2021, Number 3
Vision-related quality of life in patients undergoing ACR-128 phakic intraocular lens implantation
Language: Spanish
References: 30
Page: 1-15
PDF size: 369.18 Kb.
ABSTRACT
Introduction: Phakic intraocular lens implantation to correct refraction defects has a number of advantages with respect to techniques such as corneal refractive surgery or clear lens extraction.Objective: Describe the changes in vision-related quality of life resulting from high myopia correction by ACR-128 phakic lens implantation.
Methods: A prospective longitudinal descriptive study was conducted with independent statistical analysis for each eye. The total sample was 91 eyes (46 right and 45 left) of 49 patients undergoing ACR-128 phakic lens implantation for myopia correction. The Pelli-Robson test was used to determine binocular contrast sensitivity at various spatial frequencies, and the NEI VFQ-25 questionnaire was applied before surgery (pre-test) and three months after surgery (post-test). Statistical analysis was based on the paired T-test with a significance level of 95%.
Results: Mean age was 28.73 ± 5.85 years. Female sex prevailed (71.43%). Significant differences were found in all the spatial frequencies of binocular contrast sensitivity between the pre- and postoperative periods (p < 0.01). Comparison of pre- and post-test results (retrospective assessment of presurgical quality of life) did not find any significant differences, indicating that there was no recalibration. Significant differences with respect to the post-test confirm the actual change in these patients' quality of life after surgery.
Conclusions: ACR-128 phakic lens implantation for high myopia correction improves vision-related quality of life without changes in its perception before and after surgery.
REFERENCES
Cárdenas T, Monteagudo K, Guerra M, Cruz D, Mariño O. Lentes fáquicas para la corrección de ametropías. Antecedentes y actualidad. Revista Cubana de Oftalmología. 2019 [acceso: 22/02/2020]; 31(2). Disponible en: Disponible en: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/609
Rodríguez B, Hernández Y, Llanes R, Veitía Z, Trujillo K, Guerra M. Escala NEI VFQ-25 como instrumento de medición de la calidad de vida relativa a la visión. Revista Cubana de Oftalmología. 2017 [acceso: 22/02/2020]; 30(1). Disponible en: Disponible en: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/510/html_266
González Iglesias Y, Zamora Galindo I, Fojaco Colina Y, Suárez Rodríguez B, García Álvarez H. Comportamiento de la calidad de vida relativa a salud antes y después de la cirugía de catarata. Rev Cubana Oftalmol. 2007 [acceso: 02/09/2020]; 20(1). Disponible en: Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S086421762007000100004&lng=es
Trujillo K, Valdés G, Hormigó I, Arrieta H, Cuan Y. Calidad visual y calidad de vida en pacientes operados de catarata mediante facoemulsificación. Revista Cubana de Oftalmología. 2019 [acceso: 22/02/2020]; 32(1). Disponible en: Disponible en: http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/70
Rodríguez Suárez B, Ramos Pereira Y, Montero Díaz E, Cárdenas Díaz T, Pérez Candelaria E, Duarte Iribe N. Calidad de vida según la escala NEI VFQ-25 en la cirugía facorrefractiva de pacientes hipermétropes présbitas. Rev Cubana Oftalmol. 2018 [acceso: 21/09/2020]; 31(2). Disponible en: Disponible en: http://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/639/html_340
Rodríguez B, Duarte N, Hormigó I, Méndez A, García J. Calidad de vida relativa a la función visual en pacientes operados de catarata. Revista Cubana de Oftalmología. 2019 [acceso: 22/02/2020]; 32(1). Disponible en: Disponible en: http://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/698/html_374
Ruiz Rodríguez Y, Hernández Silva JR, Curbelo Cunill L, Capote Cabrera A, Pérez Candelaria E, Ibarra Ávila R. Efectividad de los lentes fáquicos Artisan en la corrección de la alta miopía. Rev Cubana Oftalmol. 2010 [acceso: 22/02/2020]; 23(2):288-98. Disponible en: Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-21762010000200011&lng=es
Ruiz Rodríguez Y, Capote Cabrera A, Pérez Candelaria Eneida, Hernández Silva JR, Curbelo Cunill L. Experiencia con los lentes fáquicos Artiflex como opción correctiva de la alta miopía. Rev Cubana Oftalmol. 2010 [acceso: 22/02/2020]; 23(1):67-77. Disponible en: Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-21762010000100007&lng=es
Cárdenas T, Li Fengqi, Pérez R, Cruz D, Monteagudo K, Estévez Y. Resultados visuales en la corrección de alta miopía con implante de lente fáquica ACR-128. Revista Cubana de Oftalmología. 2019[acceso: 22/02/2020]; 32(2). Disponible en: Disponible en: http://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/611
Cárdenas T, Li F, Guerra M, Fumero F, Sánchez L. Efecto de la lente fáquico ACR-128 sobre tensión ocular y endotelio corneal en altas miopías. Revista Cubana de Oftalmología. 2019 [acceso: 22/02/2020]; 32(2). Disponible en: Disponible en: http://revoftalmologia.sld.cu/index.php/oftalmologia/article/view/612