Risk of Intramedullary Nail Fracture in a Spacer used for Knee Tumor Treatment
Domínguez HVM, Araujo MVM, Silva LJJ, Rico MG, Linares GLM, Delgado CE
Language: Spanish
References: 16
Page: 144-154
PDF size: 212.15 Kb.
ABSTRACT
Bone tumors affects the knee in most of the cases. A new design of a spacer developed reported satisfactory results. In one case implant has broken due to a fall, in the distal hole of femur. Corresponding interlocking pin has not been inserted. The spacer has been implanted after resection of a malignant fibrous histiocitoma in a 85-years-old female patient. A finite-element model of femur-tibia-spacer was developed, including loads that are verified in gait cycles. Displacements obtained showed no significant difference. In the case where distal interlocking pin of femur was absent, stresses were 95% higher than those verified with pin present, and it was 83% higher without pin and when the bone was not drilled. When the distal pin was located 1-5 cm from spacer, stresses did not show any significant difference with respect to those case with pin at 0.5 cm. It was also studied one load set that reproduces a lateral fall, finding that stresses at distal pin hole were higher than the strength of stainless steel (1,100 MPa), for the case without pin (2,638 MPa), and with pin (1,388 MPa). For the mentioned above, it is clear that the implant was broken due to the absence of distal pin, when the patient fell.
REFERENCES
Malawer MM, Chou LB. Prosthetic survival and clinical results with use of large-segmental replacements in the treatment of high-grade bone sarcomas. J Bone Joint Surg 1995; 77-A(8): 1154-1165.
Simon A. Current concept review. Limb salvage for osteosarcoma. J Bone Joint Surg 1988; 70A(2): 307-310.
Blunn GW, Briggs TWR, Cannon SR, Walker PS, Unwin PS, Culligan S, Cobb JP. Cementless fixation for primary segmental bone tumor endoprostheses. Clin Orthop 2000; 372: 223-230.
Arroyo JS, Garvin KL, Neff JR. Arthrodesis of the knee with a modular titanium intramedullary nail. J Bone Joint Surg 1997; 79A(1): 26-35.
Harris IE, Leff AR, Gitelis S, Simon MA. Function after amputation, arthrodesis, or arthroplasty for tumors about the knee. J Bone Joint Surg, 1990; 72A(10): 1477-1485.
Rico MG, Linares GLM, Díaz RL, de la Garza NM. Tratamiento de los tumores óseos mediante resección en bloque y colocación de clavo Colchero especial con espaciador metálico. Rev Mex Ortop Traum 1996; 12(5): 445-449.
Domínguez HVM. Optimización del componente femoral de una prótesis no convencional bloqueada para cadera. Tesis doctoral, Sección de Estudios de Postgrado e Investigación ESIME, IPN. México, 2000.
Domínguez HVM, Carbajal RMF, Feria RCV, Urriolagoitia CG, Hernández GLH, Rico MG, Damián NZ, Lomelí MPA. Biomecánica de un fémur sometido a carga. Desarrollo de un modelo tridimensional por medio del método del elemento finito. Rev Mex Ortop Traum 1999; 13(6): 633-638.
Kalidindi SR, Ahmad P. A numerical investigation of the mechanics of swelling-type intramedullary hip implants. J Biomech Eng 1997; (119): 241-247.
Van Rietbergen B, Müller R, Ulrich D, Rüegsegger P, Huiskes R. Quantitative assessment of tissue loading in proximal femur, using a full scale microstructural FE-model. Transactions of the 43rd Annual Meeting of the Orthopaedic Research Society, 1997: 62.
McNamara BP, Cristofolini L, Toni A, Taylor D. Relationship between bone-prosthesis bonding and load transfer in total hip reconstruction. J Biomech 1997; 30(6): 621-630.
Namba RS, Keyak JH, Kim AS, Vu LP, Skinner HB. Cementless implant composition and femoral stress. Clin Orthop 1998; 347: 261-267.
Huiskes R, Verdonschot N, Niubrant B. Migration, stem shape, and surface finish in cemented total hip arthroplasty. Clin Orthop 1998; 355: 103-112.
Gage JR, Deluca PA, Renshaw TS. Gait analysis. Principles and applications. Emphasis on its use in cerebral palsy. J Bone Joint Surg 1995; 77-A(10): 1607-1623.
Disegi JA, Eschbach L. Stainless steel in bone surgery. Injury 2000; 31S: D2-6.
Sabick MB, Hay JG, Goel VK, Banks SA. Active responses decrease impact forces at the hip and shoulder in falls to the side. J Biomech 1999; 32(9): 993-998.