2008, Number 4
<< Back Next >>
Rev Mex Patol Clin Med Lab 2008; 55 (4)
Haematological reference intervals in Highland Andean Ecuadorian Population, using the Sysmex XE-21000 blood counter
Sáenz FK, Narváez GL, Cruz M
Language: Spanish
References: 19
Page: 207-215
PDF size: 102.67 Kb.
ABSTRACT
Introduction: Hemogram is the most frequently ordered test for the evaluation of the health status of an individual. Its reference values are important in people that live in altitude, because of the decrease in the partial pressure of oxygen that affects the hemoglobin concentration, the hematocrit and other hematimetric parameters. In Quito, the last study of reference intervals was performed in 1985, using manual methods.
Material and methods: A descriptive epidemiological survey research study was performed. A sample of 2,613 hemograms was selected from adults of both sexes, and ages ranging from 18 to 45 years of age, submitted to Net-L@b S.A. (Quito), all of them performed for preventive health studies using the blood counter Sysmex XE-2100®.
Results: The average age of the subjects studied was 28.76 ± 7.6 years, and 53.6% of the subjects were males. Significative differences were found between the reference intervals calculated in this study and those reported in other publications about populations from different altitudes. The differences occurred in all the parameters evaluated, even if compared with populations located at a similar altitude than Quito.
Conclusions: These results underline the necessity for all laboratories to calculate the reference intervals from their own populations, or to justify the utilization of reference intervals calculated in other populations.
REFERENCES
NCCLS. How to define and determine intervals in the clinical laboratory; Approved Guideline. 2nd ed. NCCLS document C28-A2. USA, 2000.
Fraser CG. Biological variation: From principles to practice. USA: Am Assoc Clin Chem (AACC), 2001; p. 91-92, 104-109.
Solberg HE, Stamm D. IFCC recommendation: The theory of reference values. Part 4. Control of analytical variation in the production, transfer and application of reference values. J Autom Chem 1991; 13 (5): 231-234.
ISO/IEC 15189:2007. Laboratorios Clínicos – Requisitos particulares para la calidad y la competencia. 2007.
Almaguer GC. Interpretación clínica de la biometría hemática. Med Univer 2003; 5 (18): 35-40.
Beall CM, Brittenham GM, Stohl KP, Blangero J, Williams-Blanguero S, Goldstein MC et al. Hemoglobin concentration of High Attitude Tibetans and Bolivian Aymara. Am J Phys Anthropol 1998; 106: 385-400.
Hadary CJ, Hass JD. Hemoglobin correction factors for estimating the prevalence of iron deficiency anemia in pregnant women residing at high altitudes in Bolivia. Rev Panam Sal Pub 1999; 6 (6): 392-399.
Terrés SAM, Razo MD. Fórmula roja: Límites de referencia biocronológicos y niveles de decisión clínica en población mexicana. Rev Med IMSS 2000; 38 (4): 313-321.
Instituto Nacional de Ciencia y Tecnología. Ministerio de Salud Pública del Ecuador. Valores de Hemoglobina en Población Ecuatoriana. Quito, 1999.
Gomez de la Torre PJC, Bustinza LE, Huarachi A. Valores de referencia de algunas pruebas bioquímicas y hematológicas en personas adultas sanas del Hospital Central de la Fuerza Aérea del Perú 2000–2001. Rev Mex Patol Clin 2003; 50 (1): 41-49.
Echagüe G, Díaz V, Pistilli N, Méndez J, Ríos R et al. Valores hematológicos en donantes de bancos de sangre de Asunción, Paraguay. Disponible en: http://www.iics.una.py/VALORES%20 HEMATOLOGICOS.pdf
Lugada ES, Mermin J, Kaharuza F, Ulvestad E, Were W et al. Population-based hematologic and immunologic referent values for a Healthy Ugandan Population. Clin Diagn Lab Immunol 2004; 11 (1): 29-34.
Cruz Roja Ecuatoriana, Consejo Nacional de Ciencia y Tecnología (CONACYT). Valores normales de hematócrito, leucocitos, y fórmula leucocitaria para la sierra y la costa ecuatorianas. [Boletín]. Quito, 1985.
Ricos C, Alvarez V, Cava F, Garcia-Lario JV, Hernandez A, Jiménez CV, Minchinela J, Perich C, Simon M. Current databases on biologic variation: Pros, cons and progress. Scand J Clin Lab Invest 1999; 59: 491-500.
Fernandez LE, Bustamante Y, García G. Valores de referencia obtenidos con el autoanalizador Coulter Gen-S. RFM 2006; 29 (1): 38-43.
Rodríguez MA, Schlottfeldt V, Inchaustegui JL, Herrera C, Rosales M. Intervalos de confianza de la fórmula eritrocítica en habitantes adultos de la ciudad de Comitán de Domínguez (Chiapas, México). Higiene y Sanidad Ambiental, 2007; 7: 270-275.
Coy Velandia LS, Castilo M, Mora AI, Munevar A, Peña Y. Características hematológicas de donantes de sangre de Bogotá, D.C., Colombia (2600m). Rev Med 2007; 15 (1): 40-47.
Sysmex Corporation. XE-2100 Analizador hematológico automático: Instrucciones de uso. Sysmex Corporation, 2001. 13-15.
Solberg HE, Lhati A. Detection of outliers in reference distributions: Performance of Horn´s Algorithm. Clin Chem 2005; 51 (12): 2326-2332.