2023, Number 1
<< Back Next >>
Acta Ortop Mex 2023; 37 (1)
Results of the treatment of irreparable rotator cuff ruptures with the use of the subacromial balloon
Sola-Duque B, Hernández-Mateo J, López-Mombiela F, Aburto-Bernardo M, Pérez-Martín A, Álvarez-González J
Language: Spanish
References: 42
Page: 9-13
PDF size: 130.87 Kb.
ABSTRACT
Introduction: arthroscopic surgical treatment of rotator cuff tendon injuries has replaced open surgery as the first treatment option. Different surgical techniques have been described for massive or irreparable ruptures, and recently, a new device that consists of a biodegradable subacromial spacer between the humeral head and the acromion has been used. The present study aims to analyse the results of this implant in our experience.
Material and methods: we conducted an observational and retrospective study of all patients undergoing subacromial spacer implantation at our centre from 2017 to 2019. Patients were assessed pre- and postoperatively using the Constant, DASH and VAS scales.
Results: a total of 43 patients met the inclusion criteria and the minimum follow-up of 24 months. The mean DASH scale score went from 53.6 at preoperative assessment to 27.9 at postoperative assessment (p = 0.026). There was also a significant improvement in the Constant scale from a mean of 37.9 to 61.8 (p = 0.037). In terms of pain assessment, the mean VAS went from a mean of 7.44 to 3.38 (p = 0.916). In 90% of patients no complications or need for further interventions were objectified.
Conclusions: the subacromial balloon has shown favorable results in our series of patients, so it could be a valid treatment option in patients with non-repairable rotator cuff tears.
REFERENCES
Morse K, Davis AD, Afra R, Krall Kaye E, Schepsis A, Voloshin I. Arthroscopic versus mini-open rotator cuff repair: A comprehensive review and meta-analysis. Am J Sports Med. 2008; 36(9): 1824-8.
Ruiz Ibána MA, Pérez Expósito R, Díaz Heredia J, Garcia Navlet M, Cuéllar R, Ávila Lafuente JL, et al. Reparación artroscópica de las roturas del manguito rotador. Rev Esp Artrosc Cir Articul. 2014; 21(2): 109-19.
Gerber BYC, Fuchs B, Hodler J. The results of repair of massive tears of the rotator cuff. J Bone Jt Surg. 2000; 82(4): 505-15.
Le BTN, Wu XL, Lam PH, Murrell GAC. Factors predicting rotator cuff retears: an analysis of 1000 consecutive rotator cuff repairs. Am J Sports Med. 2014; 42(5): 1134-42.
Abtahi AM, Granger EK, Tashjian RZ, Abtahi AM, Granger EK, Tashjian RZ. Factors affecting healing after arthroscopic rotator cuff repair. World J Orthop. 2015; 6(2): 211-20.
Beason DP, Tucker JJ, Lee CS, Edelstein L, Abboud JA, Soslowsky LJ. Rat rotator cuff tendon-to-bone healing properties are adversely affected by hypercholesterolemia. J Shoulder Elb Surg [Internet]. 2014; 23(6): 867-72. Available in: http://dx.doi.org/10.1016/j.jse.2013.08.018
Carbone S, Gumina S, Arceri V, Campagna V, Fagnani C, Postacchini F. The impact of preoperative smoking habit on rotator cuff tear: cigarette smoking influences rotator cuff tear sizes. J Shoulder Elb Surg [Internet]. 2012; 21(1): 56-60. Available in: http://dx.doi.org/10.1016/j.jse.2011.01.039
Werthel JD, Vigan M, Schoch B, Ladermann A, Nourissat G, Conso C. Superior capsular reconstruction – A systematic review and meta-analysis. Orthop Traumatol Surg Res. 2021; 107(8): 103072.
Burnier M, Elhassan BT, Sanchez-Sotelo J. Surgical management of irreparable rotator cuff tears. J Bone Joint Surg Am. 2019; 101(17): 1603-12.
Chevalier Y, Pietschmann MF, Thorwachter C, Chechik O, Adar E, Dekel A, et al. Biodegradable spacer reduces the subacromial pressure: A biomechanical cadaver study. Clin Biomech [Internet]. 2017; 52: 41-8. Available in: https://doi.org/10.1016/j.clinbiomech.2017.12.008
Reeves JM, Singh S, Langohr GDG, Athwal GS, Johnson JA. An in-vitro biomechanical assessment of humeral head migration following irreparable rotator cuff tear and subacromial balloon reconstruction. Shoulder Elbow. 2020; 12(4): 265-71.
