Balloon-assisted technique in complex anatomy of transulnar access route
Language: Spanish
References: 4
Page: 240-242
PDF size: 237.91 Kb.
ABSTRACT
Transulnar and transradial approaches have clear advantages in cardiac catheterization. However, complex anatomical variations can be the cause of failure in the use of this procedure. The case of a patient with complex arterial anatomy who underwent the balloon-assisted technique is reported. This technique is considered to be useful in selected cases.REFERENCES
Rodríguez Blanco S, Leyva Quert A, Valdés Recarey M, Almeida Gómez J, Ponte González G, García Hernández RA. Vía de acceso transradial. Evidencia científica y curva de aprendizaje. Rev Cubana Cardiol Cir Cardiovasc [Internet]. 2014 [citado 11 Abr 2015];20:123-30. Disponible en: http://www.revcardiologia.sld.cu/index.php/revcar diologia/article/view/522/624
Rodríguez Blanco S, Leyva Quert A, Valdés Recarey M, Almeida Gómez J, Ponte González G, Aguilar Medina JM, et al. Cateterismo cardiaco por vía transulnar. ¿Una segunda opción? Rev Cubana Cardiol Cir Cardiovasc [Internet]. 2015 [citado 11 Abr 2015];21:66-9. Disponible en: http://www.revcardiologia.sld.cu/index.php/revcar diologia/article/view/582/pdf_4