Development of a three-dimensional model of a bone of the hip by means of the method of the finite element
Araujo MVM, Domínguez HVM, Urriolagoitia CG
Language: Spanish
References: 12
Page: 160-164
PDF size: 137.87 Kb.
ABSTRACT
There is described the development of a three-dimensional model of a bone of the human hip by means of the method of the finite element. The geometry of the bone decided across 84 courts tomographies practiced the bone of the hip of a patient of feminine sex, 60 years, 1.55 m, 70 kg of weight, before the surgical intervention. Once digitized the cuts tomographies, there fed the information obtained to the software Ansys version 6.1. The developed model consisted of 95,943 elements and of 160,220 nodes. This model will serve as reference to different cases in which it is needed of Studying and Analyzing the biomechanics of a bone of the hip submitted to charges, and in the cases where prosthesis and implants are applied for hip.
REFERENCES
Brekelmans WAM, Poort HW, Slooff TJ. A new method to analyse the mechanical behaviour of skeletal parts. Acta Orthop Scandinavica 1972; 43: 301-317.
Huiskes R, Chao EYS. A survey of finite element analysis in orthopaedic biomechanics: The first decade. J Biomech 1983; 6(2): 385-409.
Prendergast PJ. Finite element models in tissue mechanics and orthopaedic implant design. Clin Biomech 1997; 12(6): 343-366.
Domínguez HVM, Carbajal RMF, Feria RCV, Urriolagoitia CG, Hernández GLH, Rico MG, Damián NZ, Lomelí MPA. Biomecánica de un fémur sometido a carga. Desarrollo de un modelo tridimensional por medio del método del elemento finito. Rev Mex Ortop Traum 1999; 13(6):633-638.
Araujo MVM. Optimización del diseño de un espaciador para el tratamiento de tumores de rodilla. Tesis de Licenciatura, UPIITA, IPN. México, 2002.
Domínguez HVM, Araujo MVM, Silva LJJ, Rico MG. Riesgo de fractura del clavo intramedular en un espaciador tumoral para rodilla. Rev Mex Ing Biomed 2003; 24(2): 144-154.
Keyak JH, Meagher JM, Skinner HB, Mote CD. Automated three-dimensional finite element modeling of bone: A new method. J Biomed Eng 1990; 12: 389-397.
Mann KA, Bartel DL, Wright TM, Burstein AH. Coulomb frictional interfaces in modeling cemented total hip replacements: a more realistic model. J Biomech 1995; 28(9): 1067-1078.
Rico MG, Linares GLM, Domínguez HVM. Prótesis tumoral no convencional bloqueada para cadera. Rev Mex Ortop Traum 1997; 11(6): 385-388.
Dalstra M, Huiskes R. Load transfer across the pelvic bone. J Biomech 1995; 28(6): 715-724.
Verdonschot N, Vena P, Huiskes R. Thickness variation of metal inlays in UHMWPE cups with metal-on-metal bearing THA surfaces. Proceedings of the Orthopaedic Research Society, 1997: 9-13.
Wroblewski BM, Siney PD, Fleming PA. Wear and fracture of the acetabular cup in charnley low-friction arthroplasty. J Arthroplasty 1998; 13(2): 132-137.