Senekovic V, Poberaj B, Kovacic L, Mikek M, Adar E, Markovitz E, et al. The biodegradable spacer as a novel treatment modality for massive rotator cuff tears: a prospective study with 5-year follow-up. Arch Orthop Trauma Surg. 2017; 157(1): 95-103.
Deranlot J, Herisson O, Nourissat G, Zbili D, Werthel JD, Vigan M, et al. Arthroscopic subacromial spacer implantation in patients with massive irreparable rotator cuff tears: clinical and radiographic results of 39 retrospectives cases. Arthroscopy. 2017; 33(9): 1639-44. doi: 10.1016/j.arthro.2017.03.029.
Piekaar RSM, Bouman ICE, van Kampen PM, van Eijk F, Huijsmans PE. The subacromial balloon spacer for massive irreparable rotator cuff tears: approximately 3 years of prospective follow-up. Musculoskelet Surg. 2020; 104(2): 207-14. doi: 10.1007/s12306-019-00614-1.
Singh S, Reeves J, Langohr GDG, Johnson JA, Athwal GS. The effect of the subacromial balloon spacer on humeral head translation in the treatment of massive, irreparable rotator cuff tears: a biomechanical assessment. J Shoulder Elbow Surg. 2019; 28(10): 1841-7. doi: 10.1016/j.jse.2019.03.036.
Lobao MH, Canham RB, Melvani RT, Abboud JA, Parks BG, Murthi AM. Biomechanics of biodegradable subacromial balloon spacer for irreparable superior rotator cuff tears: study of a cadaveric model. J Bone Joint Surg Am. 2019; 101(11): e49.
Patte D. Classification of rotator cuff lesions. Clin Orthop Relat Res. 1990; (254): 81-86.
Collin P, Matsumura N, Ladermann A, Denard PJ, Walch G. Relationship between massive chronic rotator cuff tear pattern and loss of active shoulder range of motion. J Shoulder Elbow Surg. 2014; 23(8): 1195-202. doi: 10.1016/j.jse.2013.11.019.
Hamada K, Yamanaka K, Uchiyama Y, Mikasa T, Mikasa M. A radiographic classification of massive rotator cuff tear arthritis. Clin Orthop Relat Res. 2011; 469(9): 2452-60.
Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987; (214): 160-4.
Teresa Hervás M, Navarro Collado MJ, Peiró S, Rodrigo Pérez JL, López Matéu P, Martínez Tello I. Versión española del cuestionario DASH. Adaptación transcultural, fiabilidad, validez y sensibilidad a los cambios. Med Clin (Barc). 2006; 127(12): 441-7.
Thong ISK, Jensen MP, Miró J, Tan G. The validity of pain intensity measures: what do the NRS, VAS, VRS, and FPS-R measure? Scand J Pain. 2018; 18(1): 99-107.
Hallock JD, Parsell DE, Field LD. Partial rotator cuff repair for massive tears rarely require revision surgery. Arthrosc Sports Med Rehabil. 2020; 3(1): e121-6. doi: 10.1016/j.asmr.2020.08.017.
Simovitch R, Flurin PH, Wright T, Zuckerman JD, Roche CP. Quantifying success after total shoulder arthroplasty: the minimal clinically important difference. J Shoulder Elbow Surg. 2018; 27(2): 298-305. doi: 10.1016/j.jse.2017.09.013.
Viswanath A, Drew S. Subacromial balloon spacer - Where are we now? J Clin Orthop Trauma. 2021; 17: 223-32. doi: 10.1016/j.jcot.2021.03.017.
Prat D, Tenenbaum S, Pritsch M, Oran A, Vogel G. Sub-acromial balloon spacer for irreparable rotator cuff tears: Is it an appropriate salvage procedure? J Orthop Surg (Hong Kong). 2018; 26(2): 2309499018770887.
Malahias MA, Brilakis E, Avramidis G, Antonogiannakis E. Satisfactory mid-term outcome of subacromial balloon spacer for the treatment of irreparable rotator cuff tears. Knee Surg Sports Traumatol Arthrosc. 2019; 27(12): 3890-6. doi: 10.1007/s00167-019-05485-4.
