Med Crit 2023; 37 (3)
Correlation between velocity time integral (VTI) of the left ventricular outflow tract (LVOT) and systolic volume variability (SVV) as predictors of volume responders in patients with shock in the Intensive Care Unit
Serna GJL, Sosa MMÁ
Language: Spanish
References: 15
Page: 195-197
PDF size: 188.58 Kb.
ABSTRACT
Introduction: currently, resuscitation is an essential part in the management of patients with shock, so multiple forms of monitoring have been described, either by minimally invasive hemodynamic mechanisms or by ultrasound evaluation, so it is interesting to know the relationship between each type of measurement.
Objective: to know if there is a correlation between the velocity time integral of the left ventricular outflow tract (DVTI) and systolic volume variability (SVV) as predictors of volume responders.
Material and methods: observational, cross-sectional comparative study in the intensive care unit, an analysis was performed to assess the relationship between VTI and SVV as volume responders in patients with shock.
Results: two relationships were carried out according to the data of the EV1000 type minimally invasive device and by ultrasonography, reporting the variability of systolic volume and delta of velocity time integral correspondingly, having a spearman correlation of 0.785 (p = 0.001) as well as the cardiac output measured by EV1000 and ultrasonography having a Spearman correlation of 0.688 (p = 0.002).
Conclusions: data analysed with this study allowed us to confirm the correlation between systolic volume variability and the delta velocity time integral as predictors of volume response in shock patients.
REFERENCES
Benes J, Giglio M, Brienza N, Michard F. The effects of goal-directed fluid therapy based on dynamic parameters on post-surgical outcome: a meta-analysis of randomized controlled trials. Crit Care. 2014;18(5):584.
Cecconi M, De Backer D, Antonelli M, Beale R, Bakker J, Hofer C, et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2014;40(12):1795-1815.
Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med. 2001;345(19):1368-1377.
Hadian M, Pinsky MR. Functional hemodynamic monitoring. Curr Opin Crit Care. 2007;13(3):318-323.
Biais M, Ehrmann S, Mari A, Conte B, Mahjoub Y, Desebbe O, et al. Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach. Crit Care. 2014;18(6):587.
Vincent JL, Ince C, Bakker J. Clinical review: circulatory shock--an update: a tribute to Professor Max Harry Weil. Crit Care. 2012;16(6):239.
Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002;121(6):2000-2008.
De Backer D, Biston P, Devriendt J, Madl C, Chochrad D, Aldecoa C, et al. Comparison of dopamine and norepinephrine in the treatment of shock. N Engl J Med. 2010;362(9):779-789.
Mahjoub Y, Lejeune V, Muller L, Perbet S, Zieleskiewicz L, Bart F, et al. Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study. Br J Anaesth. 2014;112(4):681-685.
Soliman RA, Samir S, el Naggar A, El Dehely K. Stroke volume variation compared with pulse pressure variation and cardiac index changes for prediction of fluid responsiveness in mechanically ventilated patients. Egypt J Crit Care Med. 2015;3(1):9-16.
de Waal EE, Rex S, Kruitwagen CL, Kalkman CJ, Buhre WF. Stroke volume variation obtained with FloTrac/Vigileo fails to predict fluid responsiveness in coronary artery bypass graft patients. Br J Anaesth. 2008;100(5):725-726.
Maguire S, Rinehart J, Vakharia S, Cannesson M. Technical communication: respiratory variation in pulse pressure and plethysmographic waveforms: intraoperative applicability in a North American academic center. Anesth Analg. 2011;112(1):94-96.
Michard F, Chemla D, Teboul JL. Applicability of pulse pressure variation: how many shades of grey? Crit Care. 2015;19(1):144.
Wang J, Zhou D, Gao Y, Wu Z, Wang X, Lv C. Effect of VTILVOT variation rate on the assessment of fluid responsiveness in septic shock patients. Medicine (Baltimore). 2020;99(47):e22702.
Vincent JL, De Backer D. Circulatory shock. N Engl J Med. 2013;369(18):1726-1734.