2014, Number 1
<< Back Next >>
Rev Cub Med Mil 2014; 43 (1)
Myopia correction by Lasik surgery
Escalona TMJ, Torres OR, Welch RG, Martínez RJ, Zerquera RT
Language: Spanish
References: 11
Page:
PDF size: 67.54 Kb.
ABSTRACT
Objective: identify refractive results and complications following myopia correction by
LASIK.
Methods: 241 eyes which had been operated on by LASIK were divided into 4 groups
based on the degree of myopia and astigmatism. Patients underwent a complete
preoperative ophthalmological study before they were operated on. After surgery,
myopic and astigmatic patients were evaluated for visual acuity, as well as
intraoperative and postoperative complications during the first month and in a threemonth
follow-up period.
Results: previous corrected visual acuity was preserved and no serious or irreversible
complications were detected.
Conclusions: LASIK is a safe myopia correction technique useful to improve
spontaneous visual acuity and reduce optical correction.
REFERENCES
Pallikaris IG, Vikentia JK, Panagopoulos Sl. Laser in situ keratomileusis Intraoperative Complications Using One type of Microkeratome. Ophthalmology. 2002;109:57-63.
Lawless MA, Hodge C, Roger CM, Sutton GL. Laser in situ keratomileusis with Alcon Custom Cornea. J Refract Surg. 2003 Nov-Dec;19(6):S691-6.
Boyd BF. Cirugía refractiva. Las últimas técnicas. Highlights Ophthalmol (Hispanoamerica, Panama). 2003:2(27):14-22.
Amanos S, Shimizu K, Tsubota K. Corneal epithelial changes after excimer laser photorefractive keratectomy. Am J Ophthalmol 2000;115:441-3.
Claringbold I, Thomas V. Laser-assisted subepithelial keratectomy for the correction of myopia. J Cataract Refract Surg. 2002(28):18-22.
Scerrati E. Laser in situ keratomileusis (LASIK-LASEK). J Refract Surg. 2001;17(2 Suppl):S219-21.
Morillo Sanchez MJ, Rivera de Zea P, Vazque Salvi A, Minaya Martinez F, Garcia Campos JM. Estudio de membranas neovasculares subretinianas secundarias a miopía degenerativa. Arch Soc Esp Oftalmología. 2001;76:357-62.
Alfonso JF, Fernandez-Vega L, Montés-Mico R. 1-Year Follow-up of phakic Implantable.collamer lens for low myopia. J Emmetropia. 2010;1:3-8.
Curbelo CL, Hernandez SJ, Machado FE. Frecuencias de Ametropias. Instituto Cubano de Oftalmología. Rev Cubana Oftalmología 2005;10(2):6-8.
Lombardo M, De Santo MP, Lombardo G, Barberi R, Serrao S. Roughness of excimer laser ablated corneas with and without smoothing measured with atomic force microscopy. J Refract Surg. 2005;21(5):469-75.
Benítez MC, Machado E. Lasek: Resultados en dos años. Rev Cubana Oftalmol [Internet]. 2006 [citado 15 Feb 2013];19(1). Disponible en: http://scielo.sld.cu/scielo.php?pid=S0864- 21762006000100004&script=sci_arttext&tlng=en