; 24 (5): 312-6.
Geller L, Bernstein M, Carli A, Berry G, Reindl R, Harvey E. Efficacy of different fixation devices in maintaining an initial reduction for surgically managed distal radius factures. Can J Surg. 2009 ; 52 (5): E161-6.
Schuind F, El Kazzi W, Cermak K, Donkerwolcke M, Burny F. External fixation at the wrist and hand. Rev Med Brux. 2011 ; 32 Suppl 6: SS71-5.
Richard MJ, Wartinbee D, Riboh J, Miller M, Leversedge F, Ruch D. Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius. J Hand Surg Am. 2011 ; 36 (10): 1614-20.
Othman AY. Fixation of dorsally displaced distal radius fractures with volar plate. J Trauma. 2009 ; 66 (5): 1416-20.
Lee SK, Seo DW, Kim KJ, Yang D, Choy WS. Volar long locking compression plate fixation for distal radius fractures with metaphyseal and diaphyseal extension. Eur J Orthop Surg Traumatol. 2013 ; 23 (4): 407-15.
Kumbaraci M, Kucuk L, Karapinar L, Kurt C, Coskunol E. Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures. Eur J Orthop Surg Traumatol. 2014 ; 24 (2): 173-8.
Roh Y, Lee B, Baek J, Noh J, Gong H, Baek GH. A randomized comparison of volar plate and external fixation for intra-articular distal radius fractures. J Hand Surg Am. 2015 ; 40 (1): 34-41.
Tafoya-Arreguín GA, Martínez-Ruíz J, Rodríguez LM. Fractura de radio distal, correlación clínica-radiográfica posterior a fijación con placa volar. Acta Ortopédica Mexicana. 2013 ; 27 (1): 17-21.
Pattanashetty OB, Bhavi S, Bami M, Daultani D, Mapari Y. Outcome of fracture distal end of radius in adults treated by open reduction and internal fixation with buttress plate. Kerala Journal Of Orthopaedics. 2013 ; 26 (2): 87-92.