2013, Number 4
<< Back Next >>
Acta Pediatr Mex 2013; 34 (4)
Neonatal screening to detect critical congenital cardiac disease. A revolution in pediatrics
Vela-Amieva M, Espino-Vela J
Language: Spanish
References: 15
Page: 237-240
PDF size: 624.21 Kb.
ABSTRACT
There is solid evidence that demonstrate the usefulness of routine oxygen saturation testing in every apparently healthy newborn after 24 hours of life and before 48 hours. This procedure is known as “newborn screening for critical congenital heart disease” and serves to detect timely those congenital structural cardiac malformations with hypoxema, such as heart syndrome, pulmonary valve atresia, truncus arteriosus, total anomalous pulmonary vein connection, complete transposition of the great arteries, tetralogy of Fallot and tricuspid valve atresia. This test has been included in the mandatory neonatal screening panel of many countries and its generalization all over the world, seems imminent.
REFERENCES
CDC. Ten great public health achievements. United Statres 2001-2010. Morbidity and Mortality Weekly Report. 2011;60:619-23.
Guthrie R, Susi A. A simple phenyalanine method for detecting phenylketonuria in large populations of newborn infants. Pediatrics. 1963;32:338-43.
Wilcken B, Wiley V, Hammond J, Carpenter K. Screening newborns for inborn error of metabolism by tandem mass spectrometry. N Engl J Med. 2003;348:2304-12.
Bennett MJ, Rinaldo P, Wilcken B, Pass KA, Watson MS, Wanders RJ. Newborn screening for metabolic disorders: how are we doing, and where are we going? Clin Chem. 2012;58:324-31.
Watson AS, Mann MY, Lloyd-Puryear MA, Rinaldo P, Howell RR. Newborn swcreening: toward a uniform panel and system. Exexutive Summary. Genet Med. 2006;8:S1-11.
Marino BS, Lipkin PH, Newburger JW, Peacock G, Gerdes M, Gaynor JW, et al. Neurodevelopmental outcomes in children with congenital heart disease: evaluation and management: a scientific statement from the America Heart Association. Circulation. 2012;126:1143-72.
Hoffman JI, Kaplan S. The incidence of congenital heart disease. J Am Coll Cardiol. 2002;39:1890-900.
Mahle WT, Newburger JW, Matherne GP, Smith FC, Hoke TR, Koppel R, et al. Role of pulse oximetry in examining newborns for congenital heart disease: a scientific statement from the American Heart Association and American Academy of Pediatrics. Circulation. 2009;120:447-58.
Kemper AR, Mahle WT, Martin GR, Cooley WC, Kumar P, Morrow R, et al. Strategies for implementing screening for critical congenital heart disease. Pediatrics. 2011;128:1259-67.
Riede FT, Wörner C, Dähnert I, Möckel A, Kostelka M, Schneider P. Effectiveness of neonatal pulse oximetry screening for detection of critical congenital heart disease in daily clinical routine: results form a prospective multicenter study. Eur J Pediatr. 2010;169:975-81.
Thangaratinam S, Brown K, Zamora J, Khan KS, Ewer AK. Pulse oximetry screening for critical congenital heart defects in asymptomatic newborn babies: a systematic review and metanalysis. Lancet. 2012;379:2459-64.
De-Wahl Granelli A, Wennergren M, Sandberg K, Mellander M, Bejlum C, Inganäs L, et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;338:a3037.
Frank LH, Bradshaw E, Beekiman R, Mahle WT, Martin GR. Critical congenital heart disease screeni9ng using pulse oximetry. J Pediatr. 2013;162:445-53.
Ewer AK, Middleton LJ, Furmston AT, Bhoyar A, Daniels JP, Thangaratinam S, et al. Pulse oximetry screening for congenital heart defects in newborn infants (PulseOx): a test accuracy study. Lancet. 2011;378(9793):785-94.
Ewer AK, Furmton AT, Middleton LJ, Deeks JJ, Daniels JP, Pattison HM, et al. Pulse oximetry as a screening test for congenital heart defects in newborn infants: a test accuracy study with evaluation of acceptability and cost-effectiveness. Health Technol Assess. 2012;16:v-xiii1-184.