2015, Number 2
<< Back Next >>
Rev Cub Oftal 2015; 28 (2)
Diagnosis and control of astigmatism in the crystalline surgery
Ramos PY, Medina PJC, Hernández SJR, Rodríguez SB, Pérez CEC, Gutiérrez CM, Rodríguez SS
Language: Spanish
References: 44
Page: 205-219
PDF size: 241.47 Kb.
ABSTRACT
The present literature review was aimed at finding out the surgical options for the
preoperative and postoperative correction of astigmatism in the cataract surgery. The
addressed topics were detailed preoperative studies that allow customized surgical planning as well as several current solutions including anartigmatic incisions in
phacoemulsification and relaxing limbal incisions either combined or not and Excimer
laser procedures. Several research studies comprising various years up to the present
were consulted to learn about different results from the use of these surgical methods
as well as the most state-of-the-art techniques under study such as fentosecond laser
and light-adjustable intraocular lenses. All this may maximize the total refractive
correction and achieve optimal visual quality and better quality of life for the patient.
It is not easy to reach complete refractive correction but it is possible and should be
the goal to be accomplished by every cataract surgeon.
REFERENCES
Osher RH. Comportamiento del astigmatismo en la cirugía de cataratas. Los Angeles: Paper presented at the Annual Meeting of the American Intraocular Implant Society; 1984.
Osher RH. Transverse astigmatic keratotomy combined with cataract surgery. En: Thompson KP, Waring GO, eds. Contemporary Refractive Surgery-Ophthalmology Clinics of North America. Philadelphia: WB Saunders Co; 1992. p. 717-25.
Maloney WE. Refractive cataract replacement: a comprehensive approach to maximize refractive benefits of cataract extraction. Los Angeles: Paper presented at the annual meeting of the American Society of Cataract and Refractive Surgery; 1986.
Tejera Ferriol N. Astigmatismo y cirugía de catarata. En: Río Torres M. Oftalmología. Criterios y tendencias actuales. La Habana: Editorial Ciencias Médicas; 2009. p. 245-57.
Chayet A, Sancho C, Torres L. Procedimientos refractivos antes de la cirugía de catarata y durante esta. Ajuste del resultado al objetivo. En: Alió JL, Rodríguez-Prats JL. Buscando la excelencia en la cirugía de catarata. Alicante: Editorial Glosa; 2006. p. 337-45.
Curbelo L, Hernández JR, Machado EJ, Padilla CM, Ramos M, Río Torres M, et al. Frecuencia de ametropías. Rev cubana Oftalmol. 2005[citado 31 de agosto de 2011];18(1):[aprox 25 p.]. Disponible en: http://scielo.sld.cu/pdf/oft/v18n1/oft06105.pdf
Ferrer T, Montés-Micó R, Peixoto-de-Matos SC, González-Méijome JM, Cerviño A. Prevalence of corneal astigmatism before cataract surgery. J Cataract Refract Surg. 2009;35(1):70-5.
Hashemi H, Hatef E, Fotouhi A, Mohammad K. Astigmatism and its determinant in Tehran population: the Tehran eye study. Ophthalmic Epidemiol. 2005;12(6):373-81.
García CA, Orecife F, Nobre GF, Souza D de B, Rocha ML, Vianna RN. Prevalence of refractive errors in students in Northeastern Brazil: Arq Bras Oftalmol. 2005;68(3):321-5.
Cristóbal JA, del Buey MA, Mateo AJ. Astigmatismo y catarata. En: Centurión V, Nicoli C, Villar-Kouri J (editores). El libro del Cristalino de las Américas. Sao Paulo: Livraria Santos; 2007. p. 819-43.
Daponte P. Cirugía refractiva de catarata. Médico Oftalmólogo. 2002;15(1):1.
Freydell H. Astigmatismo en cirugía de cataratas. En: Centurión V, Nicoli C, Villar- Kouri J (editores). El Cristalino de las Américas. Sao Paulo: Livraria Santos; 2007. p. 811-7.
Hernández Silva JR, Curbelo Cunill L, Fernández Vázquez G, Ramos López M, Rio Torres M, Rios Caso R, et al. Evolución y técnicas de la microfacoemulsificación en Cuba. En: Río Torres M, Capote Cabrera C, Hernández Silva JR, Eguía Martínez F, Padilla González CM. Oftalmología Criterios y Tendencias Actuales. La Habana: Editorial Ciencias Médicas; 2009. p. 259-65.
Ibáñez Hernández MA, Ramos Espinoza K. Astigmatismo inducido en facoemulsificación con incisiones de 3,0 mm ampliadas a 3,75 mm. Rev Mex Oftalmol. 2004;78(5):245-9.
Osher RH. Combining phacoemulsification with corneal relaxing incisions for reduction of preexisting astigmatism. Los Angeles: Paper presented at the Annual Meeting of the American Intraocular Implant Society; 1984.
Grunstein LL, Miller KM. Astigmatism management at the time of cataract surgery. Expert Rev Ophthalmol. 2011;6(3):297-305.
Hernández Silva JR, Toxqui Abascal V, Río Torres M, Ramos López M, Curbelo Cunill L, Fernández Vásquez G, et al. Facoemulsificación y queratotomía astigmática. Rev Cubana Oftalmol. 2007 [citado 31 de agosto de 2011];20(2):[aprox 12 p.]. Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864- 21762007000200008&lng=es&nrm=iso&tlng=es
Hernández Silva JR, Ramos López M, Curbelo Cunill L, Fernández Vásquez G, Rio Torres M, Ruiz Rodríguez Y. Astigmatismo posquirúrgico en la facoemulsificación según el lugar de la incisión. Rev Cubana Oftalmol. 2012;25(1):2-11.
