ABSTRACT
Background. Detection of hyperbilirubinemia in newborn has become
a challenge for health care systems. The aim of the study was to prove
the usefulness of concurrent total transcutaneous bilirubin measurement
over forehead (TTBf) and total transcutaneous bilirubin over sternum
(TTBs) as predictive model for total serum bilirubin (TSB) in premature
and term newborns.
Material and Method. Transversal and analytical study in 30-42 gestation
week newborns from January 21
st to April 30
th 2013 in a gynecology,
obstetrics and neonatology specialties public hospital. Pearson´s correlation
for TSB/TTBf and TSB/TTBs was carried out. Linear regression
analysis for one and several predictive variables were performed.
Results. For 89 concurrent measurements, the correlation TSB/TTBf
was 0.8411 and for TSB/TTBs, 0.7942 (p value ‹ 2.2E-16 in both
cases). With simple regression analysis for TSB and TTBf, the equation
was: TSB = 2.1187 + 0.7035 × TTBf (
p ‹ 2.2E-16, R
2 = 70.75%,
R
2
adjusted = 70.41%); for TSB and TTBs the equation was: TSB = 2.0405
+ 0.6349 × TTBs (
p ‹ 2.2E-16, R
2 = 63.07%, R
2
adjusted = 62.65%). With
multiple regression analysis for TSB
vs. TTBf, TTBs, the equation was:
BTS = 1.620 + 0.503 × TTBf + 0.224 × TTBs (p ‹ 2.2 E-16, R
2 = 72.87%,
R
2
adjusted
= 72.24%).
Conclusions. It was demonstrated that TTBf, TTBs model allowed to
obtain better TSB prediction than TTB single measurement models for
in-patient premature and term newborns.
REFERENCES
Management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation. Pediatrics 2004;114:297- 316.
Maisels MJ, Bhutani VK, Bogen D, Newman TB, Stark AR, Matchko JF. Hyperbilirubinemia in the newborn infant 35 weeks gestation: an update with clarifications. Pediatrics 2009;124:1193-98.
Jiménez B, Miguel MA, Acosta JM, Fernández MP. Detección no invasiva de hiperbilirrubinemia: evaluación clínica y bilirrubina transcutánea con bilirrubina sérica. Rev Sanid Milit Mex 2010;64:54-60.
Rubaltelli FF, Gourley GR, Loskamp N, Modi N, Roth-Kleiner M, Sender A, Vert P. Transcutaneous Bilirubin Meassurement: A Multicenter Evaluation of a New Device. Pediatrics 2001;107:1264-71.
Bhutani BK, Gourly GR, Adler S, Kreamer B, Dalin Ch, Johnson LH. Noninvasive Measurement of Total Serum Bilirubin in a Multiracial Predischarge Newborn Population to Assess the Risk of Severe Hyperbilirubinemia. Pediatrics 2000;106;e17.
Romagnoli C, Tiberi E, Barone G, De Curtis M, Regoli D, Paolillo P, et al. Validation of transcutaneous bilirubin nomogram in identifying neonates not at risk of hyperbilirubinaemia: A prospective, observational, multicenter study. Early Hum Dev 2012;88:51-5.
Jangaard KA, Curtis H, Goldbloom RB, Hon D. Estimation of bilirubin using BiliChekTM, a transcutaneous bilirubin measurement device: Effects of gestational age and use of phototherapy. Paediatr Child Health 2006;11:79-83.
Fouzas S, Mantagou L, Skylogianni E, Mantagos S, Varvarigou A. Transcutaneous Bilirubin Levels for the First 120 Postnatal Hours in Healthy Neonates. Pediatrics 2010;125; e52.
Holland L, Blick K. Implementing and Validating Transcutaneous Bilirubinometry for Neonates. Am J Clin Pathol 2009;132:555-61.
Poland RL, Hartenberger C, McHenry H, Hsi A. Comparison of Skin for Sites for Estimating Serum Total Bilirubin in In- Patientes and Out-Patients: Chest is Superior to Brow. J Perinatol 2004;24:541-3.
Ho E, Lee S, Chow C, Chung J. Bilicheck transcutaneous bilirubinometer: a screening tool for neonatal jaundice in the Chinese population. Hong Kong Med J 2006;12:99-102.
Stillova L, Matasova K, Mikitova T, Stilla J, Kolarovszka H, Zibolen M. Evaluation of Transcutaneous Bilirubinometry in Preterm Infants of Gestational Age 32-34 Weeks. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2007;151:267-71.
Rodríguez-Weber MA, López-Candiani C, Valencia-Salazar G, Millote-Galindo G. Eficacia de un analizador de bilirrubina no invasivo en neonatos. Bol Med Hosp Infant Mex 1999;56:539-42.
Draper NR, Smith H. Applied Regression Analysis. 3th edition. USA. Wiley Series in Probability and Statistics, 1998, pp. 327-68.
Engle WD, Jackson GL, Dendelbach D, Manning D, Frawley WH. Assessment of a Transcutaneous Device in the Evaluation of Neonatal Hyperbilirubinemia in a Primarly Hispanic Population. Pediatrics 2002;110:61-7.