Wright MA, Abboud JA, Murthi AM. Subacromial balloon spacer implantation. Curr Rev Musculoskelet Med. 2020; 13(5): 584-91.
Metcalfe A, Parsons H, Parsons N, Brown J, Fox J, Gemperlé Mannion E, et al. Subacromial balloon spacer for irreparable rotator cuff tears of the shoulder (START:REACTS): a group-sequential, double-blind, multicentre randomised controlled trial. Lancet. 2022; 399(10339): 1954-63.
Dawson J, Fitzpatrick R, Carr A. Questionnaire on the perceptions of patients about shoulder surgery. J Bone Joint Surg Br. 1996; 78(4): 593-600.
Bakti N, Bhat M, Gulihar A, Prasad V, Singh B. Subacromial balloon interpositional arthroplasty for the management of irreparable rotator cuff tears: five-year results. Open Orthop J. 2019; 13(1): 89-96.
Familiari F, Nayar SK, Russo R, De Gori M, Ranuccio F, Mastroianni V, et al. Subacromial balloon spacer for massive, irreparable rotator cuff tears is associated with improved shoulder function and high patient satisfaction. Arthroscopy. 2021; 37(2): 480-6. doi: 10.1016/j.arthro.2020.09.048.
García Moreno J, Correa Bellido P, Salazar Aguilar JR, Pérez Correa JI, Montaner Alonso D, Rodrigo Pérez JL. Results after the application of biodegradable spacer balloons as a therapeutic option in non-repairable massive ruptures of the shoulder rotator cuff. Rev Esp Cir Ortop Traumatol. 2022; 66(1): 68-73. doi: 10.1016/j.recot.2020.11.004.
Basat HC, Kircil C, Armangil M, Demirts M. Treatment alternative for irreparable rotator cuff ruptures: Arthroscopic biodegradable balloon. Niger J Clin Pract. 2017; 20(8): 952-7.
Naggar L. Massive irreparable rotator cuff tears without arthropathy: the role of the balloon (biodegradable spacer) and comparison with other operative treatments. Orthop Procs. 2016; 98-B(Supp_21): 13.
Maman E, Safran O, Beyth S, Mozes G, Dekel A, Michael B, et al. Biceps tenotomy does not affect the functional outcomes of patients treated with spacer implantation due to massive irreparable rotator cuff tears. Open Orthop J. 2017; 11: 1577-84.
Malahias MA, Brilakis E, Avramidis G, Trellopoulos A, Antonogiannakis E. Arthroscopic partial repair with versus without biodegradable subacromial spacer for patients with massive rotator cuff tears: a case-control study. Musculoskelet Surg. 2021; 105(3): 247-55. doi: 10.1007/s12306-020-00649-9.
Johns WL, Ailaney N, Lacy K, Golladay GJ, Vanderbeck J, Kalore NV. Implantable subacromial balloon spacers in patients with massive irreparable rotator cuff tears: a systematic review of clinical, biomechanical, and financial implications. Arthrosc Sports Med Rehabil. 2020; 2(6): e855-72. doi: 10.1016/j.asmr.2020.06.011.
Gervasi E, Maman E, Dekel A, Markovitz E, Cautero E. Fluoroscopically guided subacromial spacer implantation for massive rotator cuff tears: two years of prospective follow-up. Orthop J Sports Med. 2021; 9(4): 2325967121993469.
Franchignoni F, Vercelli S, Giordano A, Sartorio F, Bravini E, Ferriero G. Minimal clinically important difference of the disabilities of the arm, shoulder and hand outcome measure (DASH) and its shortened version (QuickDASH). J Orthop Sports Phys Ther. 2014; 44(1): 30-9.
Kukkonen J, Kauko T, Vahlberg T, Joukainen A, Aarimaa V. Investigating minimal clinically important difference for Constant score in patients undergoing rotator cuff surgery. J Shoulder Elbow Surg. 2013; 22(12): 1650-5.
Lorente Gómez A, Vega Rodríguez RM, Álvarez R, Paniagua González A, Ruiz Díaz R, Ruiz Ibán MA, et al. Malos resultados a corto plazo del balón subacromial InSpace®. Resultados de 15 casos consecutivos con un año de seguimiento. Rev Esp Artrosc Cir Articul. 2017; 24(3): 197-203.
EVIDENCE LEVEL
III