Moreno Montañés J, Aliseda Pérez de Madrid D, Munuera Gil JM, García Layana A. Análisis vectorial del astigmatismo topográfico inducido en la incisión corneal temporal de 3 mm sin sutura. Stadium. 2007 [citado 31 de septiembre de 2011]:[aprox 8 p.]. Disponible en: http://www.oftalmo.com/studium/studium1997/stud97-2/b-03.htm
Pisella PJ. Post-operative residual astigmatism after cataract surgery: Current surgical methods of treatment. J Ophthalmol. 2012;35(3):226-8.
Gills JP. Cataract surgery with a single relaxing incision at the steep meridian. J Cataract Refract Surg. 1994;20(3):368-9.
Muller-Jensen K, Fischer P, Siepe U. Limbal relaxing incisions to correct astigmatism in clear corneal cataract surgery. J Cataract Refract Surg. 1999;15(5):586-9.
Lindstrom RL, Lindquist TD. Surgical correction of postoperative astigmatism. Cornea. 1988;7(2):138-48.
Maloney WF, Sanders DR, Pearcy DE. Astigmatic Keratotomy to correct preexisting astigmatism in cataract patients. J Cataract Refract Surg. 1990;16(3):297-304.
Álvarez de Toledo J. Corrección intraoperatoria del astigmatismo en la cirugía de la catarata. En: Alió JL, Rodríguez-Prats JL. Buscando la excelencia en la cirugía de catarata. Alicante: Editorial Glosa; 2006. p. 348-59.
Woodcock M, Shah S, Smith RJ. Recent Advances in Customising Cataract Surgery. BMJ. 2004;328(7431):92-6.
Ben Simon GJ, Desatnik H. Correction of pre-existing astigmatism during cataract surgery: comparison between the effects of opposite clear corneal incisions and a single clear corneal incision. Graefes Arch Clin Exp Ophthalmol. 2005;243(4):321-6.
Price FW, Grene RB, Marks RG, Gonzales JS. Astigmatism Reduction Clinical Trial: a multicenter prospective evaluation of the predictability of arcuate keratotomy. Evaluation of surgical nomogram predictability. ARC-T Study Group. Arch Ophthalmol. 1995;113(3):277-82.
Nichamin LO. Astigmatism control. Ophthalmol Clin North Am. 2006;19(4):485- 93.
Grunstein LL, Miller KM. Astigmatism management at the time of cataract surgery. Expert Rev Ophthalmol. 2011;6(3):297-305.
Mendicute J. Lente intraocular Acrisoft Tórica. Alicante, España: Refractiva Internacional; 2008 [citado 31 de septiembre de 2011]. Disponible en: http://www.congresoari.com/cursos/040/player.html
Alió J, Ortiz D. Lente intraocular Acritec Tórica. Alicante, España: Refractiva Internacional; 2008 [citado 31 de septiembre de 2011]. Disponible en: http://www.congresoari.com/cursos/039/player.html
Holland E, Lane S, Horn JD, Ernest P, Arleo R, Miller KM.The AcrySof Toric intraocular lens in subjects with cataracts and corneal astigmatism: a randomized, subject-masked, parallel-group, 1-year study. Ophthalmology. 2010; 117(11):2104- 11.
Rongé LJ. Intraoperative treatment options astigmatic keratotomy. Correcting astigmatism during cataract surgery. EE.UU.: American Academy of Ophtalmology; 2013.
Goggin M, Moore S, Esterman A. Toric intraocular lens outcome using the manufacturer's prediction of corneal plane equivalent intraocular lens cylinder power. Arch Ophthalmol. 2011;129(8):1004-8.
Rodríguez Reyes A. Efectos titulares de láser excimer. En: Sánchez Galeana C. Lasik-Lasek, nuevos horizontes en la calidad de visión. Panamá: Highlight of Ophthalmology; 2003. p. 43-50.
Camellin M. Lasek. En: Sánchez Galeana C. Lasik-Lasek. Nuevos horizontes en la calidad de visión. Panamá: Highlight of Ophthalmology; 2003. p. 267-74.
Netto MV, Takashi C, Barreto J, Carricondo P. Astigmatismo elevado. En Centurión V, Nicoli C, Villar-Kouri J (editores). El libro del Cristalino de las Américas. Sao Paulo: Livraria Santos; 2007. p. 845-53.
Arriola-Villalobos P, Díaz-Valle D, Güell JL, Iradier-Urrutia MT, Jiménez-Alfaro Cuiña-Sardiña R, Benítez-del-Castillo JM. Intrastromal corneal ring segment implantation for high astigmatism after penetrating keratoplasty. J Cat Refrac Surg. 2009;35(11):1878-84.
Müller-Jensen K, Fischer P. Minimizing induction of astigmatism in preoperative spherical cornea a. by mini-incision surgery with foldable IOL and b. by corneal tunnel incision with limbal relaxing incision. Klin Monbl Augenheilkd. 1999;215(3):158-62.
Oshika T, Sugita G, Tanabe T, Tomidokoro A, Amano S. Regular and irregular astigmatism after superior versus temporal scleral incision cataract surgery. Ophthalmology. 2000;107(11):2049-53.
Auffarth GU, Rabsilber TM, Kohnen T, Holzer MP. Design and optical principles of multifocal lenses. Ophthalmologe. 2008;105(6):522-6.
Lane SS, Morris M, Nordan L, Packer M, Tarantino N, Wallace RB. Multifocal intraocular lenses. Ophthalmol Clin North Am. 2006;19(1):89-105.
von Mohrenfels C, Salgado J, Khoramnia R, Mathias M, Lohmann C. Resultados de cirugía de cataratas con lentes intraoculares ajustables con la luz. J Refract Surg. 2010;26:314-20.