2015, Number 06
Next >>
MediSan 2015; 19 (06)
Vascular ultrasonography in patients with chronic hepatopathies of unknown etiology
Rosales FY, Simón PL, Nieves MJD
Language: Spanish
References: 20
Page: 708-714
PDF size: 45.54 Kb.
ABSTRACT
A prospective and cross-sectional study of 69 patients with chronic hepatopathies of
unknown etiology, assisted in the Imagenology Department of "Saturnino Lora Torres"
Teaching Provincial Clinical Surgical Hospital in Santiago de Cuba was carried out from
January, 2009 to August, 2010, in order to determine the ultrasonographic vascular
changes in the affected patients. The age group 52-59 (39.1%), the male sex (69.6%),
the localization (44.9%), the thromboses of the portal vein (47%), the dilation of
suprahepatic veins (89.7%) and the prehepatic etiologies (44.9%) prevailed. The Doppler
duplex and Doppler colour echographies allowed to establish diagnostic criteria in these
patients, without affecting their evaluation with other hemodynamic studies.
REFERENCES
Mostbeck GH, Wittich GR, Herold C, Vergesslich KA, Walter RM, Frotz S, et al. Hemodynamic significance of the paraumbilical veins in portal hypertension: assessment with duplex U.S. Radiology. 1989; 170(2):339-42.
Ohnishi K, Saito M, Aat SL. Direction of splenic venous flow, assessed by pulsed Doppler flowmetry in patientes with a large splenoportal shunt. Gastroenterology. 2000; 156:250-76.
Okuda K, Ohnishi k, Kimura k, Matsutani S, Sumida M, Goto N, et al. Incidence of portal vein thrombosis in liver cirrhosis. An angiographic study in 708 patients. Gastroenterology. 1985; 89(2):279-86.
Perisi M, Dyulaic DJ, Sagic D, Orbic R. Doppler- duplex ultrasonography in the diagnosis of cavernous portal vein. Srp Arh Celok Lek. 1998; 126(9-10):368-73.
Kawasaki T, Moriyasu F, Nishida O, et al. Analysis of hepatofugal flow in portal venuos system using ultrasonic Doppler duplex system. Am J Gastroenterol. 1989; 84(8):937- 41.
Foster DN, Herlinger H, Miloszewski KJ, Losowsky MS. Hepatofugal portal blood flow in hepatic cirrhosis. Ann Surg. 1978; 187(2):179-82.
Bolondi L, Gaiani S, Simoncelli M, Rigamonti A, Zironi C, Siringo S, et al. Changes of hepatic venous flow in liver disease assessed by Doppler US relationship with histology. J Hepatol. 1991; 13(suppl 2):98.
Ohnishi K, Saito M, Koen H, Nakayama T, Nomura F, Okuda K. Pulsed Doppler flow as a criterion of portal venous velocity: comparison with cineangiographic measurements. Radiology. 1985; 154(2):495-8.
Okasaki K, Miyazaki M, Ohnishi S, Ito K. Effects of food intake and various extrinsic hormones on portal blood flow in patients with liver cirrhosis demostrated by pulsed Doppler with the Octoson. Scan J Gastroenterol. 1986; 21(9):1029-38.
Ulloa Arias B, González de la Paz JE, Álvarez Guerra O, Castellanos Carmenatte T. Infecciones hepatobiliares y nuevas especies helicobacter. Ciencia en su PC. 2008 [citado 1 Ago 2010]; 4.
Ulloa Arias B, Álvarez Guerra O, Castellanos Carmenate T, González de la Paz JE, Reyes Abich D. Medios de diagnóstico aplicados para la confirmación de enfermedades hepatobiliares. MEDISAN. 2009 [citado 1 Ago 2010]; 13(2):
Ulloa Arias B, Carvajal Beltrán JF, González de la Paz JE, Ramos Dinza M, Mustelier Ferrer HL. Flora bacteriana intestinal en pacientes con hepatopatías crónicas. MEDISAN. 2010 [citado 1 Ago 2010]; 14(5):
Ljubicic N, Duvnjak M, Rotkvic I, Kopjar B. Influence of the degree of liver failure on portal blood flow in patients with liver cirrhosis. Scand J Gastroenterol. 1990; 25(4): 395-400.
Salá R, Andrew M,Cell S, Vila HC, Oliver MI, Arroyo V. Spontaneous bacterial peritonitis in cirrhotic patiens treated using paracentesis or diuretics: results of a randomized study. Hepatology. 1995;21(2):340-4.
Roguin A. Christian Johann Doppler: the man venid the effect. Brit J Radiol. 2002; 75:615-92.
Alexandrov AV, Sloan MA, Wong LK, Douville C, Razumovsky AY, Koroshetz WJ, et al. Practice standards for transcranial Doppler ultrasound: Part I test performance. J Neuroimaging. 2007; 17(1):11-8.
Mayer J, Klemm M, Hufnagel D, Wagenfeld L, Galambos P, Wiermann A, et al. Dynamic color Doppler imaging (dCDI): effect of flicker stimulation on the blood flow velocities in the retrobulbar arteries in healthy volunteers and glaucoma patients. Invest Ophthalmol Vis Sci. 2008; 49:4136.
Uriza F, Useche N. Ultrasonido Doppler color en glaucoma: estudio de concordancia. Rev Colomb Radiolog. 2005; 16(1):1664-70.
Pickett MA, Harris A, Siesky B, Ehrlich R, Moss A, Cantor L, et al. The Indianapolis Glaucoma Progression Study: reproducibility of color Doppler imaging. Invest Ophthalmol Vis Sci. 2009; 50:5266-74.
Álvarez Guerra OM, Ulloa Arias B, Fernández Duharte J, Castellanos Carmenatte T, González de la Paz JE. Afecciones digestivas más frecuentes en el adulto mayor. MEDISAN. 2010 [citado 1 Ago 2010]; 14(4):