Objective. To prove the effectiveness of LCP (locking compression plate) used by the Department of Orthopedics of the Mexican Red Cross Central Hospital and verify the time needed for fracture consolidation with the use of LCP.
Material and methods. One hundred and twenty six fractures were analyzed prospectively in 105 patients. All of which were treated with LCP plates in a period of time of 24 months (from January 1° 2003 to December 31 of 2004). Radiological monitoring was carried out in the following fourth, eight and twelfth weeks.
Results. It was found a greater frequency in male patients, with 90 patients (86%) rather than in female patients with 15 cases (14%). Seventy two percent of the injuries happened within a productive age period. Sixty five percent (81 fractures) of the patients was treated with LCP of 3.5 mm. The required time for consolidation in 50% of the cases (63 fractures) was from 7 to 9 weeks.
Conclusions. The consolidation time was reduced with the use of LCP even the open fractures. The complications were considerably less frequent with the use of LCP plates. The most affected osseous region were those of the forearm (radius and ulna). The age group most frequently affected was that of the patients between 21 to 30 years.
REFERENCES
Perren SM, Klaue K, Frigg R, Predieri M, Tepic S: (in prep) The concept of biological plating: The Limited-contact dynamic compression plate LCDCP. Orthop Trauma. 1991.
Müller ME, Allgöwer M, Villenegger H: Technik der operativen frakturenbehandlung. Springer, Berlin. 1963.
Allgöwer M: Cinderella of surgery – fractures? Surg Clin North Am 1978; 58: 1071-1093.
Allgöwer M: The dynamic compression plate, Springer-Verlag Berlin Heidelberg, New York. 1973.
Klaue K: The dynamic compression unit for stable internal fixation of bone fractures. Med Diss Basel 1982.
Brunner CF, Weber BG: Besondere Osteosynthesetechniken, Springer, Berlin Heidelberg New York. 1981.
Heitemeyer U, Hierholzer G: Die überbrückende Ostheosyntese bei geschlossenen stuckfrakturen des femurschaftes. Akt Ttraumatol 1982; 15: 205-209.
Klaue K, Perren SM: Fixation interne des fractures par I’ensemble plaque-vis a compression conjuguee (DCU). Helv Chir Acta 1982; 49: 77-80.
Mast J, Jakob R, Ganz R: Planning and reduction technique in fracture surgery Springer, Berlin Heidelberg New York. 1989.
Baumgaertel F, Buhl M, Rahn BA: Fracture healing in biological plate osteosynthesis. Injury 1998; 29: C3-5.
Williamns DF. A model of biocompatibility and its evaluation. J Biomed Eng 1989; 11(3):185-191
Marti A, Fankhauser C, Frenk A: Biomechanical Evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures. J Orthop Trauma 2001; (7): 482-487.
Arens S, Kraft C, Schlegel U, et al: Susceptibility to local infection in biological internal fixation. Experimental Study of open vs minimally invasive plate osteosynthesis in rabbits. Arch Orthop Trauma Surg 1999; 119: 82-85.
Rhinelander FW: Physiology of bone from vascular viewpoint. Society for biomaterials, San Antonio, Texas 1878; 2: 24-26.
Perren SM: Evolution of the internal fixation of long bone fractures. JBJS 2002; 84: B1093-1110.
Faruvk O, Krettek C, Miclau T, et al: Effects of percutaneous and conventional plating techniques on the blood supply to the femur. Arch Orthop Trauma Surg 1988; 117: 438-441.
Rhinelander FW, Wilson JW: Blood supply in developing mature and healing bone In: Summer Smith G (ed). Bone in clinical Orthopaedics. Saunders, Philadelphia. 1982.
Gautier E, Cordey J, Mathys R, Rahn BA, Perren SM: Porosity and remodeling of plated bone after internal fixation: results of stress shielding or vascular damage? Elsever Science Amsterdam. 1984.
Lüthi UK, Rahn BA, Perren SM: Implants and intracortical vascular disturbances 28th Annual ORS Meeting 1982: 337.
Fernandez Dell´Oca: The principle of helical implants. Injury AO 2002; 33(Suppl 1):B44-50
Baumgaertel F, Perren SM, Rahn B: Animal experiment studies of “biological” plate osteosynthesis of multifragment fractures of the femur. Unfallchirung 1994; 97: 19-27.